Go to page of
Similar user manuals
-
Power Supply
Minuteman UPS MCP-E
32 pages 0.63 mb -
Power Supply
Minuteman UPS AT1600, GS1600 (1600VA)
14 pages 0.18 mb -
Power Supply
Minuteman UPS UPS
24 pages 0.44 mb -
Power Supply
Minuteman UPS CPE 2000
17 pages 0.64 mb -
Power Supply
Minuteman UPS ED6000RMXFMR
1 pages 0.74 mb -
Power Supply
Minuteman UPS MCP 3000
24 pages 0.86 mb -
Power Supply
Minuteman UPS Enterprise Plus Series
32 pages 1.79 mb -
Power Supply
Minuteman UPS SentryII UPS
37 pages 1.71 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Minuteman UPS Endeavor, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Minuteman UPS Endeavor one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Minuteman UPS Endeavor. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Minuteman UPS Endeavor should contain:
- informations concerning technical data of Minuteman UPS Endeavor
- name of the manufacturer and a year of construction of the Minuteman UPS Endeavor item
- rules of operation, control and maintenance of the Minuteman UPS Endeavor item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Minuteman UPS Endeavor alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Minuteman UPS Endeavor, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Minuteman UPS service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Minuteman UPS Endeavor.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Minuteman UPS Endeavor item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
User's Manual Endeavor Series Battery Packs[...]
-
Page 2
1 © Copyright 2006 English 1 . Introduction 2 2 . Controls and Indicators 6 3. Installation 7 4. Operation 14 5 . T roubleshooting 15 6 . Replacing the Battery 16 7 . Obtaining Service 20 8 . Specifications 21 9 . Limited Product W arranty 22[...]
-
Page 3
2 English IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS ! Thank you for purchasing this power protection product. It has been designed and manufactured to provide many years of trouble free service. Please read this manual before installing your Endeavor Series Battery Pack, models EDBP24XL, EDBP48XL, EDBP72XL as it provides important inf[...]
-
Page 4
3 English W ARNING: Risk of Electrical Shock. Hazardous live parts inside these Battery Packs are energized from the battery even when the AC input is disconnected. CAUTION! T o de-energize the Battery Pack: 1. If the UPS is on press and release the Off button. 2. Disconnect the UPS and the Battery Pack from the wall outlet. 3. Turn off the DC brea[...]
-
Page 5
4 English NOTICE: This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the speci- fications in Subpart J of Part 15 of FCC Rules and the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference of the Canadian Department of Communications. These[...]
-
Page 6
5 English Receiving Inspection After removing your Battery Pack from its carton, it should be inspected for damage that may have occurred in shipping. Immediately notify the carrier and place of purchase if any damage is found. Warranty claims for damage caused by the carrier will not be honored. The packing materials that your Battery Pack was shi[...]
-
Page 7
6 English The Charger Active (green) LED illuminates in a steady st ate when the Charger is on. The Charger Active LED will extinguish when there is no acceptable AC present. The DC Breaker On (green) LED illuminates in a steady state when the DC breaker is in the On position. The DC Breaker On LED will extinguish when the DC breaker is in the Off [...]
-
Page 8
7 English INST ALLA TION PLACEMENT These Battery Packs are intended to be install in a temperature controlled environment that is free of conductive contaminants. Select a location which will provide good air circulation for the Battery Pack at all times. Avoid loca- tions near heating devices, water or excessive humidity , or where the Battery Pac[...]
-
Page 9
8 English RACKMOUNT CONFIGURA TION The Battery Pack comes with mounting brackets for the standard 19" (46.5cm) rack. The mounting brackets to fit a 23" (59.2cm) standard rack are also avail- able. The screws for mounting the Battery Pack to the rack are not included (screw size varies with rack size). 1. Locate the mounting bracket screw [...]
-
Page 10
9 English T OWER CONFIGURA TION The tower configuration allows the user to install the Battery Pack in the up- right position next to the UPS and the tower computer . The tower brackets are provided with the Battery Pack. W ARNING: Use two or more people when installing the Battery Pack. Use CAUTION, the Battery Pack is extremely heavy . 1. Once th[...]
-
Page 11
10 W ALLMOUNT CONFIGURA TION (continued) 2. Align the mounting brackets with the mounting bracket screw holes and attach with the six retaining screws. 3. Use the template to mark the screw hole position on the wall. CAUTION, you should always were protective gear for your hands and eyes when operating power tools. 4. Attach the four ret aining scr[...]
-
Page 12
11 CONNECTING THE BA TTER Y P ACK (QUALIFIED SERVICE PERSONNEL ONL Y) NOTE: If you are using these Battery Packs with the Endeavor series UPS, the UPS must be configured so that the UPS will report the correct estimated runtime in the SentryPlus software and to make the Battery capacity bar graph LEDs display properly . See the SentryPlus software [...]
-
Page 13
12 English CHARGING THE BA TTER Y The Battery Packs will charge the internal batteries whenever the Battery Pack is connected to an AC source and there an acceptable AC voltage present. It is recommended that the Battery Packs be charged for a minimum of 4 hours before use. The Battery Pack maybe used immediately , however , the “On- Battery” r[...]
-
Page 14
13 English 7. Before connecting the Battery Pack to an AC Source, verify that the Battery Pack is set for the proper input voltage. Set the dipswitch on the rear panel of the Battery Pack to the appropriate input voltage. Connect the input power cord with the NEMA 5-15P Plug into the AC Inlet on the first Battery Pack. 8. Connect the Daisy Chain po[...]
-
Page 15
14 English English SYSTEM OVERVIEW These Battery Packs will extend the runtime capabilities of the UPS. These Battery Packs have internal chargers to properly maintain the internal batter- ies. The charger will operate with 1 15V AC or 230V AC depending on the dipswitch setting. The Battery Pack will charge the batteries with the DC circuit breaker[...]
-
Page 16
15 English Possible Cause Symptom What T o Do 1. Plug the input power cord into the AC wall outlet. 2. Once commercial power is available recheck the LED. 3. Check the circuit breaker at the service panel to see if it is tripped. 4. Call for Service. 1. The input power cord is not plugged into the AC wall outlet. 2. No commercial power available. 3[...]
-
Page 17
16 English REPLACING THE BA TTER Y W ARNING! This Battery Pack contains potentially hazardous voltages. Do not attempt to disassemble the Battery Pack beyond the battery replacement procedure. These Battery Packs contain no user serviceable parts. Repairs and Battery replacement must be per- formed by QUALIFIED SERVICE PERSONNEL ONL Y . Do not open[...]
-
Page 18
17 English BA TTER Y REPLACEMENT PROCEDURE (QUALIFIED SERVICE PERSONNEL ONL Y) PLEASE READ THE CAUTIONS AND W ARNINGS BEFORE A TTEMPTING TO REPLACE THE BA TTERIES Hot-swappable batteries mean that the batteries can be replaced without powering down the whole UPS system. NOTE: If there is a power interruption while replacing the hot-swappable batter[...]
-
Page 19
18 English 15. Grasp the other battery pull tab and gently pull the battery module out of the Battery Pack and set on the floor . (FIG . 4) NOTE: Use Caution, the battery modules are heavy . 16. Disconnect the battery positive (red) wires. 17. Disconnect the battery negative (black) wires. 18. Disconnect the battery jumper wires. 19. Remove the old[...]
-
Page 20
19 English FIG . 2 FIG . 3 FIG . 4[...]
-
Page 21
20 English IF THE UPS REQUIRES SERVICE 1. Use the TROUBLESHOOTING section to eliminate obvious causes. 2. V erify there are no circuit breakers tripped. A tripped circuit breaker is the most common problem. 3. Call your dealer for assistance. If you cannot reach your dealer , or if they cannot resolve the problem call or fax MINUTEMAN T echnical Su[...]
-
Page 22
21 English Battery T ype 24VDC T ypical Recharge T ime 50 or 60 Hz, +/-6Hz, autosensing 1 15V AC: 90 - 130V AC (230V AC: 180 - 260V AC) 2.6 Amps 27.6VDC +/-5% Frequency Limits DC V oltage V oltage Range EDBP24XL Model Number SYSTEM SPECIFICA TIONS AC Current Format Rack/T ower Convertible CHARGER OUTPUT CHARGER INPUT Number of Phases Single (1 ∅ [...]
-
Page 23
22 English Para Systems Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship for a period of three years from the date of purchase. For equip- ment sites within the United S t ates and Canada, this warranty covers rep air or replacement of defective equi[...]
-
Page 24
23 English EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL P ARA SYSTEMS BE LIABLE FOR DIRECT , INDIRECT , SPECIAL, INCIDENT AL, OR CONSEQUEN- TIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT , EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. S pecifically , Para Sys- tems is not liable for any costs, such as lost profits or revenue, loss of equip-[...]
-
Page 25
24 English Notes:[...]
-
Page 26
Para Systems, Inc. 1455 Lemay Dr . Carrollton, TX 75007 Phone: 1-972-446-7363 Fax: 1-972-446-901 1 Internet: minutemanups.com UPS Sizing: sizemyups.com P/N 34000275[...]