Mitsubishi Electronics F800 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Mitsubishi Electronics F800, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsubishi Electronics F800 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Mitsubishi Electronics F800. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Mitsubishi Electronics F800 should contain:
- informations concerning technical data of Mitsubishi Electronics F800
- name of the manufacturer and a year of construction of the Mitsubishi Electronics F800 item
- rules of operation, control and maintenance of the Mitsubishi Electronics F800 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsubishi Electronics F800 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsubishi Electronics F800, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsubishi Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsubishi Electronics F800.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsubishi Electronics F800 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INVERTER FR-A800/F800 Safety S top Function Instruction Manual CONTENTS 1. GENERAL DESCRIPTION .. .......................................... 2 2. INSTALLATION AND WIRING ...................................... 3 3. EXAMPLE OF SAFETY SYSTEM CONFIGURATION .... 7 4. TEST AND CHECKING FAILURE ............................... 10 5. SAFETY PARAMETERS OF FR[...]

  • Page 2

    1 Compliance with the EU Machin ery Directive – Functional Safety WA R N I N G  Any misuse of saf ety function could lead to per sonal injury or death, proper ty damage, or economic loss. T o ensure that the system complies fully with requirement of safety , make a system-level risk assessment. Mit subishi Electric Co. cannot assume responsibi[...]

  • Page 3

    2 GENERAL DESCRIP TION 1 GENERAL DESCRIPTION Features Mitsubishi FR-A800/F800 safety stop function prevents a dr ive fr om supplying rotatio nal energy to motor s. Dual safety channels ‘S1’ and ‘S2’ cut o ff th e gate-drive powe r for IGBT to turn off. Fig.1 FR-A800 /F800 safety stop functio n diagram Standards Mitsubishi FR-A800/F800 safet[...]

  • Page 4

    INSTALLATION AND WIRING 3 2 INST ALLA TION AND WIRING Installation Mitsubishi FR-A800/F8 00 safety stop function shoul d be used under following cond ition and environment. T able.1 The condition and envir onment for using safety stop functi on  The ND and HD ratings can be selecte d only for the FR-A800.  T emperature applicable for a [...]

  • Page 5

    4 INSTALLATION AND WIRING ● Wiring The safety related terminals are de scribed in T a ble.2 and T abl e.3 T able.2 The safety relate d terminals  S pecifications for conforming safety standards.  ON: The transistor is conducted. OF F: The transistor is not conducted. CAUTION  In order to meet safety stop, an approved safety relay u[...]

  • Page 6

    INSTALLATION AND WIRING 5 T able.3 T ruth t able of safety relat ed signals  ON: The transistor is conducted. OFF: The transistor is not conducted.  When not using the safety stop function, short across terminals S1 and PC, S2 and PC, a nd SIC and SD to use the inverter . (In the initial status, terminals S1 and PC, S2 and PC, and SIC a[...]

  • Page 7

    6 INSTALLATION AND WIRING ● Wire and ferrule specification T able.4 Wire and ferrule spec ification  Ferrules and tools are distributed by Phoenix Contact. ● Jumper cable The jumper cable between S1,S2 and PC termin al between SIC and SD terminal has been inst alled in the factory as shown in Fig.2. Fig.2. Short wire Before conne cting sa[...]

  • Page 8

    EXAMPLE OF SAFETY SYSTEM CONFIGURATION 7 3 EXAMPLE OF SAFETY SY STEM CONFIGURA TION ● FR-A800/F800 configuration exa mple  If the control logic is SINK logic, the common terminal is terminal SD. Fig.3 Safety system example with FR- A800/F800 NOTE • When starting up the system’ s operation, press the RESET switch to reset the safety stop[...]

  • Page 9

    8 EXAMPLE OF SAFETY SYSTEM CONFIGURATION ● Multiple inverter configuration exam ple Fig.4 When using multiple safety stop func tion inverters (FR-A800/F800) NOTE • Some models cannot be used together because thei r control logics are different. Refer to the SAFETY STOP FUNCTION MANUAL of each model. S 1 S 2 PC FR-A800/F800 SO R/L1 S/L2 T/L3 IGB[...]

  • Page 10

    EXAMPLE OF SAFETY SYSTEM CONFIGURATION 9 ● Safety controller configuration exa mple Fig.5 Safety system example with FR- A800/F800 NOTE • When starting up the system’ s operation, press the RESET switch to reset the safety stop function first. • In the above configuration, af ter reset of emergency stop button, drive will be in safe-state u[...]

  • Page 11

    10 TEST AND CHECKING FAILURE 4 TEST AND CHECKING F AIL URE I/O status and failure FR-A800/F800 safety re lated I/O status obeys the following truth t able. T able.5 T ruth t able of safety related signals  ON: The transistor is conducted. OF F: The transistor is not conducted.  When not using the safety stop function, short across termi[...]

  • Page 12

    SAFETY PARAMETERS OF FR-A800/F800 11 Diagnostic If the failure detected, FR-A800/F800 output ala rm signal and i ndicate ‘E.SAF’ at the display . In case of FR-A800/F800 output the alar m, please take following action. 1) Check the S1-SIC and S2-SIC input sign al logic is the same. If these are differe nt lo gic, collect the input signal and re[...]

  • Page 13

    12 REVISIONS Print Date Manual Number Revision Apr . 2013 BCN-A23228-001(E) First edition Jun. 2013 BCN-A23228-001-A(E) ● Multiple inverter configuration example Jul. 2014 BCN-A23228-001-B(E) Compatibility with the FR-F800 series Modification BCN-A23228-001-B(E)[...]

  • Page 14

    HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAP AN MITSUBISHI ELECTRIC EUROP E EUROPE B.V . German Branch Gothaer S traße 8 D-40880 Ratingen Phone: +49 (0) 21 02 / 486-0 Hotline: +49 2102 1805 000-76 5 /-766 Fax: +49 (0) 21 02 / 4 86-1 12 0 e mail: megfa-ma il@meg.mee.com www .mitsubishi-automatio n.com MITSUBISHI EL[...]