A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Mitsubishi Electronics FR-A500L, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsubishi Electronics FR-A500L one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Mitsubishi Electronics FR-A500L. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Mitsubishi Electronics FR-A500L should contain:
- informations concerning technical data of Mitsubishi Electronics FR-A500L
- name of the manufacturer and a year of construction of the Mitsubishi Electronics FR-A500L item
- rules of operation, control and maintenance of the Mitsubishi Electronics FR-A500L item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsubishi Electronics FR-A500L alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsubishi Electronics FR-A500L, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsubishi Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsubishi Electronics FR-A500L.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsubishi Electronics FR-A500L item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
- INSTR UCTION MANU AL - FR-A560L-375K~900K-NA HIGH PERFORMANCE HIGH-FUNCTIONS LARGE CAP A CITY INVER TER FR-A 500L MITSUBISHI ELECTRIC Supplementary Manual Refer to Operation/Instruction Manual for FR-A500L.[...]
-
Page 2
A - 1 Thank you for choosing this Mitsubishi Larg e Capacity Inv erter. This instr uction manual gi ves handling information and precautions for use of this equipment. Incorrect handli ng might cause an unex pected f ault. Before using the inv erter, please read this manual carefully to use the equipment to i ts optimum. This manual describes the p[...]
-
Page 3
A - 2 SA FETY INSTRUCTIONS 1. Electric Shock Prevention WA RNING z W hile power is on or when the inverter is running, do not open the front door. You may get an electric shock . z Do not run the inverter with the fr ont door opened. Contact with the exposed high-voltage ter m inals or charging part of circ uitry w ill caus e an electric s ho[...]
-
Page 4
A - 3 4. A dditional instructi ons Also note the following points to prevent an ac cidental failur e, injury, electric shoc k, etc.: (1) Transportati on and i nstal l a ti on CA UTION z W hen carrying products, use c orrect lif ting gear to prevent inj ury. z Ensure that installation position and m aterial c an withstand the weight of the inv[...]
-
Page 5
A - 4 (4) Operation CA UTION z W hen y ou have c hosen the re try function, stay away from the equipm ent as it will restart suddenly after an alar m s top. z The [ST OP] k ey is valid only w hen the appropr iate function s etting has been made. Pr epare an emer gency stop switch separately. z Make s ure that the star t s ignal is of f bef[...]
-
Page 6
CONTENTS 1 OUTL INE ..................................................................................................................... .................... 1 1.1 Pre-Operation Inform ation ................................................................................................... ........... 1 1.1.1 Precautions f or operation ...........[...]
-
Page 7
1 CHAPTER 1 OUTLINE This chapter giv es information on the basic "outline" of this product. Alway s read the instructions in this chapter before using the equipment. 1.1 Pre-Operation Information ・・・・・・・・・・・・・・・・・・・ 1 1.2 Basic Configuration ・・・・・・・・・・・・・・・・・・・・[...]
-
Page 8
1.1 Pre-Operation Information OUTL I NE 1 1.1.1 Precautions for operation Incorrec t handling m ight cause the inverter to operate im properly, its life to be reduc ed consider ably , or at the worst, the inverter to be damaged. Handle the inver ter properly in accordance with the inf orm ation in each section as well as the precautions and ins tru[...]
-
Page 9
1.2 Basic Configuration OUTLIN E 2 1.2.1 Basic configuration The following devices are required to operate the inverter. Proper peripheral devices must be selected and correct connections made to ensure proper operation. Incorrect system configuration and connections can cause the inverter to operate improperly, its life to be reduced considerably,[...]
-
Page 10
2 CHAPTER 2 INSTALLATION AND WIRING This chapter giv es information on the basic "installation and wiring" of this product. Alway s read the instructions in this chapter before using the equipment. 2.1 Installation ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3 2.2 Wiring ・・・・・[...]
-
Page 11
2.1 Installation INSTALLATION AND WIRING 3 2.1.1 Instructions for installation 1) Handle the unit carefully. The inverter uses plastic parts. Handle it gently to protect it from damage. Also, hold the unit with even strength and do not apply too much strength to the front cover alone. 2) Install the inverter where it is not subjected to vibration. [...]
-
Page 12
INSTALLATION A ND WIRING 4 3) Note on am bient tem peratures FR-A560L-530 ∼ 900K 40 ° C at 5cm (1.97 inch) FR-A560L-375, 450K[...]
-
Page 13
2.2 Wiring INSTALLATION A ND WIRING 5 2.2.1 Terminal connection diagram[...]
-
Page 14
INSTALLATION A ND WIRING 6 ( 1 ) Description of main circuit terminals Ty pe Sy mbol Term in al Nam e Description R, S, T <L 1 , L 2 , L 3 > AC power input Connect to the com m ercial power supply. Keep thes e term inals unc onnected when using the hi gh power factor convert er (MT-HC). U, V, W Invert er output Connect a t hree-phase squirrel[...]
-
Page 15
INSTALLATION AND WIRING 7 Type Symbol Terminal Name Description 10E 10VDC, permissible load current 10mA 10 Frequency setting power supply 5VDC, permissible load current 10mA When the frequency setting potentiometer is connected in the factory-set state, connect it to terminal 10. When it is connected to terminal 10E, change the input specification[...]
-
Page 16
INSTALLATION AND WIRING 8 2.2.2 Wiring of the main circuit ( 1 ) Wiring instructions 1) Power must not be applied to the output terminals (U, V, W) of the inverter. Otherwise the inverter will be damaged. 2) After wiring, wire off-cuts must not be left in the inverter. Wire off-cuts can cause an alarm, failure or malfunction. Always keep the invert[...]
-
Page 17
INSTALLATION A ND WIRING 9 ( 2 ) Terminal block lay out In the main c ircuit of the inverter, the term inals are arranged as shown below: FR-A560L-530K ∼ 900K Left Si de Front Right S ide MAIN CIRCUI T TERMINA L (Detail) 75 40 17.5 40 17.5 17.5 Units <mm>[...]
-
Page 18
INSTALLATION A ND WIRING 10 FR-A560L-375K, 450K P0 W V U 108 96 96 96 104 P1 N P TSR P0 W V U P1 N P T S R 156 96 96 152 430 505 210 230 155 Rg[ p l 4 - 30 500 1100 1900 (Bottom View) 4-φ 30 U, V, W, P0 P1, P, N [q R, S, T 45 37.5 37.5 40 17.5 40 17.5 17.5 40 35 35 40 17.5 40 [q Units < mm > TERMINAL ( Det ail ) TERMINAL ( Det ail )[...]
-
Page 19
INSTALLATION A ND WIRING 11 ( 3 ) Connection of the power supply and motor ( 4 ) Connecting the control circuit to a power supply separately from the main circuit If the magnetic contac tor (MC) in the inverter power supply is opened w hen the protec tive circuit is operated, the inverter control circuit power is lost and the alarm output s ignal c[...]
-
Page 20
INSTALLATION AND WIRING 12 2.2.3 Wiring of the control circuit ( 1 ) Wiring instructions 1) Terminals SD, SE and 5 are common to the I/O signals and isolated from each other. These common terminals must not be connected to each other or earthed. 2) Use shielded or twisted cables for connection to the control circuit terminals and run them away from[...]
-
Page 21
INSTALLATION A ND WIRING 13 ( 3 ) Changing the control logic The input s ignals are set to s ink logic f or the NA vers ion, and to sourc e logic for the EC version. To change the control logic, the connector on the back of the contr ol circuit ter m inal block m ust be m oved to the other position. (The output s ignals m ay be used in either the s[...]
-
Page 22
INSTALLATION A ND WIRING 14 4) Sink logic type • In this logic, a s ignal switches on when a current f lows out of the cor responding s ignal input term inal. Ter minal SD is com m on to the contac t input signals. T erm inal SE is c om mon to the open c ollector output signals. R R STF STR SD RUN SU SE 1 2 9 8 R R R R DC24V AX40 Curre nt • W h[...]
-
Page 23
INSTALLATION A ND WIRING 15 5) Source logic ty pe • In this logic, a s ignal switches on when a current f lows into the corr esponding signal input term inal. Ter minal PC is com m on to the contac t input signals . T erm inal SE is com m on to the open c ollector output signals. DC24V RUN SU SE 1 2 9 8 R R R R AX80 PC STF STR R R Current • W h[...]
-
Page 24
INSTALLATION A ND WIRING 16 2.2.4 Connection to the PU connector ( 1 ) When connecting the operation panel or parameter unit using a connection cable <Recommended cable co nnector> • Param eter unit connec tion cable (FR- CB2) (option) or the f ollowing connector and c able. • Connector: RJ45 c onnector Exam ple: 5-554720-3, Nippon AMP ?[...]
-
Page 25
INSTALLATION A ND WIRING 17 2.2.5 Design information 1) For com m ercial power supply-inverter switch-over operation, pr ovide electrical and m ec hanical interloc ks for MC1 and MC2 des igned for c om m ercial power supply-inverter switch- over. W hen there is a com m erc ial power supply-inverter switch- over circ uit as shown below, the inverter[...]
-
Page 26
3 CHAPTER 3 OPERATION This chapter provides the basic "operation" information for use of this product. Alway s read this chapter before using the equipment. 3.1 Pre-Operation Information ・・・・・・・・ Refer to FR-A540L/ A560L 3.2 Operation ・・・・・・・・・・・・・・・・・・・・・・ Refer to FR-A540L/ A56[...]
-
Page 27
4 CHAPTER 4 PARAMETERS This chapter explains the "parameters" of this product. Alway s read the instructions before using the equipment. 4.1 Parameter List ・・・・・・・・・・・・・・・・・・ 18 4.2 Parameter Function Details ・・・・・・・ Refer to FR-A540L/ A560L Note: By m ak ing param eter s ettings, you can [...]
-
Page 28
4.1 Parameter List PARAMETERS 18 PARAMETER F unc - tion Parameter Number Name Setting Range Minimum Setting Increments Factory Setting Refer To Page: <Note9> 0 Torque boost (Note 1) 0 to 30% 0.1% 1% 48 1 Maximum frequency 0 to 60Hz 0.01Hz 60Hz 49 2 Minimum frequency 0 to 120Hz 0.01Hz 0Hz 49 3 Base frequency 0 to 400Hz 0.01Hz 60Hz<50Hz> [...]
-
Page 29
PARAMETERS 19 F unc - tion Parameter Number Name Setting Range Minimum Setting Increments Factory Setting Refer To Page: <Note9> 52 DU/PU main display data selection 0, 5 to 14, 17, 18, 20, 23, 24, 25, 100 1 0 67 53 PU level display data selection 0 to 3, 5 to 14, 17, 18 1 1 67 54 FM terminal function selection 1 to 3, 5 to 14, 17, 18, 21 1 1[...]
-
Page 30
PARAMETERS 20 F unc - tion Parameter Number Name Setting Range Minimum Setting Increments Factory Setting Refer To Page: <Note9> 107 V/F4 (fourth frequency voltage) (Note 1) 0 to 1000V 0.1V 0 98 108 V/F5 (fifth frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 98 5-point flexible V/F characteristics 109 V/F5 (fifth frequency voltage) (Note 1) [...]
-
Page 31
PARAMETERS 21 Func - tion Parameter Number Name Setting Range Minimum Setting Increments Factory Setting Refer To Page: <Note9> 150 Output current detection level 0 to 200% 0.1% 150% 120 151 Output current detection period 0 to 10 sec 0.1 sec 0 120 152 Zero current detection level 0 to 200% 0.1% 5.0% 121 Current detection 153 Zero current det[...]
-
Page 32
PARAMETERS 22 Func - tion Parameter Number Name Setting Range Minimum Setting Increments Factory Setting Refer To Page: <Note9> 200 Programmed operation minute/second selection 0 to 3 1 0 131 201 Program set 1 1 to 10 0 to 2: Rotation direction 0 to 400, 9999:Frequency 0 to 99.59: Time 1 0.1Hz Minute or second 0 9999 0 131 211 Program set 2 1[...]
-
Page 33
PARAMETERS 23 Func - tion Parameter Number Name Setting Range Minimum Setting Increments Factory Setting Refer To Page: <Note9> 278 Brake opening frequency (Note 3) 0 to 30Hz 0.01Hz 3Hz 142 279 Brake opening current (Note 3) 0 to 200% 0.1% 130% 142 280 Brake opening current detection time (Note 3) 0 to 2 sec 0.1 sec 0.3 sec 142 281 Brake oper[...]
-
Page 34
5 CHAPTER 5 PROTECTIVE FUNCTIONS This chapter ex plains the "protectiv e functions" of this product. Alway s read the instructions before using the equipment. 5.1 Errors (Alarms) ・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 24 5.2 Troubleshooting ・・・・・・・・・・・・・・・・・?[...]
-
Page 35
5.1 Errors (Alarms) PROTECTIVE FUNCTIONS 24 If any fault has occurred in the inverter, the corresponding protective function is activated and the error (alarm) indication appears automatically on the PU display. When the protective function is activated, refer to "5.2 Troubleshooting" and clear up the cause by taking proper action. If an [...]
-
Page 36
PROTECTIVE FUNCTIONS 25 Operatio n Panel Display (FR-DU04) Paramete r Unit (FR-PU04) Name Description E. GF Ground Fault Output side ground fault overcurrent protection This function stops the inverter output if a ground fault occurs in the inverter's output (load) side and a ground fault current flows. A ground fault occurring at low ground r[...]
-
Page 37
PROTECTIVE FUNCTIONS 26 Operatio n Panel Display (FR-DU04) Paramete r Unit (FR-PU04) Name Description E.CTE Operation panel power short circuit When the operation panel power (P5S of the PU connector) is shorted, this function shuts off the power output. At this time, the operation panel (parameter unit) cannot be used and RS-485 communicati[...]
-
Page 38
PROTECTIVE FUNCTIONS 27 Main circuit error [E,15] details Name Detail s Brake unit cooling f in overheating The inverter output w ill stop if the brake unit' s cooling fi n temperat ure rises above the specif ied value. Control board am bient tem perature error The inverter output will stop if the am bient tem perature of t he cont rol board r[...]
-
Page 39
PROTECTIVE FUNCTIONS 28 ● ● ● ● To know the operating status at the occurrence of alarm W hen any alarm has oc curred, the dis play automatically switches to the indication of the c orres ponding protective f unction (err or). By pressing the [MODE] k ey at this point without res etting the inverter, the display shows the output fr equency.[...]
-
Page 40
PROTECTIVE FUNCTIONS 29 5.1.3 Alarm code output By setting Pr. 76 "alarm code output selection", an alarm definition can be output as a 4-bit digital signal. This signal is output from the open collector output terminals equipped as standard on the inverter. Correlations between alarm definitions and alarm codes are as follows. Output Ter[...]
-
Page 41
5.2 Troubleshooting PROTECTIVE FUNCTIONS 30 If any function of the inverter is lost due to occurrence of a fault, clear up the cause and make correction in accordance with the following procedure. Contact your sales representative if the corresponding fault is not found below, the inverter has failed, parts have been damaged, or any other fault has[...]
-
Page 42
PROTECTIVE FUNCTIONS 31 Operation Panel Display Check Point Remedy Brake unit cooling fin overheating Is the usage frequency of the brake unit appropriate? Are the cooling fins clogged? Is there any error in the inverter unit cooling fan? Reduce the load GD 2 . Reduce the braking frequency. Clean the cooling fins. Replace the cooling fan. Control b[...]
-
Page 43
PROTECTIVE FUNCTIONS 32 5.2.2 Faults and check points POINT: Check the corresponding areas. If the cause is still unknown, it is recommended to initialize the parameters (return to factory settings), re-set the required parameter values, and check again. ( 1 ) Motor remains stopped. 1) Check the main circuit · Check that a proper power supply volt[...]
-
Page 44
PROTECTIVE FUNCTIONS 33 ( 5 ) Motor current is large. · Check that the load is not too heavy. · Check that the torque boost (Pr. 0, Pr. 46, Pr. 112) setting is not too large. ( 6 ) Speed does not increase. · Check that the maximum frequency (Pr. 1) setting is correct. · Check that the load is not too heavy. (In agitators, etc., load may become [...]
-
Page 45
5.3 Pre cautions for Maintenance and Inspection PROTECTIVE FUNCTIONS 34 The transistorized inverter is a static unit mainly consisting of semiconductor devices. Daily inspection must be performed to prevent any fault from occurring due to adverse influence by the operating environment, such as temperature, humidity, dust, dirt and vibration, change[...]
-
Page 46
PROTECTIVE FUNCTIONS 35 5.3.4 Insulation resistance test using megger 1) Before perfor m ing the insulation resis tance test us ing a megger on the external c ircuit, disc onnect the cables f rom all term inals of the inverter s o that the test voltage is not applied to the inver ter. 2) For the continuity test of the c ontrol circ uit, use a teste[...]
-
Page 47
PROTECTIVE FUNCTIONS 36 Daily and Periodic Inspection Interval Periodic Area of Inspec - tion Inspection Item Description Daily 1 year 2 years Method Criterion Instrument Inverter module, Converter module Check resistance across terminals. ¡ Disconnect cables from inverter and measure across terminals R, S, T, P, N and U, V, W, P, N <L 1 , L 2 [...]
-
Page 48
PROTECTIVE FUNCTIONS 37 z Checking the inv erter and conv erter modules <Preparation> (1) Disc onnect the external power s upply cables (R, S, T ) <L 1 , L 2 , L 3 > and motor cables (U, V, W ) . (2) Prepare a tes ter. (Us e 100 Ω range.) <Checking method> Change the polarity of the tester alternately at the inverter term ina[...]
-
Page 49
PROTECTIVE FUNCTIONS 38 5.3.6 Replacement of parts The inverter consists of many electronic parts such as semiconductor devices. The following parts may deteriorate with age because of their structures or physical characteristics, leading to reduced performance or failure of the inverter. For preventive maintenance, the parts must be changed period[...]
-
Page 50
PROTECTIVE FUNCTIONS 39 5.3.7 Measurement of main circuit voltages, currents and pow er ● ● ● ● Measurement of v oltages and currents Since the voltages and cur rents on the inverter power supply and output sides include harm onics , accurate m eas urem ent depends on the instr uments used and circ uits m easured. W hen instrum ents f or co[...]
-
Page 51
PROTECTIVE FUNCTIONS 40 Measuring Points and Instruments Item Measuring Point Measuring Instrument Remarks (Reference Measured Value) * Power supply voltage V 1 Across R-S, S-T and T-R <Across L 1 -L 2 , L 2 -L 3 and L 3 -L 1 > Moving-iron type AC voltmeter Commercial power supply Within permissible AC voltage fluctuation ( Refer to Page [...]
-
Page 52
6 CHAPTER 6 SPECIFICATIONS This chapter provides the "specifications" of this product. Alway s read the instructions before using the equipment. 6.1 Standard Specifications ・・・・・・・・・・・・・・・・・・・・・ 41 CHAPTER 1 OUTLINE CHAPTER 2 INSTALLATION AND WIRING CHAPTER 3 OPERATION CHAPTER 4 PARAMETERS CHAPTER[...]
-
Page 53
6.1 Standard specification SPECIFICATIONS 41 6.1.1 Model specifica tions Model FR-A560L- □□□ K-NA 375 450 530 600 670 750 800 900K Constant torque 375 450 530 600 670 750 800 900 Applicable motor capacity (kW) (Note 1) Variable torque 450 530 600 670 750 800 900 950 Constant torque 550 650 750 800 900 1000 1100 1200 Rated capacity (HP) (Note [...]
-
Page 54
SPECIFICATIONS 42 6.1.2 Common specifications Control system Soft-PWM control/high carrier frequency PWM control (V/F control or advanced magnetic flux vector control can be selected) Output frequency range 0.2 to 400Hz Analog input 0.015Hz/60Hz (terminal 2 input: 12 bits/0 to 10V, 11 bits/0 to 5V, terminal 1 input: 12 bits/ − 10 to +10V, 11 bits[...]
-
Page 55
SPECIFICATIONS 43 Operating status Selection can be made from output frequency, motor current (steady or peak value), output voltage, frequency setting, running speed, motor torque, converter output voltage (steady or peak value), electronic overcurrent protection load factor, input power, output power, load meter, motor exciting current, cumulativ[...]
-
Page 56
SPECIFICATIONS 44 6.1.3 Outline drawings l FR-A560L-450K, 375K l Accessory DC REACTOR (for FR-A560L-450K, 375K) X U 4.5 45 450 ± 10 410 ± 5 330 over 240 over 215 150 2-M12 bolt 2-terminal (4- φ 15hole) X U X U Earth terminal (M6 screw) 4-hole (M10 screw) Control Panel This (Top attachment) should be removed at operating because of air exhaust. T[...]
-
Page 57
SPECIFICATION S 45 z FR-A 560L-530K ∼ ∼ ∼ ∼ 900K DC reactor is internally mounted and wired.[...]
-
Page 58
SPECIFICATION S 46[...]
-
Page 59
7 APPENDICES This chapter provides the "appendices" for use of this product. Alway s read the instructions before using the equipment. Appendix 1 Data Code List ・・・・・・・・・・・・・ Refer to FR-A540L/ A560L Appendix 2 List of Parameters Classified by Purpose of Use ・・・・・・・・・・・ Refer to FR-A540L/ A5[...]
-
Page 60
A ppendix 3 APPENDICES 47 A ppendix 3 Installation procedure for cooling fan ( FR-A 560L-530K ∼ ∼ ∼ ∼ 900K) 1. Install and fix bolts and screws. Step1 Put cooling f ans and f an covers . Step2 Fix cooling fans and fan cover s by M12 bolts. Step3 Put cooling f an ceilings and fix by M4 screws. Te r m in a l M12 bolt Screw Fa n cov er Coo lin[...]
-
Page 61
INSTA LLA TION AND W IRI N G 48 2. Wiring betw een cooling fan and terminals is as follow s; 2 1 E K G R W 4 EF-40E T B CONVERTER 3 2 1 E K G R W 4 EF-30E T B CONTROL 3 2 1 E K G R W 4 EF-40ETB INVERTER 3 K : Black W : Wh i t e R : Red G : G reen Step 4 Connect cooling f an wires as above drawing. 3. Check the air flow direction OK OK OK[...]
-
Page 62
A ppendix 4 APPENDICES 49 A ppendi x 4 Installation procedure for brake unit ( option) (FR-A 560L-530K ∼ ∼ ∼ ∼ 900K) Step1 Connect wires as the next drawing. W iring between FR-A500L and MT-BR5 (option) Step2 Set param eter 30 : when brak e unit is us ed, set to 1. Step3 Set param eter 70 : when brak e unit is us ed, set to 10%. This brake [...]
-
Page 63
A ppendix 5 APPENDICES 50 A ppendi x 5 Shipment case example[...]
-
Page 64
MITSUBISHI ELECTRIC CORPORATION IB-T7260-06 (200203) Printed in Japan Specifications subject to change without notice. ST036F(200203) 長 MEE HEAD OFFICE : MITSUBISHI DENKI BLDG MARUNOUCHI TOKYO 100-8310[...]