Go to page of
Similar user manuals
-
Air Conditioner
Mitsubishi Electronics TC-24A
56 pages 3.81 mb -
Air Conditioner
Mitsubishi Electronics SLZ-KA12NA
8 pages 0.89 mb -
Air Conditioner
Mitsubishi Electronics PEAD-A30AA
42 pages 5.96 mb -
Air Conditioner
Mitsubishi Electronics PEH 10
8 pages 0.5 mb -
Air Conditioner
Mitsubishi Electronics PE-7MYC
116 pages 2.01 mb -
Air Conditioner
Mitsubishi Electronics PEH-4EK
8 pages 0.5 mb -
Air Conditioner
Mitsubishi Electronics MSZ-GA22VA
15 pages 1.38 mb -
Air Conditioner
Mitsubishi Electronics PCH42GK
70 pages 1.52 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Mitsubishi Electronics MSY-D30/36NA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsubishi Electronics MSY-D30/36NA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Mitsubishi Electronics MSY-D30/36NA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Mitsubishi Electronics MSY-D30/36NA should contain:
- informations concerning technical data of Mitsubishi Electronics MSY-D30/36NA
- name of the manufacturer and a year of construction of the Mitsubishi Electronics MSY-D30/36NA item
- rules of operation, control and maintenance of the Mitsubishi Electronics MSY-D30/36NA item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsubishi Electronics MSY-D30/36NA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsubishi Electronics MSY-D30/36NA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsubishi Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsubishi Electronics MSY-D30/36NA.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsubishi Electronics MSY-D30/36NA item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
JG79A061H01 SPLIT -TYPE AIR CONDITIONERS INSTALLATION MANUAL ENGLISH Required Tools for Installation Phillips screwdriver Level Scale Utility knife or scissors 3 in. (75 mm) hole saw T orque wrench Wrench (or spanner) 5/32 in. (4 mm) hexagonal wrench Flare tool for R410A Gauge manifold for R410A V acuum pump for R410A Charge hose for R410A Pipe cut[...]
-
Page 2
1-3. SPECIFICA TIONS 1-3-1. POWER SUPPL Y AND INDOOR/OUTDOOR WIRE CONNECTION • Power should be taken from an exclusive branched circuit. • Wiring work should be based on applicable technical standards. • Wiring connections should be made following the diagram. • Securely tighten screws. Connecting wires and the ground wire • Use solid con[...]
-
Page 3
Outdoor unit installation 2-13/16 in. (70 mm) or more/ 5-1/8 in. (130 mm) or more for left and left back piping (using spacer) 1-4. INST ALLA TION DIAGRAM ACCESSORIES Check the following parts before installation. <Indoor unit> (1) Installation plate 1 (2) Attachment screws for the installa- tion plate 4 × 25 mm 7 (3) Remote controller holde[...]
-
Page 4
Installation plate (1) Center of ø 3 in. (75 mm) hole 8-11/16 in. (220 mm) or more 4-11/16 in. (120 mm) or more 2-13/16 in. (70 mm) or more 5-1/8 in. (130 mm) or more for left and left back piping (using spacer) Ceiling Wall Wall Attachment screw (2) * Same for left hole. Insert the scale. * Align the scale with the line. * Level • Make ground w[...]
-
Page 5
Liquid pipe Gas pipe Felt tape (7) Indoor/outdoor unit connecting wire (A) Piping tape (G) 2-5. PIPE FORMING AND DRAIN PIPING 2-5-1. PIPE FORMING • Place the drain hose below the refrigerant piping. • Make sure that the drain hose is not crowded or bent. • Do not pull the hose when applying the tape. :KHQ WKHGUDLQ KRVH SDVV[...]
-
Page 6
3-1. CONNECTING WIRES FOR OUTDOOR UNIT 1) Remove the service panel. 2) Remove the conduit cover. 3) Attach the conduit connector to conduit cover with lock nut then secure it against unit with screws. 4) Connect ground wires of indoor/outdoor unit connecting wire (A) and power supply cord (K) to the TB support. 5) Loosen the terminal screw, and att[...]
-
Page 7
3-2. FLARE CONNECTION 1) Cut the copper pipe as straight as possible with a pipe cutter. (Fig. 1, 2) 2) Remove all burrs from the cut section of the pipe, ensuring that precautions are taken to avoid getting metal shavings into the piping. (Fig. 3) 5HPRYHÀDUHQXWVDWWDFKHGWRLQGRRUDQGRXWGRRUXQLWVWKHQSXWWK[...]
-
Page 8
4-4. EXPLANA TION TO THE USER • Using the OPERATING INSTRUCTIONS, explain to the user how to use the DLUFRQGLWLRQHU WKHUHPRWHFRQWUROOHU UHPRYLQJWKHDLU ¿OWHUVSODFLQJRU UHPRY - ing the remote controller from the remote controller holder, cleaning methods, precautions for operation, etc.) • Recommend that[...]