Go to page of
Similar user manuals
-
Air Conditioner
Mitsubishi Electronics PMFY-P08NBMU-E
36 pages 2.24 mb -
Air Conditioner
Mitsubishi Electronics PUH-2.5AKA PUH-3VKA*
16 pages 0.71 mb -
Air Conditioner
Mitsubishi Electronics JY992D93901E
8 pages 0.22 mb -
Air Conditioner
Mitsubishi Electronics PUZ-A36NHA2-BS
12 pages 1.84 mb -
Air Conditioner
Mitsubishi Electronics PEH-7MYA
115 pages 2.7 mb -
Air Conditioner
Mitsubishi Electronics MSZ-GE42VA
2 pages 0.67 mb -
Air Conditioner
Mitsubishi Electronics PLFY-P-VLMD-E
15 pages 0.74 mb -
Air Conditioner
Mitsubishi Electronics PL30FK21
67 pages 1.73 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Mitsubishi Electronics MXZ-3B24NA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsubishi Electronics MXZ-3B24NA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Mitsubishi Electronics MXZ-3B24NA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Mitsubishi Electronics MXZ-3B24NA should contain:
- informations concerning technical data of Mitsubishi Electronics MXZ-3B24NA
- name of the manufacturer and a year of construction of the Mitsubishi Electronics MXZ-3B24NA item
- rules of operation, control and maintenance of the Mitsubishi Electronics MXZ-3B24NA item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsubishi Electronics MXZ-3B24NA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsubishi Electronics MXZ-3B24NA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsubishi Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsubishi Electronics MXZ-3B24NA.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsubishi Electronics MXZ-3B24NA item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Split-type Air-Conditioner MXZ-3B24NA MXZ-3B30NA MXZ-4B36NA Español Français English Installation Manual For INST ALLER • This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of indoor unit. Any structural alterations necessary for installation must comply with local buil[...]
-
Page 2
En-1 n Do not install the unit by yourself (user). Incompleteinstallationcould causereorelectric shock,injuryduetothe unit falling,or leakageof water.Consultthe dealerfrom whomyou purchasedthe unitoraqualiedinstaller. n Perform the installation secur[...]
-
Page 3
En-2 1-4.SELECTINGTHEINST ALLA TIONLOCA TION • Where it is not exposed to strong wind. • Whereairowisgoodanddustless. • Whererainordirectsunshinecanbeavoidedasmuchaspossible. • Where neighbours are not annoyed by operation sound or hot air. • Whererigidwallor[...]
-
Page 4
En-3 1-5.INST ALLA TIONDIAGRAM Units should be installed by licensed contractor according to local code requirements. After the leak test, apply insulat - ing material tightly so that there is no gap. W h e n t h e p i p i n g i s t o b e a t - tached to a wall containing metals (tin plated) or metal netting, use[...]
-
Page 5
En-4 2. OUTDOORUNITINST ALLA TION 2-1.INST ALLINGTHEUNIT Fix here with M10 bolts. Makethesetting depth deeper. Makewithwider. Anchor leg 25(31/32)orless Anchor both length Anchor both pitch (Unit:mm(inch)) • Besuretoxtheunit’slegswithboltswheninstallingit. ?[...]
-
Page 6
En-5 3-2.PIPECONNECTION 1) Applya thin coatof refrigeration oil(G) to theared ends ofthe pipes and the pipe connections of the outdoor unit. 2) Alignthecenter ofthepipewith thatofthe pipeconnectionsof theoutdoor unit,thenhandtighten?[...]
-
Page 7
En-6 4-3.TESTRUN • Test runs of the indoor units should be performed individually. See the installation manual comingwiththeindoorunit,andmakesurealltheunitsoperateproperly. • If the test run with all the units is performed at once, possible erroneous connect[...]
-
Page 8
En-7 5. RELOCA TION ANDMAINTENANCE 5-1.PUMPINGDOWN When relocating or disposing of the air conditioner , pump down the system following the procedure below so that refrigerant is not released into the atmosphere. 1) Connectthegaugemanifoldvalvetotheserviceportofthestopvalveonthegaspi[...]