A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Mitsubishi Electronics SEZ-A24AR, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsubishi Electronics SEZ-A24AR one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Mitsubishi Electronics SEZ-A24AR. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Mitsubishi Electronics SEZ-A24AR should contain:
- informations concerning technical data of Mitsubishi Electronics SEZ-A24AR
- name of the manufacturer and a year of construction of the Mitsubishi Electronics SEZ-A24AR item
- rules of operation, control and maintenance of the Mitsubishi Electronics SEZ-A24AR item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsubishi Electronics SEZ-A24AR alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsubishi Electronics SEZ-A24AR, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsubishi Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsubishi Electronics SEZ-A24AR.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsubishi Electronics SEZ-A24AR item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Air -Conditioner s SEZ-A12, A18, A24AR English INST ALLA TION MAN U AL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. FOR INSTALLER[...]
-
Page 2
2 Contents 1. Safety precautions ................................................................................... 2 2. Selecting the installation location ............................................................. 2 3. Installation diagram & Accessories .......................................................... 3 4. Indoor unit installati[...]
-
Page 3
3 3. Installation diagram & Accessories 3.1. Indoor unit (Fig. 3-1) 1 Air inlet (rear side) *Select the either back side or bottom side 2 Electrical par ts bo x 3 Suspension bolt pitch 5 Access door 6 Service space (It is necessar y to maintain a working service area from the ceiling.) 7 Air inlet (bottom side) *Select the either back side or b[...]
-
Page 4
4 AB 1 2 3 3. Installation diagram & Accessories Fig. 3-3 3.3. Checking the indoor unit accessories (Fig. 3-3) Check that the indoor unit is equipped with the f ollo wing parts and accessor ies: A Refrigerant pipe parts 1 Pipe cov er (for refrigerant piping joint) Small diameter × 1 Large diameter × 1 2 Bands for tempor ary tightening of pipe[...]
-
Page 5
5 5. Refrig erant piping w ork 5.1. Refrigerant pipe (Fig. 5-1) Maximum difference betw een heights of indoor unit and outdoor unit, the length of refrigerant piping and the number of bends in piping are within limits shown belo w . Models (A) Pipe length (B) Height (C) Number of (one wa y) difference bends (one way) SEZ-A12AR max. 20 m max. 12 m m[...]
-
Page 6
6 a d c b ef 90 ° d c b a 5. Refrigerant piping work b a a b e b c d c A 5.2. Flaring work • Main cause of gas leakage is def ect in flaring work. Carry out correct flar ing w ork in the following procedure . 5.2.1. Pipe cutting (Fig. 5-3) • Using a pipe cutter cut the copper tube correctly . 5.2.2. Burrs remo v al (Fig. 5-4) • Completely re[...]
-
Page 7
7 5. Refrig erant piping w ork 5.4. Purging pr ocedures leak test PURGING PROCEDURES Connect the refrigerant pipes (both the liquid and gas pipes) between the indoor and the outdoor units. Remove the service port cap of the stop valv e on the side of the outdoor unit gas pipe . (The stop valv e will not work in its initial state fresh out of the f [...]
-
Page 8
8 7. Electrical work N A B H C F D E A G N 2 3 N 2 3 N L L 1 2 N B C F E N 2 3 12 N L L A H A D C E A G N 3 N F N L L (1) SEZ-A12AR (1:1 SYSTEM) 7.1. P ower supply (Fig. 7-1) Electrical specification Input capacity Main Switch/Fuse (A) P ow er supply SEZ-A12AR SEZ-A18AR SEZ-A24AR (1 phase ~/N, 220-240V , 50Hz) 10 20 20 Warning: • Do not use inter[...]
-
Page 9
9 7. Electrical work Fig. 7-4 LN N 2 3 N 2 3 1 2 5 12 7 6 3 4 65 mm 15 mm 1 2 Fig. 7-3 • P erform wiring as shown in the diagr am to the lower left. (Procure the cable lo- cally). (Fig. 7-3) Make sure to use cables of the correct polarity only . 1 Connecting cable 2 P ow er supply cable 4 core VVF cab le 3 core with ground IEC cord • SEZ-A12:1.[...]
-
Page 10
10 7.4. Outdoor unit (Fig. 7-8) • Connect cable from the indoor unit correctly on the terminal-bloc k. • Use the same terminal block and polarity as is used with the indoor unit. • For aftercare maintenance , giv e extr a length to connecting cable . • Both end of connecting cable (e xtension wire) are peeled off . When too long, or connect[...]
-
Page 11
11 9. Air filter installation 9.1. Confirmation of enc losed par ts (Fig. 9-1) • Please ensure all the par ts sho wn below are present bef ore starting installation. 1 Filter × 1 2 Filter rail × 1 3 Filter rail × 1 4 ST . screw (4 × 10) × 14 5 Clamp × 2 6 Seal × 2 12 3 Fig. 9-1 6 Cut out Cut out Hole 45 A A B C C 2 1 3 4 Fig. 9-2 9.2. Filt[...]
-
Page 12
12 9. Air filter installation 9.4. Filter installation points (Rear air intake) (Fig. 9-4) 1. Inser t the filter into rail 2 2. Hook the filter onto rail 3 A Control box B Drain pan D Filter E Rail 2 F Rail 3 Fig. 9-4 1 2 B A E D F Fig. 9-5 2 1 A E D F A F H G E 9.5. Filter installation points (Bottom air intake) (Fig. 9-5) 1. Inser t the filter in[...]
-
Page 13
13 10.1. Bef ore test run s After completing installation and the wiring and piping of the indoor and outdoor units, c heck f or refrigerant leakage, looseness in the power suppl y or control wiring, wr ong polarity , and no disconnection of one phase in the supply . s Use a 500-volt megohmmeter to c heck that the resistance between the po wer supp[...]
-
Page 14
14 10.4. A UT O REST ART FUNCTION This model is equipped with the A UT O REST ART FUNCTION. When the indoor unit is controlled with the remote controller , the operation mode, set temperature , and the fan speed are memorized b y the indoor controller board. The auto restart function sets to wor k the moment the po wer has restored after power f ai[...]
-
Page 15
15 1 Wiring from the Remote Control This wire is connected to terminal block f or remote controller of the indoor unit (non- polar). 2 When a Different Refrigerant System Grouping is Used. Up to 4 refrigerant systems can be controlled as one group using the MA remote controller . There is need to set up JP17, JP18 jumper wire of indoor controller b[...]
-
Page 16
Please be sure to put the contact address/telephone number on this manual before handing it to the customer. • Low Voltage Directive 73/23/ EEC • Electromagnetic Compatibility Directive 89/ 336/ EEC This product is designed and intended for use in the residential, commercial and light-industrial environment. HEAD OFFICE: MITSUBISHI DENKI BLDG.,[...]