Mitsumi electronic 10 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Mitsumi electronic 10, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsumi electronic 10 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Mitsumi electronic 10. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Mitsumi electronic 10 should contain:
- informations concerning technical data of Mitsumi electronic 10
- name of the manufacturer and a year of construction of the Mitsumi electronic 10 item
- rules of operation, control and maintenance of the Mitsumi electronic 10 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsumi electronic 10 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsumi electronic 10, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsumi electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsumi electronic 10.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsumi electronic 10 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MAC Ope ra tor Termina l Human-Machine-Interfac e In stal la tion Manua l MAC 1 0 MAC 1 2 MITSU BIS HI ELECTRI C MITSU BIS HI ELECTRIC EU RO PE B.V . FACTORY AU TO MA TI O N[...]

  • Page 2

    1 GB Contents Safety precautions ........................................... 2 Introduction ..................................................... 4 Function overvie w ........................................... 5 Installation ....................................................... 6 A small example ............ ................... ............. 10 [...]

  • Page 3

    2 GB Safety pr ecautions General – Check the delivery for tran sport damage. If damage is found, advise your supplier. – The product fulfils the requirements of article 4 of EMC directive 89/336/EEC. – Do not use the pro duct in an explosive env i- ronment. – Modifications, chang es and addition s to the product are forbidden. – U se o nl[...]

  • Page 4

    3 GB Service and maintenance – The agreed warrenty applies. – Clean the display and face with a soft cloth and mild detergent. – Repairs should be made by qualified person- nel. At disassembly and scrapping – Local regulations apply concerning recy c- ling of products or part. – Please note that the lithium battery , electro- lyte condens[...]

  • Page 5

    4 GB Intr oduction This leaflet describes the operator´s panels MA C 10/MT A-10 and MA C 12/MT A-12. Hereafter these products are referred to as the terminal. In the manual we refer to the software package MA C Programmer/SW -MT A for DOS and MA C Programmer+/SW -MT A-WIN for W indows. Hereafter these products are referred to as the PC software. T[...]

  • Page 6

    5 GB Summary of functions T extblock T extblock is used to build up dialogs. A T ext- block can consist of an arbitrary number of text lines of up to 16 characters long. Static text Static text is text written in textblock which is not changed when executing the program. Dynamic objects Dynamic objects are fields in th e text which are linked to th[...]

  • Page 7

    6 GB Installation The terminals are connected to FX0, FX0N or FX PLC system. Connection to a FX0/FX0N PLC system Connect the MA C 10/12-CAB (8-p in MINI- DIN) cable to the outlet in the bo ttom of the ter- minal. The cable is straight; the contact at each end is compatible with both the terminal and the PLC system. The cable has a maximum length of[...]

  • Page 8

    7 GB Connection to a FX PLC system The terminal is connected to a FX PLC system using the FX-20P-CABN cable. The cable has a macimum length of 3 meter and the commu ni- cation speed i 9600 baud. The terminal is powered by the PLC system via the cable. If a longer cable is required, the ter- minal must be powered from a source other than the PLC sy [...]

  • Page 9

    8 GB K eyboard The terminal keyboard incorporates 6 mem- brane keys which are used to performe the follo- wing functions: Set manoeuvrable digital ob ject (ON). Increase value of manoeuvrable analog object. Execute jump. Select/ex ecute choice from a multiple choice object. Reset manoeuvrable digital object (OFF). Decreace value of manoeuvrable ana[...]

  • Page 10

    9 GB Settings All settings for the terminal must be done in the PC software. It is assumed that the PC software for W indows is installed on your PC and that you have started up with a new project. See the PC software maunal for further details. A number of basic settings have to be entered before using the terminal. The settings are entered in the[...]

  • Page 11

    10 GB A small example The following section giv es a small example of how to start creating applications quickly . The example follows the whole sequence from buil- ding up an application to executing to the PLC system. The terminal must be connected to a personal computer with the PC software. In this example we shall make a textblock which sho ws[...]

  • Page 12

    11 GB the signal is 1, in this example ON. 10. Press OK to close the dialog box. The dy na- mic object is now shown by # and two - on the screen. When the program is ready you can connect the terminal to the PLC sy stem. Mac10eng Seit e 11 Freitag, 5. Februar 1999 3:29 15[...]

  • Page 13

    12 GB Over view Mode selection Keep the ke ys shown to the left pressed during terminal power -up to enter the mode Communi- cation with MP . The terminal norm ally enters Run mode during power- up. For a complete list of other modes possible see User´s manual for the terminal. Dynamic objects The following dynamic text objects can be used in bloc[...]

  • Page 14

    13 GB System block Certain blocks are reserved for special purpo- ses: 0 Main menu 990 Reserved for compatibility with other terminals 991 T ime channels 992-999 Reserved for compatibility with other terminals Mac10eng Seit e 13 Freitag, 5. Februar 1999 3:29 15[...]

  • Page 15

    14 GB T e chnical data Front panel W idth 96 x height 72 x depth 3 mm. Mounting depth MA C 10/MT A-10: Max 37 mm. MA C 12/MT A-12: Max 41 mm. Mounting holes 92 ±1 mm x 68 ±1 mm. Front panel seal IP 65 Rear panel seal IP 20 Front panel material 1,5 mm anodized aluminium and membrane keyboard. Overlay f ilm of polyester with back- side printing. Co[...]

  • Page 16

    15 GB Real time clock Minimum 10 years lifetime. Supply voltage +5 VDC from P LC system CPU port via com- munication cable. Internal logic voltage +5 VDC ±5%. Po wer consumption MA C 10/MT A-10: 70 mA. MA C 12/MT A-12: 150 mA. Ambient temperature 0º to +50ºC Storage temperature -20º to +60ºC Air humidity Max 90% without condensation. Interfer [...]

  • Page 17

    16 GB Mac10eng Seit e 16 Freitag, 5. Februar 1999 3:29 15[...]

  • Page 18

    A-1 Cadbild.fm Seit e 1 Freitag, 5. Febru ar 1999 4:45 16[...]

  • Page 19

    A-2 Cadbild.fm Seit e 2 Freitag, 5. Febru ar 1999 4:45 16[...]

  • Page 20

    A-3 Cadbild.fm Seit e 3 Freitag, 5. Febru ar 1999 4:45 16[...]

  • Page 21

    A-4 Cadbild.fm Seit e 4 Freitag, 5. Febru ar 1999 4:45 16[...]

  • Page 22

    A-5 Cadbild.fm Seit e 5 Freitag, 5. Febru ar 1999 4:45 16[...]

  • Page 23

    A-6 Cadbild.fm Seit e 6 Freitag, 5. Febru ar 1999 4:45 16[...]

  • Page 24

    A-7 Cadbild.fm Seit e 7 Freitag, 5. Febru ar 1999 4:45 16[...]

  • Page 25

    A-8 Cadbild.fm Seit e 8 Freitag, 5. Febru ar 1999 4:45 16[...]

  • Page 26

    MITSU BIS HI ELECTRI C MITSU BIS HI ELECTRIC EU RO PE B.V . FACTORY AU TO MA TIO N GOT HA ER STR. 8, D- 40880 RA TIN GE N TEL.: (0 21 02) 4 86- 1 0 , FAX: (0 21 02) 4 86-1 1 2[...]