Mitsumi electronic E Series manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Mitsumi electronic E Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsumi electronic E Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Mitsumi electronic E Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Mitsumi electronic E Series should contain:
- informations concerning technical data of Mitsumi electronic E Series
- name of the manufacturer and a year of construction of the Mitsumi electronic E Series item
- rules of operation, control and maintenance of the Mitsumi electronic E Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsumi electronic E Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsumi electronic E Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsumi electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsumi electronic E Series.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsumi electronic E Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Mac E Series Human Machine Interf ace Installation M anu al E1070 INDUSTRIAL AUTOMATION MIT SU BI S HI ELE C TRI C MI T SU BI S HI ELE C TRI C Art. no.: 169276 10 02 2006 Version A[...]

  • Page 2

    [...]

  • Page 3

    Foreword Mitsubishi Electric, MA00776 Installation manual for the E1000 series oper ator terminals F oreword The E1000 operator terminal is develo ped to satisfy the demands of human- machine communication. Built-in functi ons such as displaying and controlling text, dynamic indication, time channels, alarm and recipe handling are included. The ope[...]

  • Page 4

    Foreword Mitsubishi Electric, MA00776[...]

  • Page 5

    Table of Contents Mitsubishi Electric, MA00776 T able of Contents 1 Safety Precautions............................................................................. 1-1 1.1 UL Installation .................... ........................................................... 1-1 1.2 General .................................................................[...]

  • Page 6

    Table of Contents Mitsubishi Electric, MA00776[...]

  • Page 7

    Safety P r ecautions Mitsubishi Electric, MA00776 1-1 1 Safety Precautions Both the installer and the owner and/or oper ator of the operator terminal must r ead and understand this installation manual. 1.1 UL Installation P ower , in p ut a nd o ut pu t ( I/ O) wi ri ng mu st be in ac co rd an ce w i th Cl as s 1 , Di vi si on 2 wiring methods (Art[...]

  • Page 8

    Safety P r ecautions 1-2 Mitsubishi Electric, MA00776 1.4 Serv ice and Maintenance – Only qualified personnel should carry out repairs. – The agreed warranty applies. – Before carrying out any cleaning or maintenance operations, disconnect the equipment from the electrical supply . – Clean the display and surrounding front co ver with a sof[...]

  • Page 9

    In s ta l l a t i o n Mitsubishi Electric, MA00776 2-1 2 Installation 2.1 Space Requirements – Installation plate thickness: 1.5 - 9.0 mm (0.06 - 0.35 inch) – S pace requirements when installing the operator terminal: Caution The openings on the enclosure are for air convection. Do not cover these openings. 2.2 Installation Process 1. U npack a[...]

  • Page 10

    In s ta l l a t i o n 2-2 Mitsubishi Electric, MA00776 3. Secure the operator terminal in position, using all the fastening holes and the pro vided brackets and screws: 4. Connect the cables in the specified order . U se an M5 screw and a grounding conductor (as short as possible) with a cross-section of minimum 2.5 mm 2 . 5. Carefully remo ve the [...]

  • Page 11

    In s ta l l a t i o n Mitsubishi Electric, MA00776 2-3 2.2.1 Mode Switches All mode switches must be in OFF position during operator terminal use. The mode switches should not be touched unless by qualified personell. 2.2.2 Connections to the Controller F or information about the cables to be used when connecting the operator terminal to the contro[...]

  • Page 12

    In s ta l l a t i o n 2-4 Mitsubishi Electric, MA00776[...]

  • Page 13

    T e chnical Data Mitsubishi Electric, MA00776 3-1 3 T echnical Data Pa ra m e t e r E1070 Front panel, W x H x D 285 x 177 x 6 mm Mounting depth 56 mm (156 mm including clearance) Front panel seal IP 66 R ear panel seal IP 20 K eyboard material Membrane switch keyb oard with metal domes. Overlay film of Autotex F157 * with print on reverse side. 1 [...]

  • Page 14

    T echnical Data 3-2 Mitsubishi Electric, MA00776[...]

  • Page 15

    Chemical Resistance Mitsubishi Electric, MA00776 4-1 4 Chemical Resistance 4.1 Metal Casing The frame and casing material is powd er-coated aluminum. This po wder paint withstands exposure of up to 24 hours du ration to the follo wing chemicals without visible change: 4.2 Keyboard and Display 4.2.1 Autotex F157 Autotex F157 co vers the membrane key[...]

  • Page 16

    Chemical Resistance 4-2 Mitsubishi Electric, MA00776 Autotex withstands DIN 42 115 P art 2 exposure of up to 1 hour duration to glacial acetic acid without visible change. Autotex is not r esistant to high pressur e steam at over 100 ° C or the follo wing chemicals: Autotex withstands 24 hours exposur e to the following r eagents at 50 ° C withou[...]

  • Page 17

    Chemical Resistance Mitsubishi Electric, MA00776 4-3 Carbon tetrachloride Hydrogen pe roxide <28% Sodium hypochlorite <10% Caustic soda <48% Isopropyl alcohol Sulfuric acid (specific gravity 1.84) Citric acid K erosene Sulfuric acid <30% Cotton seed oil Methy alcohol T oluene[...]

  • Page 18

    Chemical Resistance 4-4 Mitsubishi Electric, MA00776[...]

  • Page 19

    Oper ator T erminal Drawings Mitsubishi Electric, MA00776 5-1 5 Oper ator T erminal Dr awings 5.1 Communication P orts Dr awing N o . 5005S, Date 2004-10-27 RS-232 RS-422 RS-422/485 RS-485 Ethernet USB[...]

  • Page 20

    Oper ator T erminal Drawings 5-2 Mitsubishi Electric, MA00776 5.2 E1070 Outline Dr awing N o . 5031S, Date 2004-10-14[...]

  • Page 21

    Oper ator T erminal Drawings Mitsubishi Electric, MA00776 5-3 5.3 E1070 T ext Strip Dr awing N o . 5027S, Date 2004-08-12[...]

  • Page 22

    Oper ator T erminal Drawings 5-4 Mitsubishi Electric, MA00776[...]

  • Page 23

    [...]

  • Page 24

    HEADQUARTERS MITSUBISHI ELECTRIC EUROPE EUROPE B.V. German Branch Gothaer Straße 8 D-40880 Ratingen Phone: +49 (0) 2102 / 486-0 Fa x : +49 (0) 2102 / 486-1120 e mail: megfamail@meg.mee.com MITSUBISHI ELECTRIC FRANCE EUROPE B.V. French Branch 25, Boulevard des Bouvets F-92741 Nanterre Cedex P h o n e :+ 3 315 56 85 56 8 F a x : + 3 315 56 85 68 5 e[...]