Go to page of
Similar user manuals
-
Computer Hardware
Mitsumi electronic 10
26 pages 1.26 mb -
Air Conditioner
Mitsumi electronic PLA-ABA
52 pages 4.11 mb -
Home Theater Server
Mitsumi electronic QS0J71GF11-T2
24 pages 1.06 mb -
Air Conditioner
Mitsumi electronic MSZ-ANA
40 pages 0.28 mb -
Air Conditioner
Mitsumi electronic MUZ-GANA
40 pages 0.28 mb -
CRT Television
Mitsumi electronic 738 Series
108 pages 18.84 mb -
Air Conditioner
Mitsumi electronic PUZ-A18/24/30/36/42NHA3
52 pages 4.11 mb -
Flat Panel Television
Mitsumi electronic WD-57734
84 pages 3.56 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Mitsumi electronic FR-PU07/FR-PU07BB, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsumi electronic FR-PU07/FR-PU07BB one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Mitsumi electronic FR-PU07/FR-PU07BB. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Mitsumi electronic FR-PU07/FR-PU07BB should contain:
- informations concerning technical data of Mitsumi electronic FR-PU07/FR-PU07BB
- name of the manufacturer and a year of construction of the Mitsumi electronic FR-PU07/FR-PU07BB item
- rules of operation, control and maintenance of the Mitsumi electronic FR-PU07/FR-PU07BB item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsumi electronic FR-PU07/FR-PU07BB alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsumi electronic FR-PU07/FR-PU07BB, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsumi electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsumi electronic FR-PU07/FR-PU07BB.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsumi electronic FR-PU07/FR-PU07BB item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
FR-PU07/FR-PU07BB INSTRUCTION MANUAL D INVERT ER INVER TER Option unit INSTRUCTION MANUAL INVER TER HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAP AN 1 2 3 4 6 5 FR-PU07 FR-PU07BB Parameter unit IB(NA)- 0600240ENG-D(0901) ME E Printed in Japan Specifications subject to change without notice . PRE -OPERA TION INSTRUC [...]
-
Page 2
A-1 Than k you fo r choo sing th e Mitsu bishi inve rter option unit. This i nstruc tion ma nual giv es handl ing i nformat ion and precau tion s for us e of th is equ ipmen t. Inco rrect h andl ing m ight cause an u nexp ected faul t. Be fore using the equi pmen t, pl ease read t his man ual care fully to use the eq uipme nt to its op timum. Pleas[...]
-
Page 3
A-2 2. Additional I nstructions T o pr event in jury , damage or produ ct fa ilure, pl ease not e the followin g points. (1) T ransportation and mounting (2) T est operation and adjustment (3) Usage (4) Correc tive actions fo r alarm CAUTION • Do not in sta ll and op erat e the p arameter unit (FR -PU07 /FR- PU07BB) i f it is damaged or has part [...]
-
Page 4
A-3 (5) Dispo sal (6) Gene ral ins truct ion 3. Safety Precautions for Alkaline Battery When us ing an alkali ne batt ery , read the in stru ction manual s carefu lly befo re usin g them . 4. Safety Precautions for Nickel Metal Hydride Battery When using a ni ckel m etal hydride b attery a nd char ger, read the instru ction m anua ls caref ully b e[...]
-
Page 5
I — CONTENTS — INTRODUCTION 1 1 PRE-OPERA TION INSTRUCTIONS 2 1.1 Supporting inverter mod els .................................................................................................. ............ 2 1.2 Unpacking and Product Conf irmation .......................................................................................... ...4 1.[...]
-
Page 6
II 1.5.2 PU buzzer control (Pr. 990) ............ ......... ....... ......... ....... .......... ......... ....... ......... ....... ......... .... ......... ....... ....... 20 1.5.3 PU contrast adjustment (Pr. 991) ......... .......... ...... .......... ...... .......... .......... ...... .......... ...... ....... ...... .......... ...... . 21 2 F[...]
-
Page 7
III 2.5 Calibration of the Meter (Frequen cy Meter).................................................................................. .42 2.5.1 Calibratio n of the F M terminal ........... ......... ....... .......... ......... ....... ......... ....... .......... ...... ....... ...... .......... ...... .... 42 2.5.2 Calibration of the AM termi nal[...]
-
Page 8
IV 3.3.1 Precautions f or parameter un it operatio n .. .......... ....... ......... ....... ......... .......... ....... ......... ....... ...... ....... ......... . 81 4O P E R A T I O N 82 4.1 How to Select the Operation Mode ............................................................................................ .....82 4.1.1 Switching fr o[...]
-
Page 9
V 6.2.1 FR-PU07 outline dime nsion drawings ........ ....... .......... ......... ....... ......... ....... .......... ......... ....... ..... . .......... ...... . 93 6.2.2 FR-PU07BB outline dimens ion drawings ............. ....... ......... ....... ......... .......... ....... ......... ....... ........ ........... .... 94 APPENDIX 95 Appendix 1[...]
-
Page 10
1 INTRO DUCTION This product is a unit for setting inverter functions (parameters) and has the following features. · An op eration pa nel ca n be remo ved and a param eter unit c an be con nected. · Setti ng such as direc t inpu t method with a numeric keyp ad, operat ion s tatus ind ication, and help funct ion are usab le. · Eigh t language s c[...]
-
Page 11
2 1 PRE-OPERATION INSTRUCTIO NS 1.1 Suppor ting inve rter models • FR-PU07/FR-PU07BB supporting models *1 If a product assembled before the above date is connected when the inverter power is O FF , "MITS UBISHI" appears on the liquid crystal display screen and it is inoperative. If a product assembled before the above date is connected [...]
-
Page 12
3 1 Unpacking and Product Confir mation z SERIAL number For p rod uct as semb led dat e, c heck the SER IAL nu mbe r in dic ated o n th e inv ert er r ati ng pla te o r pack age. z SERIAL number chec k Refer to the invert er manual for the locat ion of t he rating p late. Rating plat e example { { {{{{{{ S ERIAL (Serial No.) Symbol Y ear Month [...]
-
Page 13
4 Unpacking and Product Confirma tion 1.2 Unpacki ng and Produ ct Confir mation T ake the parameter unit out of the pac kage, check the unit name, and confirm that the product is as you ordered and intact. 1.2.1 Unpacking confirmation Check the enclosed items. · FR-PU07/FR-PU07BB common · FR-PU07BB only * Batte ries a re not enc losed. P leas e p[...]
-
Page 14
5 1 Unpacking and Product Confir mation 1.2.2 Appearance and pa rts identification Unpack the parameter unit, check the name plate on the back, and make sure that the product has not been damaged before using. FR-PU07 Front Rear Bottom 60.00 Hz STF FWD PU READ : List Monitor Liquid crystal display (16 characters 4 lines with backlight) Interactive [...]
-
Page 15
6 Unpacking and Product Confirma tion FR-PU07BB Front Rear 0.00 Hz STF FWD PU READ :List Bottom Operation keys POWER lamp Lit when the power turns ON. ALARM lamp Lit to indicate an inverter fault occurrence. Rating plate Power supply switch Set to ON when using in the battery mode. OFF ON Power supply switch To p Connector for PU cable Connect usin[...]
-
Page 16
7 1 Unpacking and Product Confir mation 1.2.3 Explanation of k eys Key Description Used to se lect th e paramete r setting mode. Press to sel ect the parameter se tting mo de. Used to di splay t he first prior ity scre en. Used to di splay t he output fr equen cy when making an initial se tting. Oper ation cance l key . Used to dis play the functi [...]
-
Page 17
8 Unpacking and Product Confirma tion Fo rwa rd r ota tion c om ma nd ke y . Reverse rot atio n command key . · S top c omma nd ke y . · Used to reset the inverter when a fault occurs. · Used to write a set value in the setting mode. · Used as a cl ear key i n the all parame ter cle ar or alarm history cl ear mod e. · Used as a de cimal poi nt[...]
-
Page 18
9 1 Installation and Removal of FR-PU07 1.3 Installat ion and Remova l of FR- PU07 T o ensure safety , install or remove FR-PU07 after switching the power of the inverter OFF . FR-PU07 cannot be directly inst alled to the FR-E700, D700 inverter . 1.3.1 Direct installat ion to the i nverter ( A700/F700 s eries) (1) Remove the operation p anel (FR-DU[...]
-
Page 19
10 Installation and Removal of FR-PU07 1.3.2 Removal f rom the inve rter (A 700/F700 series) Loosen the fixed screws, hold down the right and lef t hooks of the FR-PU07, and then pull the p ar ameter unit toward you. S T F F W D P U Press the hooks. S T F F W D P U Fixed screw[...]
-
Page 20
11 1 Installation and Removal of FR-PU07 1.3.3 Installation using th e connection cable (FR-CB2) • For the FR-A700/FR-F700 (1) Remove the operation p anel (FR-DU07). ( 2 ) Securely insert one end of connec tion cable into t he PU connector o f the inverter and the other end into the conne ction connector o f FR-PU07 along the guides until the st [...]
-
Page 21
12 Installation and Removal of FR-PU07 • For FR-E700 (1) Open the PU connect or cover . ( 2 ) Securely insert one end of connec tion cable into t he PU connector o f the inverter and the other end into the conne ction connector o f FR-PU07 along the guides until the st oppers are fixed. CAUTION Do not connec t the conn ection cabl e when th e fro[...]
-
Page 22
13 1 Installation and Removal of FR-PU07 • For FR-D700 (1) Rem ove th e inver ter front cover . (For the re moval of th e fron t cover , refer t o the in verter manual.) (2) Securely insert one end of connection cable into t he PU connector of the inverter and the other end into the connection connector of FR-PU0 7 along the guides until the stop[...]
-
Page 23
14 Connection and Removal of FR-PU07BB 1.4 Connec tion and Re moval of FR-PU 07BB 1.4.1 Before using FR-PU07BB in the battery mode For the power supply of FR-PU07BB, a battery and an AC adapter (sold sep arately) are available. (1) When using a battery 1) Loos en the scr ew of the FR- PU07BB r ear side . 3) Place ba tteries as sh own bel ow . 2) Pu[...]
-
Page 24
15 1 Connection and Removal of FR-PU07BB (2) When using an AC adapter 1) Pul l out the prot ectiv e co ver t oward you t o remo ve and then insert the output plu g of an AC adapt er (sold s eparatel y) into the A C a dapter conn ector . 2) Con nect the A C adapter (sold separat ely) to a A C p ower supply . Connector Protective cover STF FW D PU[...]
-
Page 25
16 Connection and Removal of FR-PU07BB REMARKS · Discon nectio n of the con nector can be preve nted by catching the cab le with the h ook of the parameter unit. · When u sing a recha rgeab le bat tery , use the rec harge able ba ttery charged with t he cha rger sp ecified by the battery m anufa cturer. Batter y chargi ng is n ot availa ble with [...]
-
Page 26
17 1 Connection and Removal of FR-PU07BB 1.4.2 Instructions fo r the FR-PU0 7BB (bat tery mode) (1) Functions available when using i n the battery mode (2) FM/AM calibration parameter ( Pr .900 , Pr .901 ) cannot be set (calibrated). (3) For following calibration parameters, only t he adjus ting method without application of analog voltage (current[...]
-
Page 27
18 Connection and Removal of FR-PU07BB 1.4.3 Connecting to FR-A700/F700 using the connection cable (FR-CB2) (1) Remove the operation panel (FR-DU07). (2) Insert one end of connection cable securely into the PU connector of the inverter and the other end i nto the connection connector of FR-PU07BB along t he cable guides until the stoppers are fixed[...]
-
Page 28
19 1 Connection and Removal of FR-PU07BB 1.4.4 Connecting to FR-E700 using the connection cable (FR-CB2) (1) Open the PU cover of the inverter. (2) Insert one end of connection cable securely into the PU connector of the inverter and the other end i nto the connection connector of FR-PU07BB along t he cable guides until the stoppers are fixed . (3)[...]
-
Page 29
20 Parameters to be Checked First 1.5 Parameter s to be Checke d First Change the following p arameter settings as required. For the changing procedures, refer to page 3 3 . 1.5.1 PU display langua ge selection (Pr. 145) By setting the Pr . 145 P U display languag e selectio n value, you can select the language displaye d on the parameter unit. * W[...]
-
Page 30
21 1 Parame ters to be Check ed Firs t 1.5.3 PU contrast adjustment (Pr. 991) By setting the Pr . 99 1 PU cont rast ad just ment value, you can adjust the contrast for the display panel of the parameter unit. Pr . 991 Setting Description 0 to 63 「 0 」「 63 」 Light Dark 「 58 」 Initial value[...]
-
Page 31
22 2 FUNCTI ONS 2.1 Monit oring Fun ctio n 2.1.1 Display overv iew (1) Main monitor Shows the output frequency , output current, output voltage, alarm history and other monitor dat a. · Using to change to the next screen (R efer to page 2 5) · Using to change to the next screen ( Refer to page 59 ) · Using the parameter "PU main display dat[...]
-
Page 32
23 Monitoring Function 2 (4) Operation mode indication Displays the st atus of the operation mode. EXT : External operation mode PU : PU operation mode EXTj : External Jog mode PUj : PU Jog mode NET : Network operation mode PU+E : External/PU combined operation mode (5) Unit indication Shows the unit of the main monitor . (6) W arning indication Di[...]
-
Page 33
24 Monitoring Function REMARKS · S tandby mo de f unction When FR -PU0 7BB gets into the stan dby mode , the back light of the parameter un it turns OF F , and POW ER LE D rem a in s lit . <Switching conditions> ·Whe n the FR-PU 07BB is left in the po wer-ON status for one minu te witho ut conne cting to the in verter . ·Whe n FR-PU07 BB i[...]
-
Page 34
25 Monitoring Function 2 2.1.2 Using " SH I FT" to change th e main monitor When "0" (initial value) is set in the Pr . 52 DU/PU main display data selection , simply pressin g calls 6 different monitor sc reens in sequence. Output frequency monitor Output current monitor 1 UVT 5 3 7 2 OC1 6 4 8 Output voltage monito r Alarm hist[...]
-
Page 35
26 Monitoring Function 2.1.3 S etting the pow er-ON monitor (the first priority monitor) Set the monitor which appears first when power is switched ON or i s pressed. • When you press during any monitor screen other than ALARM HISTOR Y being displayed, that screen is set as the power-ON screen and will be disp layed first.[...]
-
Page 36
27 Monitoring Function 2 2.1.4 Using " READ" to change th e main moni tor Press to display the monitoring list while the main monitor is displayed. Select a monitor from the monitoring list to change the mai n monitor . Exampl e: Sele ct the output curren t peak va lue mon itor . *1 The selected monitor i s not set as the firs t priority [...]
-
Page 37
28 Monitoring Function 2.1.5 Using the parameter to ch ange the monitor (Pr. 52 ) T o change the third monitor (output voltage monitor), set Pr . 52 DU/PU main dis play data selection . (Note that setting "17" (load meter) *2 , "18" (Motor excitation current) *1 * 2 , and " 24" (Motor load ratio) change the output curr[...]
-
Page 38
29 Monitoring Function 2 * The monitor displayed at powering ON is the first priority monitor . Refer to pa ge 26 for the setting method of the first priority monitor . 1) For the set value of "17, 18, 24", thei r monitors are displayed at the second monitor instead o f output current monitor . 2) For the set value of "19 to 23, 25 ?[...]
-
Page 39
30 Frequency Setting 2.2 Frequenc y Sett ing The frequency in PU operation mode and External /PU combined operation mode ( Pr . 79 = "3") can be set. 2.2.1 Direc t setting Directly enter a frequency setting using to . • Operation procedure (Changing from 0Hz setting to 60Hz setting) * If you entered an inc orre ct value , press t o retu[...]
-
Page 40
31 Frequency Se tting 2 2.2.2 Step setting Chang e freque ncy con tinuousl y using / . Y ou can cha nge th e frequ ency on ly while y ou press / . Since the fre quenc y chan ges slowl y at firs t, this set ting can b e us ed f or fi ne adjus tme nt. 1 Press . The frequency setting screen appears. 2 Press / to enter a desired value (60.00Hz ). Y ou [...]
-
Page 41
32 Frequency Setting 2.2.3 Precautions for frequenc y setting 1) Pr . 79 Operation mode selection must have been set to switch to the PU operation. (Refer to the inverter instruction manual for detai ls of Pr . 79 .) 2) In the monitor mode, you cannot make the direct setting (Refer to page 30) to set the r unning frequency . Perform the step settin[...]
-
Page 42
33 Setting and Changing the Parameter Va lues 2 2.3 Setting and Chang ing th e Parameter Values Using the FR-PU07/FR-PU07BB allows you to read the p arameter of inverter or change the set v alue easily . Refer to the inverter instruction manual for details of the parameters. 2.3.1 Specifying the parameter number to c hange the se t value Example: W[...]
-
Page 43
34 Setting and Changing the Pa rameter V alues 2.3.2 Selecting the para meter from functional list to c hange the set val ue Example: When changing 5s to 180s at the Pr . 8 Deceleration time setti ng 1 Press . The frequency setting screen appears, and operation mode changes to PU operation mode. 2 Press . The parameter unit is in the parameter sett[...]
-
Page 44
35 Setting and Changing the Parameter Va lues 2 * If is p ressed w hen an incorr ect setting v alue is input, the display return s to the list display "8". 10 (1) Direct setti ng Press . * Enter the desired v alue. Or (2)S tep setting Press . Display "180" using . 11 Press . The set value is changed. 12 Press to display the ne x[...]
-
Page 45
36 Setting and Changing the Pa rameter V alues 2.3.3 Selecting t he paramet er from parameter list to c hange the se t value Example: When changing 5s to 180s at the Pr . 8 Deceleration time setting * If is press ed wh en an inco rrect s etting valu e is input, the di splay re turns to th e list display "5 ". 1 Press . The frequency setti[...]
-
Page 46
37 Setting and Changing the Parameter Va lues 2 2.3.4 Selecting t he paramet er from User List t o change the set value If a parameter is registered to User List, the parameter can be read from User List and changed. (F or registering the user group, refer to page 3 9 .) Example: When changing 5s to 180s at the Pr . 8 Deceleration time setting * If[...]
-
Page 47
38 Setting and Changing the Pa rameter V alues 2.3.5 Precautions for se tting write · Perform parameter setting change during an inverter stop basically in the PU operation mode or combined operation mode. The p arameter setting can not be changed in the External operation mode or during inverter operation. (Read is performed independently of the [...]
-
Page 48
39 User Group Function 2 2.4 User Gr oup Functi on · User group function is a function to display only parameters necessary fo r setting. · Among all parameters, max imum 16 parameters can be registered to the user group. When "1" is set in Pr . 1 60 , only parameters registered in the user group can be accessed for reading and writing.[...]
-
Page 49
40 User Group Function 2.4.1 Registering the parameters to user group 1 Press . The parameter unit is in the parameter setting mode. 2 Read the par ameters. Ente r th e par amet er numb er to be reg istered to the use r group wi th the numb er keys and press to read t he para meter setting. 3 Set the p arame ters. When ch angi ng the set valu e, e [...]
-
Page 50
41 User Group Function 2 2.4.2 Deleting the para meters from user group 2.4.3 Confirming the parameters registered to use r group 1 Press . The parameter unit is in the parameter setting mode. 2 Select "Us er List". Using / , point the cursor t o "3 User List" and press . 3 Sel ect the par amet er t o be deleted. Using / , point[...]
-
Page 51
42 Calibration of the Mete r (Frequenc y Meter) 2.5 Calibrat ion of the Met er (Freque ncy Meter) The functions vary with the inverter . (Refer to the inverter instruction manual for details of the parameters.) 2.5.1 Calibration of the FM terminal This section provides the way to calibrate the full- scale of meter connected to terminal FM using the[...]
-
Page 52
43 Calibration of the Meter (Frequency Mete r) 2 2.5.2 Calibration of t he AM terminal This section provid es a way to calib rate the meter conn ected to term inal AM using t he p aramete r unit. (1) Calibration proc edure 1 (Example: T o calib rate the met er at th e running frequenc y of 60Hz) 7 Press . Calibration is com plete. 8 Press to r etur[...]
-
Page 53
44 Calibration of the Mete r (Frequenc y Meter) (2) When calibrating out put current For the output current or another item, which does not easily point 100% value during operation, adjust the reference vol tage output, then select the item to be displayed. 4 Enter and press . 60Hz is set. 5 Press . Forward rotation is per formed at 60Hz. Y ou need[...]
-
Page 54
45 Calibration of the Meter (Frequency Mete r) 2 6 Enter and press . The present Pr . 901 setting appears. 7 Enter and press . The setting of maximum running frequency is comp lete . 8 Press . Forward rotation is per formed at 60Hz. Y ou need not co nnect the motor to m ake adjust ment. 9 Using / , adjust the voltage across terminals AM-5 and press[...]
-
Page 55
46 Adjustment of the Frequency Setting Signa ls "Bias" and "Gain" 2.6 Adjustmen t of the Freque ncy Setting Signals "Bias" and "Gain" The functions vary with the inverter model. (Refer to the inverter instruction manual for details of the functions.) 2.6.1 Adjustment procedure There are three ways to adjust t[...]
-
Page 56
47 Adjustment of the Fre quency Setting Signals "Bias " and "Gain" 2 (1) Adjust only the bias and gain frequencies and not adjust the voltage • Setting of the frequency setting voltage bias 1 Press . The frequency setting screen appears, and operation mode changes to PU operation mode. 2 Press . The parameter unit is in the pa[...]
-
Page 57
48 Adjustment of the Frequency Setting Signa ls "Bias" and "Gain" • Setting of the frequency setting voltage gain The adjustment of the frequency s etting volt age bias and gain is c omplete. 6 Press . The present s etting appears. 7 Enter . V oltage need not be applied across t erminals 2-5. 8 Press . The bias frequency is se[...]
-
Page 58
49 Adjustment of the Fre quency Setting Signals "Bias " and "Gain" 2 (2) Adjust any poin t by application of voltage to across terminals 2-5 • Setting of the frequency setting volt age bias 1 Press . The frequency setting screen appears, and operation mode changes to PU operation mode. 2 Press . The parameter unit is in the pa[...]
-
Page 59
50 Adjustment of the Frequency Setting Signa ls "Bias" and "Gain" • Setting of the frequency setting volt age gain The adjustment of the frequency s etting voltage bias and gain is complete. 9 Press , then . The present Pr . 903 setting appears. When the set voltage is changed, the % value also changes. The value s elected in [...]
-
Page 60
51 Adjustment of the Fre quency Setting Signals "Bias " and "Gain" 2 (3) Adjust any point without application of voltage to across terminals 2-5 • Setting of the frequency setting v oltage bias 1 Press . The frequency setting screen appears, and operation mode changes to PU operation mode. 2 Press . The parameter unit is in th[...]
-
Page 61
52 Adjustment of the Frequency Setting Signa ls "Bias" and "Gain" • Setting of the frequency setting v oltage gain The adjustment of the frequency s etting voltage bias and gain is complete. 9 Press , then . The present Pr . 903 sett ing value appears. When the set voltage is changed, the % value also changes. The value s elec[...]
-
Page 62
53 3 3 FUNCTI ON MENU 3.1 Overview of Fu nction Menu Press in any operation mode to call the function menu, on which you can perform various func tions. 3.1.1 Function menu Function M enu Desc ripti on Refer T o 1. MONI TOR FR-PU07 The monitor list appears, and you can change f rom one monitor to another and set the first priority monitor . Page 5 [...]
-
Page 63
54 Overview of Functio n Menu 3. Pr .List The parameter menu appears, and you can perf orm "parameter setting", "list display", "parameter change list display" and "initial value list display". Page 6 2 4. Pr .Clear The parameter clear m enu appears, and you can perform "parameter clear" and "a[...]
-
Page 64
55 Overview of Function M enu 3 3.1.2 Function menu transition *1 C annot be monitore d for the F R-E700 and FR-D70 0 series . *2 Cann ot be mon it ored f or the FR -F70 0 and FR- D700 seri es. *3 Can be moni tored f or t he FR -F700 ser ies w ith the 75K o r more . Frequency [Hz] Current [A] Voltage [V] Fault description * The latest 8 faults are [...]
-
Page 65
56 Overview of Functio n Menu 2 Pr.List 1 Setting Mode 3 Set Pr.List 4 Def.Pr.List SETTING MODE 0~9:Ser Pr.No. Select Oper 2 Pr.List 1 Appl.Grp 3 User List 4 Param Copy 1 Max.F1 0 Trq Bst1 2 Min.F1 3 VFbaseF1 SET Pr.LIST 15 JOG F 15.00 79 Oper 1 125 2Freq 50.00 DEF.Pr.LIST 0 Trq B 6.0 1 Max.F 120.00 2 Min.F 0.00 15 JOG F 15.00Hz 0~400 2 1 3 Pr.List[...]
-
Page 66
57 Overview of Function M enu 3 2 1 3 4 5 6 7 INV.Reset 8 T/Shooting 9 S/W 10 11 12 INV.RESET Exec<WRITE> Cancel<ESC> 2 M.Spd Error 1 M.Not Run Error? V/f Setting See Pr.3,14, 19,47,113 0.00Hz INV.Output 0.00A 0.0V <SHIFT> 3 M.A/Dec Err 4 M.Curr.High NO I/P Power M.NOT RUNNING or Phase Loss Set 5.0S 0 60.00Hz Set 5.0S 60.00Hz 0 St[...]
-
Page 67
58 Overview of Functio n Menu :Select Char Name: 0 00 READ:Decide Char WRITE:DecideName 9 11 Option 2 1 3 4 5 6 7 8 10 Selectop 12 PRCpy set RM : 1 RL : 0 RH : 2 RT : 3 OP1: ---- <option> OP2: ---- OP3: A7NC 2 Copy area 2 1 Copy area 1 3 Copy area 3 1 Read VFD Copy area 1 2 Write VFD 3 Verifing 000 Overwrite area 1 WRITE:Executing ESC:Cancel [...]
-
Page 68
59 Operation Procedure s for Functions 3 3.2 Operati on Proced ures for Functi ons 3.2.1 Monitor function The monitoring list ap pears and you can change from one monitor screen to another and set the first priority screen. 1 Press . The function menu is called. 2 Make su re that t he cursor is locat ed at "1 MONITOR". If not, move the cu[...]
-
Page 69
60 Operation Procedure s for Functions 3.2.2 Selection of PU opera tion (direct input) Y ou can select the PU operation mode to set PU operation frequency . 1 Press . The function menu is called. 2 Using , move the cursor to "2 P U Oper". 3 Press . The menu on the right appears. 4 Make su re that t he cursor is locat ed at "1 PU: Dir[...]
-
Page 70
61 Operation Procedure s for Functions 3 3.2.3 Selection of the PU Jog ope ration mode Y ou can select the PU Jog operation mode to set PU jog frequency . 1 Press . The function menu is called. 2 Using , move the cursor to "2 P U Oper". 3 Press . The menu on the right appears. 4 Using , move the cursor to "2 JOG: Jogging". 5 Pre[...]
-
Page 71
62 Operation Procedure s for Functions 3.2.4 Param eters When selecting the p arameter on the function menu, the parameter menu is displayed, and you can perform the following operations for the p arameters. Display Description 1 Sett in g Mode Swit ches to t he pa ramet er se tt ing mode t o re ad an d wr ite t he pa ramet er se tt ing. 2 Pr . Lis[...]
-
Page 72
63 Operation Procedure s for Functions 3 (1) " 1 Setting Mode" (2) "2 Pr .List " Press to move to the next parameter . 1 Press . The function menu is called. 2 Using , mo ve the cursor to "3 Pr . List". 3 Press . The parameter menu appears. 4 Press . The parameter unit switches to the set ting mode. Re fer to pa ge 33 [...]
-
Page 73
64 Operation Procedure s for Functions (3) Display of "3 S et Pr .List" (4) Display of "4 Def.Pr .List" The initial values of p arameters are displayed. 1 Cal l th e param eter men u similar ly to step s 1 to 3 of page 6 3 . 2 Using / , move th e cursor to "3 Set Pr . List" . 3 Press . The change list appears. When the[...]
-
Page 74
65 Operation Procedure s for Functions 3 3.2.5 Paramet er cl ear Y ou can perform the "parameter clear" and "all parameter clear". Switch to the PU operation mode before performing any operation. • Clear Pr . .......................... Returns (initializes) the parameters to the factory settings with the exception of the some [...]
-
Page 75
66 Operation Procedure s for Functions (2) All parameter clear 1 Cal l th e param eter men u similar ly to step s 1 to 3 of page 6 5 . 2 Select the "Clear Al l". Using / , move the cursor to "2 Clear All" and pres s the . 3 "Clear All" is selected, and the confirmation screen for clearing execution is displayed. 4 Pres[...]
-
Page 76
67 Operation Procedure s for Functions 3 3.2.6 Alarm history Shows the history of p ast eight faults. 1 Press . The function menu is called. 2 Using / , move th e cursor to "5 Alarm His ". Hold down and press / to shift one sc reen. 3 Press . The fault history appears. 4 Press . The running frequency at fault occurrence is displayed. 5 Pr[...]
-
Page 77
68 Operation Procedure s for Functions 3.2.7 Alarm clear Clears all the fault history . 1 Press . The function menu is called. 2 Using / , move th e cursor to "6 AlarmC lear". Hold down and press / to shift one sc reen. 3 Press . " AlarmClear " is selected, and the confirmation screen for clearing is displayed. 4 Press . The fau[...]
-
Page 78
69 Operation Procedure s for Functions 3 3.2.8 Inverte r reset Resets the inverter . 1 Press . The function menu is called. 2 Using / , move th e cursor to "7 INV . Reset". Hold down and press / to shift one sc reen. 3 Press . " INV . Reset " is selected, and the confirmation screen for reset is displayed. 4 Press . The inverter[...]
-
Page 79
70 Operation Procedure s for Functions 3.2.9 Troubleshooting If the inverter appears to operate im properly , perform the following operation to display the most likely cause of the fault. This operation may also be performed during inverter operation (PU operation, External operation) or during trip (protection activated). 1 Press . The function m[...]
-
Page 80
71 Operation Procedure s for Functions 3 T r oubleshooting guidance 1) M.NOT RUNNING (Motor does not run) The protective function is activated to bring the inverter to trip. Press to display the cause of the trip. The inverter's main circuit power has decreased or a phase in the power supply is lost. Check the power supply. Both start signals [...]
-
Page 81
72 Operation Procedure s for Functions 2) M.SPEED ERROR (S peed does not match the running frequency setting) 3) M.A/Dec Err (Actual acceleration/decelerati on time is longer than the Pr . 7/Pr . 8 setting) M. SPEED ERROR SetF MinF1 60.00Hz Pr.2 Since the running frequency setting is higher than the maximum frequency ( Pr. 1 ) setting, the running [...]
-
Page 82
73 Operation Procedure s for Functions 3 4) M.Curr .High (Inverter output current is larger than normal) REMARKS <When the faul t could not be identifie d> When t he caus e of the fault is not speci fied even after p erformi ng the ope ration me ntione d above, the curr ent runn ing freque ncy , ou tput curr ent and out put voltage a t the po[...]
-
Page 83
74 Operation Procedure s for Functions 3.2.10 Terminal assignment (Se lectop) The signals assigned to the control circuit term inals and their ON-OFF state are display ed. If the plug-in options FR-A7AX, FR-A7A Y and FR-A7A R are mounted, the terminal state of the plug-in option can be also confirmed. 1 Press . The function menu is called. 2 Using [...]
-
Page 84
75 Operation Procedure s for Functions 3 3.2.11 Opt ion Displays what options are fitted to the option c onnectors. 1 Press . The function menu is called. 2 Using / , move th e cursor to "1 1 Option". Hold down and press / to shift one sc reen. 3 Press . Numbers O P1 to OP3 correspond to nu mbers 1 to 3 of the option slot on the inverter [...]
-
Page 85
76 Operation Procedure s for Functions 3.2.12 Multiple copies (1) Copying the para meter settings Parameter settings of an inverter can be read. The settings of maximum three inverters can be stored in the FR-PU07. Y ou can also copy the stored parameter settings to another inverter of the same series. Confirm for set ting · Is the PU operation mo[...]
-
Page 86
77 Operation Procedure s for Functions 3 • Reading the parameter settings of the inverter and storing them to FR-PU07. 1 Connect the F R-PU07 to t he copy source inverter. 2 Press . The function menu appears. 3 Sele ct th e " PRC py set". Using / , mo ve the cursor to "12 PRCpy s et" and press . 4 Selec t the c opy area . The [...]
-
Page 87
78 Operation Procedure s for Functions • Writing the parameter setting stored in FR-PU07 to the inverter 1 Connect the F R-PU07 to the copy dest ination inverter . 2 Press . The function menu appears. 3 Sele ct th e " PRC py set". Using / , mo ve the cursor to "12 PRCpy s et" and press . 4 Select the copy area. Point the curso[...]
-
Page 88
79 Operation Procedure s for Functions 3 (2) V erifying t he parameters All the parameter settings stored in the FR-PU07 are verified with those which are stored in the inverter . REMARKS V erification can not be per formed betwe en d ifferent in verter series. 1 Re fer to pa ge 77 and copy the paramet er settings of the verify s ource inverter t o[...]
-
Page 89
80 Operation Procedure s for Functions 9 If an error is detected during verification, the correspondin g Pr . is shown. Note that only "V erify Err" will be displayed if an incorrect value has been entered directly (f se tting) or set in either Pr . 17 3 or Pr . 174 . 10 Press . When verification is stopped with verification error , press[...]
-
Page 90
81 Other Precaut ions 3 3.3 Other Preca utions 3.3.1 Precautions for parameter unit opera tion Note the following items when operating the p arame ter unit to prevent setting from being disabled or incorrect values from being entered. • Precautions for the digit count and deci mal point of input value The max imum num ber of input digits is six i[...]
-
Page 91
82 4 OPERATION 4.1 How to Sel ect the O peration M ode 4.1.1 Switchi ng from Exte rnal operation mode [EXT] to PU operation mode [PU] Pressing switches to the PU operation mode and changes the o peration mode indication to [PU]. 4.1.2 S witching from PU operation mode [PU] to External operation mode [EXT] Pressing s witche s to the E xternal operat[...]
-
Page 92
83 How to Se lect th e Operat ion Mode 4 4.1.3 Switching to the Ex ternal / PU combine d operation mode Changing the Pr . 79 Operation mode selection setting to "3" or "4" switches to th e External / PU combined operation mode. "PU+E" is displayed in the operation mode indication pos ition. The relationship between the[...]
-
Page 93
84 How to Operat e PU Op eration 4.2 How to Oper ate PU Ope ration 4.2.1 Normal operation During motor operation, the speed can be changed by simply executing S tep 2. Step Operation Procedure Image 1 Switch power ON. Make sure that the monitor appears. 2 Set the r unning frequency . Set the running frequency using direct setting or step setting. ([...]
-
Page 94
85 How to Op erate P U Oper ation 4 4.2.2 PU Jog operat ion Hold down or to perform operation, and release it to stop. Jog operation cannot be performed in the following cases: · During motor operation · The Pr . 15 Jo g frequenc y is less than the Pr . 13 Starting frequenc y . Example: T o operate at the PU Jog running frequency of 8Hz Ste p Ope[...]
-
Page 95
86 Combined Operation (Operation Using External Input Signals and PU ) 4.3 Com bined Operation (Operation Using External Input S ignals and PU ) 4.3.1 Entering the start signal from outside and se tting the running frequency from the PU ( Pr. 79 = 3) The extern al frequency setting signals an d and of the pa rameter unit are n ot accepted . S top w[...]
-
Page 96
87 Combined Operation (Operation Using External Input Signals and PU) 4 4.3.2 Entering the running frequency from outsi de and making start a nd stop from the PU ( Pr. 79 = 4) Ste p Oper ation Procedure Image 1 Switch t he powe r ON. 2 Set "4" in Pr . 79 Operat ion mode se lect ion . The External/PU combined operation mode is selected and[...]
-
Page 97
88 Combined Operation (Operation Using External Input Signals and PU ) 4.3.3 Entering the start signal and mul ti-speed signal from outside and setting multiple speeds from the pa rameter unit Ste p Operation Procedure Image 1 Switc h th e pow er ON. 2 Select th e multi-s peed signal requ ired for oper ati on. Switch the RH, RM or RL signal ON. 3 S[...]
-
Page 98
89 5 5 CHECK FIRST W HEN YOU HAVE A TROUBLE 5.1 Tro ubleshooti ng If a fault occurs and the inverter fails to operate properly , locate the cause of the fault and tak e proper corrective action by referring to the troubleshooting below . If the corresponding information is not found in the table, the inverter has problem, or the component p arts ar[...]
-
Page 99
90 Troubleshooting The "MITSUBISHI" display remains on an d it will no t accept op eration. During inverter reset Check whe ther RES si gnal is ON T urn OFF the RES sign al. Conn ecti on fault of a cabl e or connect or Check that no cable d amag e nor connec tion faul t of a connect or is found. Repl acement o f a c abl e Check for a conn[...]
-
Page 100
91 6 6 SPECIFICATIONS 6.1 Standa rd Sp ecificat ions *1 At the lo w tem peratur es o f less than about 0 ° C, the liquid cr ystal displ ay (LCD) may be sl ower in ope ration . At high temp erat ures , t he LC D li fe may be come short er . *2 T e mperat ures app licable f or a short tim e, e.g. in tr ansit. Item S pecifica tions FR-PU07 FR-PU07BB [...]
-
Page 101
92 Stand ard Spec ification s • FR-PU 07BB d edicated specific ations * The batt ery life is a re ferenc e value. It differs dep endi ng on the bat tery an d the usage . Item Specific ations Battery life * Alkaline batter y Nick el metal hydride battery A700/F700 E700 A7 00/F700 E 700 Battery life Approx. 90 min Approx. 150 min Approx. 120 min Ap[...]
-
Page 102
93 Outline Drawing and Panel Cutting Drawing 6 6.2 Outli ne Dra wing a nd Pan el Cut ting Dr awing 6.2.1 FR-PU07 outline dimension dra wings 80.3 (14.2) 2.5 50 (1 1.45) 25.05 135 83 67 51 40 56.8 57.8 26.5 4-R1 Mounting hole 4- 4 hole (V alid screw depth 5.0) M3 screw *2 26.5 40 <Outline drawing> <Panel cutting drawing> *1 *1 *1 *1 *1 W[...]
-
Page 103
94 Outline Drawing and Panel Cutting Drawing 6.2.2 FR-PU07BB outline dimension draw ings <Outline drawing> 8.2 46.7 44.7 46.7 135 83 18 6 (Unit: mm) * FR-PU07BB cannot be installed t o the enc losure and such .[...]
-
Page 104
95 APPENDIX Appendi x 1 Disposing of the e quipment in the EU coun tries • The symbol shown below, which is printed on the product for EU countries, means that electric and electronic equipment, at their end-of-life, should be disposed of separately from your household was te. • Please, dispose of this equipment at your local commu nity waste c[...]
-
Page 105
96 REVISIONS *The ma nual nu mber is gi ven on the bottom left of the back co ver . Print Date *Manual Number Revision Aug., 2 005 IB(NA)-0600 240ENG -A First edition May , 2007 I B(NA)-0 60024 0ENG-B · FR -PU07B B · Dispos ing of the equ ipmen t in EU countr ies Mar ., 2008 IB( NA)-0600 240ENG -C ·Part ial change s Jan., 200 9 IB(NA)-0600 240EN[...]