Go to page of
Similar user manuals
-
Air Conditioner
Mitsumi electronic LGH-F470RX3-E
4 pages 1.27 mb -
Air Conditioner
Mitsumi electronic 30
36 pages 2 mb -
Air Conditioner
Mitsumi electronic MUY-GANA
40 pages 0.28 mb -
Air Conditioner
Mitsumi electronic PKA-A18HA4
36 pages 2.2 mb -
Air Conditioner
Mitsumi electronic PLA-A24AA
44 pages 1.67 mb -
Air Conditioner
Mitsumi electronic MUZ-GENA
40 pages 0.28 mb -
Air Conditioner
Mitsumi electronic MXZ-ANA
40 pages 0.28 mb -
Air Conditioner
Mitsumi electronic MUZ-GANA
40 pages 0.28 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Mitsumi electronic PLA-A18AA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mitsumi electronic PLA-A18AA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Mitsumi electronic PLA-A18AA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Mitsumi electronic PLA-A18AA should contain:
- informations concerning technical data of Mitsumi electronic PLA-A18AA
- name of the manufacturer and a year of construction of the Mitsumi electronic PLA-A18AA item
- rules of operation, control and maintenance of the Mitsumi electronic PLA-A18AA item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mitsumi electronic PLA-A18AA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mitsumi electronic PLA-A18AA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mitsumi electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mitsumi electronic PLA-A18AA.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Mitsumi electronic PLA-A18AA item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SER VICE MANUAL SPLIT -TYPE, HEA T PUMP AIR CONDITIONERS SPLIT -TYPE, AIR CONDITIONERS No. OC370 REVISED EDITION-B CONTENTS 1. TECHNICAL CHANGES ··································2 2 . REFERENCE MANUAL ······································2 3. SAFETY PRECAUTION ·······?[...]
-
Page 2
2 1 TECHNICAL CHANGES 2 REFERENCE MANUAL Service Ref. PUZ-A18/24/30/36/42NHA PUZ-A18/24/30/36/42NHA-BS PUY -A12/18/24/30/36/42NHA (1) PUY -A12/18/24/30/36/42NHA (1) -BS Service Manual No. OC367 2-1. OUTDOOR UNIT SERVICE MANUAL Series (Outdoor unit) PUZ-A·NHA(-BS) PUY-A·NHA(-BS) Manual No . OCS04 2-2. TECHNICAL DA T A BOOK PLA-A12AA ➔ PLA-A12AA [...]
-
Page 3
3 SAFETY PRECAUTION 3 Cautions for units utilising refrigerant R410A 3-2. CAUTIONS RELA TED TO NEW REFRIGERANT Use new refrigerant pipes. Make sure that the inside and outside of refrige- rant piping is clean and it has no contamination such as sulfur hazardous for use, oxides, dirt, shaving particles, etc. In addition, use pipes with specified thi[...]
-
Page 4
4 Gravimeter Unit [3] Service tools Use the below service tools as exclusive tools for R410A refrigerant. No. Specifications 1 Gauge manifold ·Only for R410A ·Use the existing fitting specifications . (UNF1/2) ·Use high-tension side pressure of 5.3MPa·G or over . 2 Charge hose ·Only for R410A ·Use pressure performance of 5.09MPa·G or over . [...]
-
Page 5
5 P ART NAMES AND FUNCTIONS 4 Auto Air Swing Vane Disperses airflow up and down and adjusts the angle of airflow direction. Grille Filter Removes dust and pollutants from intake air. Horizontal Air Outlet Sets horizontal airflow automatically during cooling or dehumidifying. Air Intake Intakes air from room. ● Indoor Unit ● Wired remote control[...]
-
Page 6
6 ● Wired remote controller ● ● ˚F˚C ˚F˚C ERROR CODE AFTER TIMER TIME SUN MON TUE WED THU FRI SA T ON OFF Hr AFTER FIL TER FUNCTION ONL Y1Hr . WEEKL Y SIMPLE AUTO OFF Note: “PLEASE W AIT” message This message is displayed for approximately 3 minutes when power is supplied to the indoor unit or when the unit is recovering from a power [...]
-
Page 7
7 ON/OFF TEMP FAN VANE TEST RUN AUTO STOP AUTO START h min LOUVER MODE CHECK RESET SET CLOCK MODEL SELECT NOT AVAILABLE SWING CHECK FAN TEST RUN ˚F ˚C AMPM STOP START AMPM COOL DRY AUTO FAN HEAT V ANE CONTROL button Changes the air flow direction. CLOCK button RESET button SET button ON/OFF button The unit is turned ON and OFF alternately each ti[...]
-
Page 8
8 Single phase,60Hz, 208/230V 15 1 Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.070 0.79 Dry: 15-16-18-20(530-570-640-710) Wet:14-15-17-19(490-530-600-670) 0(direct blow) – Remote controller & built-in 28-30-32-34 32 (1-1/4) PLA-A18AA/ PLA-A18AA 1 UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (3[...]
-
Page 9
9 UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 840 (33-1/16) PANEL : 950 (37-3/8) UNIT : 298 (11-3/4) PANEL : 30 (1-3/16) UNIT : 30 (66) P ANEL : 5 (11) PLA-A36AA/ PLA-A36AA 1 Single phase,60Hz, 208/230V 15 2 Munsell 0.70Y 8.59/0.97 Plate fin coil Turbo fan (direct) o 1 0.110 1.25 Dry: 20-23-26-28(710-810-920-990) Wet: 19-22-25-27(670-770-880-9[...]
-
Page 10
10 6 NOISE CRITERION CUR VES PLA-A12AA PLA-A12AA 1 NOTCH SPL(dB) LINE High Medium1 Medium2 Low 31 29 28 27 90 80 70 60 50 40 30 20 10 63 125 250 500 1000 2000 4000 8000 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE NC-60 NC-50 NC-40 NC-30 NC-20 NC-70 OCT A VE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µ bar) BAND CENTER FREQUENCIES, Hz P[...]
-
Page 11
PLA-A12AA 1 PLA-A18AA 1 PLA-A24AA 1 PLA-A30AA 1 PLA-A36AA 1 PLA-A42AA 1 11 INDOOR UNIT PLA-A12AA PLA-A18AA PLA-A24AA PLA-A30AA PLA-A36AA PLA-A42AA 7 OUTLINES AND DIMENSIONS Unit : inch(mm) 1-1/2(37) 14-23/32(374) 11/16 (17 ) 2-3/8(60) 11-1/4(286) 1-31/32~2-3/4 4-1/8(105) B A 7-15/32(190) D 3-5/16 (84) 3-5/32 (80) 5/8F 3/8F 24/30/36/42 12/18 1 Liqui[...]
-
Page 12
12 8 WIRING DIAGRAM I.B SWE ON OFF SW2 SW1 Refer to tables 1 and 2 for service PCB. HEATER CN24 ( YLW ) D.SENSOR CN31 ( WHT ) 1 2 3 INTAKE CN20 ( RED ) 1 2 LIQUID CN21 ( WHT ) PIPE CN29 ( BLK ) 1 2 1 2 REMOCON CN22 ( BLU ) 1 2 TH5 TH1 DS TH2 2 1 TB5 R.B TB6 12 TRANSMISSION WIRES DC12V LED3 LED2 LED1 CN41 CN2L CN51 CN32 WIRELESS CN90 ( WHT ) VANE CN[...]
-
Page 13
13 Thermistor TH2 Pipe temperature (Liquid) Distributor with strainer (#50) Thermistor TH5 (Cond./ Eva. temperature) Thermistor TH1 (Room temperature) Refrigerant flow in cooling Refrigerant flow in heating Strainer (#50) Strainer (#50) Heat e xchanger Refrigerant GAS pipe connection (Flare) Refrigerant LIQUID pipe connection (Flare) 9 REFRIGERANT [...]
-
Page 14
14 10 TROUBLESHOOTING <Error code display by self-diagnosis and actions to be taken for service (summary)> Present and past error codes are logged and displayed on the wired remote controller or controller board of outdoor unit. Actions to be taken for service and the inferior phenomenon reoccurrence at field are summarized in the table below[...]
-
Page 15
15 [Procedure] 1. Press the CHECK button twice. 2. Press the temperature buttons. 3. Point the remote controller at the sensor on the indoor unit and press the HOUR button. 4. Point the remote controller at the sensor on the indoor unit and press the ON/OFF button. • "CHECK" lights, and refrigerant address "00" blinks. • Che[...]
-
Page 16
16 [Output pattern A] Errors detected by indoor unit [Output pattern B] E9 *1 If the beeper does not sound again after the initial 2 beeps to confirm the self-check start signal was received and the OPERATION INDICATOR lamp does not come on, there are no error records. *2 If the beeper sounds 3 times continuously “beep, beep, beep (0.4 + 0.4 + 0.[...]
-
Page 17
17 • If the unit cannot be operated properly after the test run has been performed, refer to the following table to find out the cause. Symptom Cause Wired remote controller LED 1, 2 (PCB in outdoor unit) On the wireless remote controller with condition above, following phenomena take place. • No signals from the remote controller can be receiv[...]
-
Page 18
18 Error Code Abnormal point and detection method Cause Countermeasure P1 Room temperature thermistor (TH1) 1 The unit is in 3-minute resume preven- tion mode if short/open of thermistor is detected. Abnormal if the unit does not reset normally after 3 minutes. (The unit returns to normal operation, if it has been reset normally .) 2 Constantly det[...]
-
Page 19
19 Error Code Abnormal point and detection method Cause Countermeasure P6 Freezing/overheating protection is working 1 Freezing protection (Cooling mode) The unit is in 6-minute resume prevention mode if pipe <liquid or condenser/evap- orator> temperature stays under -15 : (5˚F) for 3 minutes, 3 minutes after the compressor started. Abnormal[...]
-
Page 20
20 Error Code Abnormal point and detection method Cause Countermeasure P9 Pipe temperature thermistor / Condenser-Evaporator (TH5) 1 The unit is in 3-minute resume protec- tion mode if short/open of thermistor is detected. Abnormal if the unit does not get back to normal within 3 minutes. (The unit returns to normal operation, if it has been reset [...]
-
Page 21
21 E6 1 Contact failure, short circuit or , miswiring (converse wiring) of indoor/outdoor unit connecting wire 2 Defective transmitting receiving circuit of indoor controller board 3 Defective transmitting receiving circuit of indoor controller board 4 Noise has entered into indoor/ outdoor unit connecting wire. ∗ Check LED display on the outdoor[...]
-
Page 22
22 (For the separate indoor/outdoor unit power sup- ply system) 1 Power supply of 208/230V AC is not supplied to indoor unit. 2 The connectors of the optional replacement kit are not used. 3 Defective indoor controller board 4 Defective indoor power board 10-4. TROUBLESHOOTING BY INFERIOR PHENOMENA Note: Refer to the manual of outdoor unit for the [...]
-
Page 23
23 Note: Refer to the manual of outdoor unit for the detail of remote controller . (3)Upward/downward vane performance failure 1 The vane is not downward during defrosting and heat preparation and when the thermostat is OFF in HEA T mode. (Working of COOL protection function) 2 V ane motor does not rotate. • Defective vane motor • Breaking of w[...]
-
Page 24
24 10-5. EMERGENCY OPERA TION 10-5-1. When wireless remote controller has troubles or its battery is exhausted 1. Emergency operation is available in such a case using emergency operation switch equipped on the grille. 2. T o start operation • Cooling Operation·······Press (Cooling) switch. • Heating Operation·······Press (Heating[...]
-
Page 25
25 1 1 2 2 3 3 Red White Black Parts name Check points Disconnect the connector then measure the resistance using a tester . (At the ambient temperature 10 : (50˚F)~30 : (86˚F)) Measure the resistance between the terminals using a tester . (At the ambient temperature20 : (68˚F)) Measure the resistance between the terminals using a tester . (Wind[...]
-
Page 26
26 0 10 20 30 40 50 -20 -10 0 10 20 30 40 50 -4 -14 32 50 68 86 104 122 : ° F T emperature Resistance (k " ) <Thermistor for lower temperature> <Thermistor Characteristic graph> Room temperature thermistor(TH1) Pipe temperature thermistor/liquid(TH2) Condenser/evaporator temperature thermistor(TH5) Thermistor R 0 =15k ' ±3 %[...]
-
Page 27
27 10-7.TEST POINT DIAGRAM 10-7-1. Power board PLA-A12AA PLA-A18AA PLA-A24AA PLA-A30AA PLA-A36AA PLA-A42AA PLA-A12AA 1 PLA-A18AA 1 PLA-A24AA 1 PLA-A30AA 1 PLA-A36AA 1 PLA-A42AA 1 CNSK Connect to the indoor controller board (CNDK) between 1 to 3 208/230V AC CN2S Connect to the indoor controller board (CN2D) between 1 to 3 12.6-13.7V DC (Pin 1 (+)) O[...]
-
Page 28
28 10-7-2. Indoor controller board PLA-A12AA PLA-A18AA PLA-A24AA PLA-A30AA PLA-A36AA PLA-A42AA PLA-A12AA 1 PLA-A18AA 1 PLA-A24AA 1 PLA-A30AA 1 PLA-A36AA 1 PLA-A42AA 1 CN2D Connect to the indoor power board (CN2S) (12.5~13.7V DC) CNDK Connect to the indoor power board (CNSK) (208/230V AC) FUSE (6.3 A 250 V) CN22 Connect to the terminal block(TB5) (R[...]
-
Page 29
29 SW1 Setting by the dip switch and jumper wire Functions Jumper wire Model settings Capacity settings Pair number setting with wireless remote controller Remarks SW2 J41 J42 Unit type setting JP1 Indoor controller board type setting JP3 0 1 2 3 ~ 9 Wireless remote controller setting Control PCB setting J41 J42 <Initial setting> Wireless rem[...]
-
Page 30
30 DISASSEMBL Y PROCEDURE OPERA TING PROCEDURE PHOTOS & ILLUSTRA TIONS 1. Removing the air intake grille (1) Slide the knob of air intake grille to the direction of the arrow 1 to open the air intake grille. (2) Remove the string hook from the panel to prevent the grille from dropping. (3) Slide the shaft in the hinge to the direction of the ar[...]
-
Page 31
31 OPERA TING PROCEDURE PHOTOS & ILLUSTRA TIONS 6. Removing the panel (1) Remove the air intake grille.(See figure 1) Corner panel (See figure 2) (1) Remove the corner screw . (2) Slide the corner panel to the direction of the arrow 3 , and remove the corner panel. Panel (See photo 5) (1) Disconnect the connector that connects with the unit. (2[...]
-
Page 32
32 OPERA TING PROCEDURE PHOTOS & ILLUSTRA TIONS 9. Removing the heat exchanger (1) Remove the panel. (See photo 5) (2) Remove the bell mouth. (See photo 1) (3) Remove the electrical box. (See photo 2) (4) Remove the drain pan. (See photo 6) (5) Remove the turbo fan. (See photo 3) (6) Remove the 3 screws of the piping cover , and pull out piping[...]
-
Page 33
33 12 P ARTS LIST (non-RoHS compliant) 1 10 2 3 3 4 5 9 8 7 6 3 GEAR GEAR (V ANE) V ANE BUSH V ANE MOTOR ON/OFF CENTRALLY CONTROLLED ERROR CODE CLOCK ON OFF ˚C CHECK CHECK MODE FILTER TEST RUN FUNCTION ˚C 1Hr. NOT AVAILABLE STAND BY DEFROST TEMP. 11 P ANEL P ARTS PLA-A12AA PLA-A18AA PLA-A24AA PLA-A30AA PLA-A36AA PLA-A42AA No. Parts No. Parts Name[...]
-
Page 34
34 No. Parts No. Parts Name Q'ty / set PLA-A·AA 12 18 24, 30 Wiring Diagram Symbol Recom- mended Q'ty 1 2 3 4 5 6 7 8 9 TURBO FAN SPL WASHER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER PIPE TEMPERATURE THERMISTOR CONDENSER / EVAPORATOR TEMPERATURE THERMISTOR MOTOR CAP LEAD ASSY(F/M) FAN MOTOR RUBBER MOUNT R01 E28 114 R01 08K 097 T7W H20[...]
-
Page 35
35 Q'ty / set 36, 42 Specification Remarks (Drawing No.) No. Parts No. Parts Name Wiring Diagram Symbol Recom- mended Q'ty 1 2 3 4 5 6 7 8 9 TURBO FAN SPL WASHER HEAT EXCHANGER PIPE TEMPERATURE THERMISTOR CONDENSER / EVAPORATOR TEMPERATURE THERMISTOR MOTOR CAP LEAD ASSY(F/M) FAN MOTOR RUBBER MOUNT 1 1 1 1 1 1 1 1 4 TH2 TH5 MF D17CP110MS T[...]
-
Page 36
36 No. Parts No. Parts Name Wiring Diagram Symbol Recom- mended Q'ty 1 2 3 4 5 6 7 8 9 10 11 12 13 14 DRAIN PAN DRAIN HOSE DRAIN PUMP DRAIN SENSOR SENSOR HOLDER INDOOR POWER BOARD INDOOR CONTROLLER BOARD ROOM TEMPERATURE THERMISTOR TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK CAPACITOR DRAIN PLUG DRAIN PLUG 1 1 1 1 1 1 1 1 1 1 1 1 1 1 DP DS P.[...]
-
Page 37
37 No. Parts No. Parts Name Wiring Diagram Symbol Recom- mended Q'ty 1 2 3 4 5 6 7 8 9 10 11 12 13 14 DRAIN PAN DRAIN HOSE DRAIN PUMP DRAIN SENSOR SENSOR HOLDER INDOOR POWER BOARD INDOOR CONTROLLER BOARD ROOM TEMPERATURE THERMISTOR TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK CAPACITOR DRAIN PLUG DRAIN PLUG 1 1 1 1 1 1 1 1 1 1 1 1 1 1 DP DS P.[...]
-
Page 38
38 13 RoHS P ARTS LIST 1 10 2 3 3 4 5 9 8 7 6 3 GEAR GEAR (V ANE) V ANE BUSH V ANE MOTOR ON/OFF CENTRALLY CONTROLLED ERROR CODE CLOCK ON OFF ˚C CHECK CHECK MODE FILTER TEST RUN FUNCTION ˚C 1Hr. NOT AVAILABLE STAND BY DEFROST TEMP. 11 P ANEL P ARTS PLA-A12AA 1 PLA-A18AA 1 PLA-A24AA 1 PLA-A30AA 1 PLA-A36AA 1 PLA-A42AA 1 No. Parts No. Parts Name Spe[...]
-
Page 39
39 No. Parts No. Parts Name Q'ty / set PLA-A·AA 1 12 18 24, 30 Wiring Diagram Symbol Recom- mended Q'ty 1 2 3 4 5 6 7 8 9 RoHS G G G G G G G G G G G TURBO FAN SPL WASHER HEAT EXCHANGER HEAT EXCHANGER HEAT EXCHANGER PIPE TEMPERATURE THERMISTOR CONDENSER / EVAPORATOR TEMPERATURE THERMISTOR MOTOR CAP LEAD ASSY (F/M) FAN MOTOR RUBBER MOUNT R[...]
-
Page 40
40 Q'ty / set 36, 42 Specification Remarks (Drawing No.) No. Parts No. Parts Name Wiring Diagram Symbol Recom- mended Q'ty 1 2 3 4 5 6 7 8 9 RoHS G G G G G G G G G TURBO FAN SPL WASHER HEAT EXCHANGER PIPE TEMPERATURE THERMISTOR CONDENSER / EVAPORATOR TEMPERATURE THERMISTOR MOTOR CAP LEAD ASSY(F/M) FAN MOTOR RUBBER MOUNT 1 1 1 1 1 1 1 1 4 [...]
-
Page 41
41 No. Parts No. Parts Name Wiring Diagram Symbol Recom- mended Q'ty 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RoHS G G G G G G G G G G G G G G DRAIN PAN DRAIN HOSE DRAIN PUMP DRAIN SENSOR SENSOR HOLDER INDOOR POWER BOARD INDOOR CONTROLLER BOARD ROOM TEMPERATURE THERMISTOR TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK CAPACITOR DRAIN PLUG DRAIN PLUG 1 1[...]
-
Page 42
42 No. Parts No. Parts Name Wiring Diagram Symbol Recom- mended Q'ty 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RoHS G G G G G G G G G G G G G G DRAIN PAN DRAIN HOSE DRAIN PUMP DRAIN SENSOR SENSOR HOLDER INDOOR POWER BOARD INDOOR CONTROLLER BOARD ROOM TEMPERATURE THERMISTOR TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK CAPACITOR DRAIN PLUG DRAIN PLUG 1 1[...]
-
Page 43
43 OC370B--2.qxp 07.6.20 2:41 PM Page 43[...]
-
Page 44
C Copyright 2006 MITSUBISHI ELECTRIC ENGINEERING CO., L TD. Distributed in Jun. 2007 No.OC370 REVISED EDITION-B PDF 9 Distributed in Aug. 2006 No.OC370 REVISED EDITION-A PDF 9 Distributed in Feb. 2006 No.OC370 PDF 10 Made in Japan New publication, effective Jun. 2007 Specifications subject to change without notice. TM HEAD OFFICE : TOKYO BLDG., 2-7[...]