Monessen Hearth M400BFC manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Monessen Hearth M400BFC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Monessen Hearth M400BFC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Monessen Hearth M400BFC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Monessen Hearth M400BFC should contain:
- informations concerning technical data of Monessen Hearth M400BFC
- name of the manufacturer and a year of construction of the Monessen Hearth M400BFC item
- rules of operation, control and maintenance of the Monessen Hearth M400BFC item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Monessen Hearth M400BFC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Monessen Hearth M400BFC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Monessen Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Monessen Hearth M400BFC.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Monessen Hearth M400BFC item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    647 BFC cover 8/18/00 djt M400BFC Balanced Flue (Closed Combustion) Heat-Circulating Fireplace For use in the U.S. / Canada Underwriter ’s Laboratories Report No. MH7603 DO NOT DISCARD THIS MANUAL: Retain for future use. 87D1505 12/09 Rev . 3 Homeowner ’ s Installation and Operating Manual[...]

  • Page 2

    2 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 M400BFC Listed UL127 / ULC-S610 Standard for Factory Built Fireplaces Safety Information ...................................................................................... 3 Specifications and Framing ....................................................................... 4 Parts Identi[...]

  • Page 3

    3 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Safety Information Please Read This Manual Before Installing and Using Fireplace IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instruc- tions may result in a possible fire hazard and will void the warranty . Description The M[...]

  • Page 4

    4 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 M400BFC Balanced Flue Heat-Circulating Fireplace Fig. 1 M400BFC specifications and framing. 6 " (16mm) 56O " (13mm) 56O " 32 6 " (829mm) 41 (6 " (1064mm) 6 " (16mm) 56QE " (49mm)  " (914mm)  " (533mm) [...]

  • Page 5

    5 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 FP554a BFC Fireplace and chase parts identification circulating model 8/21/00 djt T ermination Cap Storm Collar Pan Flashing Draftstop Standoff Surround T rim Ledge Standoff Glass Door Romex Pigtail Gas Line Access Knock- out (Each Side) Air Inlet Basket Grate Bottom Grille Metal Safety Str[...]

  • Page 6

    6 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 D Rise B G H B Offset C E 6 FT . G H A Hearth Floor Chimney Section CHIMNEY FLUE EXIT Elbow FP269 MBUF 5/16/96 rev . 5/25 TCS8A Support Example 1 Example 2 Example 3 Chimney Requirements - Offset Installations Notes: G + H cannot exceed 20 feet. Air Space Clearances: = 2” Min. to Combusti[...]

  • Page 7

    7 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Planning Information Preplanning an installation is very important to ensure safety and to save time and money . An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting the Fireplace A fireplace may only be mounted on the following sur- [...]

  • Page 8

    8 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30’ (9 m) above the hearth. Chimney supports are required if the vertical height exceeds 30’ (9 m). Locate chimney supports at ceiling holes or other structural framing at 30’ (9 m[...]

  • Page 9

    9 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 FPC555a Platform insulation BFC model 8/21/00 djt Hard Flat Surface Insulation Platform FPC555a Fig. 7 Insulating between platform and fireplace. Framing Framing can be constructed before or after the fireplace is set in place, however , most installers build the frame before setting the fi[...]

  • Page 10

    10 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Offset Installation In order to clear an obstruction, it may be necessary to offset chimney from vertical. This is accomplished by using elbows. Use the 30° Offset Elbow table on Page 5 to determine proper offset and parts required. Each offset requires two (2) elbows. The second elbow is[...]

  • Page 11

    1 1 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1 Zx ” (38 mm), allowing the remainder to extend in front of firebox. Overlap strips at least 1/2” (13 m[...]

  • Page 12

    12 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 14. When you get a good lock, you will hear the pipe clearly snap together . Once sections are snap-locked in place, it is extremely diff[...]

  • Page 13

    13 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Firestop spacers are not available for , nor are they required on vertical walls. DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer . If you seal this area, it may cause a fire hazard. Canadian Requirements for Insulation Shield In Canada, an at[...]

  • Page 14

    14 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 FRONT VIEW SIDE VIEW Air Space Clearances FPC559a BFC AIR SP ACES circulating models 8/21/00 djt Standoff Combustible framing material MUST NOT penetrate AIR SP ACE (shaded areas). 2” Zx ” air space to sides Firestop 1” Air Space to Back Zx ” Air Space to Sides 0” Clearance to [...]

  • Page 15

    15 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 MA81 rev. 8/5/97 1 Zx " Ref. B C Combustible materials are permitted within a shaded area shown in Figure 21 titled Minimum W all Clearances. * * * MA81 Fig. 20 Combustible mantel clearances. * 12” from top of grille opening. ** 6” from top of grille opening. Face Plate FP531b ma[...]

  • Page 16

    16 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Side W all Protection Adjacent combustible side walls that are within mini- mum dimensions shown in Figure 24 of the fireplace opening must be protected with MHSC W all Shield Model SP40 or a specifically built wall shield described in Figure 18. The special wall shield design described in[...]

  • Page 17

    17 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 W ARNING: Hearth extension must be installed in accordance with Figure 23 and must not cover the bottom front opening of the circulating model. Alternate noncombustible materials may be used pro- viding the (total) thermal resistance (Rt value) of the al- ternate material employed is great[...]

  • Page 18

    18 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Installing Line for Gas Logs MHSC fireplaces are designed to accept a 1/2” (13 mm) gas line for installation of an approved gas appliance. (MHSC manufactures a wide variety of gas logs for use in MHSC fireplaces.) Be sure to have the appliance installed in accordance with building codes.[...]

  • Page 19

    19 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 647 BFC parts 2008 2/08 djt 1 2 3 5 6 7 8 9 10 1 1 12 13 14 16 15 19 18 17 4 24 20 22 21 25 23 23 26 27 28 29 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. M400BFC Balanced Flue Fireplac[...]

  • Page 20

    20 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 M400BFC Balanced Flue Fireplace (continued) 17. Blower Assembly - FKSX-A 20000620 18. Grate Retainer 2353179 19. Junction Box Assembly 3126161 20. Ceramic Glass Panel (two per fireplace) 30004352 21. Flat Gasket 3/4” Wide (two per fireplace) 20013997 22. Knob (two per fireplace) 1600657 [...]

  • Page 21

    21 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 The following accessories for this appliance are available from your local Monessen distributor . Should you need ad- ditional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY 40361, Attn: T echnical Services. CAUTION: This fireplace and c[...]

  • Page 22

    22 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Chimney Components Component Description Model Number Chimney Support Used to support chimney for each of TCS8A 30’ vertical height and 6’ of angled chimney run (8” flue) Firestop Required at each floor level and attic on FS2A (8” straight flue) multi-story installation FS6A (8” [...]

  • Page 23

    23 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 LIMITED W ARRANTY Factory-Build Fireplace and Components (Except Blowers) What is Covered and For How Long Five-Y ear Coverage: For five years from the date this fireplace and components are first purchased for use, MHSC will, at its option, repair or replace any defective part of this fir[...]

  • Page 24

    MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com[...]