Go to page of
Similar user manuals
-
Indoor Fireplace
Monessen Hearth DFS36C
1 pages 0.45 mb -
Indoor Fireplace
Monessen Hearth DFS36NVC
44 pages 6.24 mb -
Indoor Fireplace
Monessen Hearth CWC500
24 pages 1.58 mb -
Indoor Fireplace
Monessen Hearth SWB400I
40 pages 1.48 mb -
Indoor Fireplace
Monessen Hearth Direct Vent BDV400C
1 pages 0.53 mb -
Indoor Fireplace
Monessen Hearth BWBC400MHB
40 pages 2.18 mb -
Indoor Fireplace
Monessen Hearth DFS36PVC
44 pages 6.24 mb -
Indoor Fireplace
Monessen Hearth HDV500NV/PV
64 pages 6.78 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Monessen Hearth MJ27PR, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Monessen Hearth MJ27PR one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Monessen Hearth MJ27PR. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Monessen Hearth MJ27PR should contain:
- informations concerning technical data of Monessen Hearth MJ27PR
- name of the manufacturer and a year of construction of the Monessen Hearth MJ27PR item
- rules of operation, control and maintenance of the Monessen Hearth MJ27PR item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Monessen Hearth MJ27PR alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Monessen Hearth MJ27PR, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Monessen Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Monessen Hearth MJ27PR.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Monessen Hearth MJ27PR item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
860024 MJ27 cov er 10/08 READ AND SA VE THESE INSTRUCTIONS Unvented Gas Log Heater or V ented Decorative Appliance Installation and Operating Instructions It uses air (oxygen) from the room ?[...]
-
Page 2
2 86D0024 CONTENTS Important Safety Information 3 Getting Started ?[...]
-
Page 3
86D0024 3 9. The installation must conform with local codes or , in the absence of local codes, with the National Fuel 10. This unit complies with the latest revision of AN[...]
-
Page 4
4 86D0024 continued from page 3 15. This is an unvented gas-red heater . It uses air (oxygen) from the room in which it is installed. Pro - visions for adequate combustion and ventilation air must be provided. See page 8. 16. Keep room area clear and free fro[...]
-
Page 5
86D0024 5 Check your packing list to verify that all listed parts have been received. Y ou should have the following: • Unvented Gas Log Burner Assembly • T wo (2) Plastic Bags Containing Crushed V olcanic Rock • Installation[...]
-
Page 6
6 86D0024 and NA TURAL GAS NOTE: An external regulator is required to reduce supply pressure to a maxi- mum of 10 1 / 2 " W .C. on natural gas systems operating at higher pressure. MILLIVOL T Regulator Pressure Setting: 3.5" w .c. Pilot Regula[...]
-
Page 7
86D0024 7 GENERAL INST ALLA TION INFORMA TION CODES Adhere to all local codes or , in their absence, the latest edition of THE NA TIONAL FUEL GAS CODE ANSI Z223.1 or NFP A54 which can be obtained from… 1430 Broadway Ne[...]
-
Page 8
8 86D0024 FP2000 log clearances W H The following formula can be used to determine the maximum heater rating per the denition of unconned space: BTU / hr = (L1 + L2) Ft x (W) Ft x (H) Ft. x 1000 BTU / hr 50 Consider two connecting rooms with an open area between, with the following dimensions: L 1 = 15 1 / 2 Ft., L 2 = 12 Ft., W = 12 Ft., H =[...]
-
Page 9
86D0024 9 19” 27” 14” 30” FP1994 Min. hearth dims and HEARTH DIMENSIONS ?[...]
-
Page 10
10 86D0024 X FP1995 logset in enclosure ?[...]
-
Page 11
86D0024 1 1 16" 42" FP1996 wall ceiling clearanc es FP1996 CLEARANCES and HEIGHT REQUIREMENTS Sidewall and ceiling clearances: The sides of the replace opening must be at least 16" from any combustible wall. The ceiling must be at least 42" from the top of the replace opening. Figure 4 - Sidewall and Ceiling Clearances Th [...]
-
Page 12
12 86D0024 FP1997 heat resistant ma terial Heat Resistant Material Heater in Fireplace or Firebox FP1997 Measure This Distance Figure 5 - Measuring Heat Resistant Material Heat resistant material (minimum requirements) with no wooden mantel or other combustible projection: T o install the gas logs into a replace with no wooden mantel, shelf or o[...]
-
Page 13
86D0024 13 FP1998 heat resist mant el Hood Heater in Fireplace or Firebox 8" or More of Heat Resis- tant Materials FP1998 CLEARANCES and HEIGHT REQUIREMENTS Figure 6 - Measuring Heat Resistant Material for Mantel Heat resistant material (minimum requirements) with wooden mantel or other combustible projection: T o install the heater with a woo[...]
-
Page 14
14 86D0024 CLEARANCES and HEIGHT REQUIREMENTS Figure 7 - Minimum Mantel Clearance with Hood - All Models Example: A mantel may project from the wall a maxi- mum of 2 1 / 2 " at a minimum of 8" above the opening, and a maximum of 6" at a minimum of 14 1 / 2 " above the opening. 10" 12" 8" 6" 2 1 /2 " 8&qu[...]
-
Page 15
86D0024 15 FP2002 mantel clearanc es unsafe 2 1 / 2 " 8" 6" 7" 14 1 / 2 " 4" Mantel Minimum of 8" Heat Resistant Material Hood FP2002 Figure 9 - Minimum Mantel Clearance with Hood - MJ27 (Example of Unsafe Installation) CLEARANCES and HEIGHT REQUIREMENTS Figure 9 is an example of an unsafe mantel instal- lation. T[...]
-
Page 16
16 86D0024 14" Minimum FP2004 min clear nocomb floor Heater in Fireplace or Firebox Combustible Material This Distance May Now be Less Than 1 3 / 8 " FP2004 FLOOR CLEARANCE The gas log heater must be installed at least 1 3 / 8 " above any combustible ooring material, such as carpeting or tile, which is closer than 14" to the [...]
-
Page 17
86D0024 17 FP2005 damper install Damper Stop Damper FP2005 • T urn of f gas supply to replace or rebox. • Have the repla ce oor and chimney professi onally cleane d to remove ashes, soot, creosote or other obstru c - tions. Have this cl[...]
-
Page 18
18 86D0024 FP2006 secure to floor 1. Center the gas log unit on the replace or rebox. Make certain[...]
-
Page 19
86D0024 19 FP2007 gas connection FP2007 Pipe Coupling T o Heater V alve Gas Supply Inlet CONNECTING THE GAS NOTICE: A qualied gas appliance installer must connect the heater to the gas supply . Consult all local codes. IMPORT ANT : Hold heater valve rmly with a wrench to prevent movement when connecting to inlet pipe. Manual Shutoff V alve Pi[...]
-
Page 20
20 86D0024 FP2008 gas valve FP2008 The heater gas inlet connection is a 3/8" NPT at the valve. On all control type units, the inlet connection is on the right side of unit. T o connect from the opposite side, route the pipe around the back portion of the unit. When tightening up t[...]
-
Page 21
86D0024 21 FP2009 MJ wiring diagram FP2009 Motor ELECTRICAL WIRING (MILLIVOL T) The Millivolt valve is a self-powered combination gas control - Figure 16 - Wiring Diagram CAUTION ?[...]
-
Page 22
22 86D0024 ELECTRICAL WIRING (MILLIVOL T) CONNECTING REMOTE RECEIVER 1. Set remote receiver . See instructions included in receiver kit. 2. Connect the two (2) 1/4" female connectors to the TP/TH and TH terminals on the control valve. 3. C o n n e c t t h e f o u r - p i n connector from the valve mot or to the four -pi n con- nector on the re[...]
-
Page 23
86D0024 23 Before installing logs, place rock- wool i n dim e size p iec es eve nly over small burner ports starting in front of the rear deector shield towards the front. Avoid placing rock wool over th e s lots on rear and right side of burner and on large yellow ame ports on front of burner [...]
-
Page 24
24 86D0024 L G553 MJ127 log 8 10/08 Log #8 LG553 Figure 20 - Install Log #8 1. Place log #8 on right bracket next to valve by sliding grooves on sides of log into cutout on brackets. Figure 20 L G554 MJ127 log 1 10/08 Log #1 LG554 Figure 21 - Install Log #1 2. Pl ace log #1 by sett ing the log ov er the rear [...]
-
Page 25
86D0024 25 L G546 MLDV log #4 Log #4 LG546 Figure 24 - Install Log #4 5. Place Log #4 by matching the rect- angular protrusion on the bottom of thi s log over the rec tang ula r not ch on log #3. Swing the log slightly to the front and set the log over the notch located on the upper surface of log #3. Figure [...]
-
Page 26
26 86D0024 Place ickering bright embers (FBE-1G) after placing logs on burner . Pull apart into small strands and place on top of existing rock wool in front of and between front logs where they can be seen. T ry to avoid stacking these embers on top of each other . Use smalle[...]
-
Page 27
86D0024 27 ANDIRON and ROCK INST ALLA TION ANDIRON INST ALLA TION 2, Andirons 2, Brackets 2, 2 1 / 4 Bolts Assembly Instructions 1. Afx bracket to andiron using 2 1 / 4 bolts. Figure 29 2. The andiron bracket clips over the lower horizontal grate bar . Figure 30 3. The left andiron goes to the left of the large knot on the front left log. The ri[...]
-
Page 28
28 86D0024 FP2015 pilot flame wrong Figure 31 - Correct Appearance of Pilot Flame Figure 32 - Incorrect Appearance of Pilot Flame Thermocouple for LP Thermocouple for Natural Flames from the pilot and burner should be visually checked as soon as the heater In [...]
-
Page 29
86D0024 29 L G551 MJ log flames LG551 should be observed: Figure 33 - Correct Burner Flame [...]
-
Page 30
30 86D0024 This appliance is equipped with a piezo ignition device which lights the pilot. If piezo is not working properly see Match Lighting Instructions, Page 32. BEFORE OPERA TING smell all around the appliance area for gas. Be sure to smell next to the oor because some gas is heavier than air and will settle on the oo[...]
-
Page 31
86D0024 31 FP2017 pilot 1. Read the safety information label. 2. Make sure the manual shutoff valve is fully open. 3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo ignitor does not light the pilot, refer [...]
-
Page 32
32 86D0024 / CLEANING and SER VICING CLEANING AND SER VICING ?[...]
-
Page 33
86D0024 33 Note: All troubleshooting items are listed in order of operation. TROUBLESHOOTING W ARNING REMEDY When ignitor button is pressed, there is no spark at ODS/pilot. 1. Ignitor electrode positioned wrong. 1 Replace ignitor . 2. Ignitor electrode is b[...]
-
Page 34
34 86D0024 TROUBLESHOOTING If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and [...]
-
Page 35
86D0024 35 1 2 3 4 5 6 7 8 0024 MJ parts 1. Burner 1 86D0017 86D0018 2. Control V alve 1 20H2081 20H2082 3. ODS Pilot Assembly 1 14D0473 14D0473 4. Piezo Igniter 1 14D0503 14D0503 5. Piezo[...]
-
Page 36
36 86D0024 8 1. Log #1 1 75D0536 2. Log #2 1 75D0537 3. Log #3 1 75D0538 4. Log #4 1 75D0539 5. Log #5 1 75D0540 6. Log #6 1 75D0541 7. Log #7 1 75D0542 8. Log #8 1 86D0019 LOGS REPLACEMENT P ARTS[...]
-
Page 37
86D0024 37 NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas tter when installed within the Commonwealth of Massachu - setts. Any residence with a direct vent product must have a CO detector installed in the residence. Installation of the replace or vented gas log in the State of Massachusetts requires[...]
-
Page 38
38 86D0024 NOTES[...]
-
Page 39
LIFETIME W ARRANTY The following components are warranted for life to the original owner , subject of proof of purchase: Firebox, Combustion Chamber , Heat Exchanger , Grate, and Stainless Steel Burners. FIVE YEAR W ARRANTY The following components ar[...]
-
Page 40
OCTOBER 2008 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com[...]