Monessen Hearth SBV500 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Monessen Hearth SBV500, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Monessen Hearth SBV500 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Monessen Hearth SBV500. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Monessen Hearth SBV500 should contain:
- informations concerning technical data of Monessen Hearth SBV500
- name of the manufacturer and a year of construction of the Monessen Hearth SBV500 item
- rules of operation, control and maintenance of the Monessen Hearth SBV500 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Monessen Hearth SBV500 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Monessen Hearth SBV500, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Monessen Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Monessen Hearth SBV500.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Monessen Hearth SBV500 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    B-V ent Series Natural V ent Gas Fireplace Installation & Operating Instructions W ARNING IF THE INFORMA TION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PER- SONAL INJUR Y OR LOSS OF LIFE. — Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of t[...]

  • Page 2

    62D4036 2 BB V , SB V Se ries N atur al V ent Gas F ireplaces T ABLE OF CONTENTS Thank you and congratulations on your purchase of an MHSC Fireplace Please read the Installation and Operation Instructions before using the appliance! IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instr[...]

  • Page 3

    62D4036 3 BB V , SB V Se ries N atur al V ent Gas F ireplaces IMPORT ANT SAFETY INFORMA TION INST ALLER Please leave these instructions with the appliance. OWNER Please retain these instructions for future reference. This fireplace is a decorative gas appliance. This fire- place must be properly installed by a qualified service person. CARBON MONOX[...]

  • Page 4

    62D4036 4 BB V , SB V Se ries N atur al V ent Gas F ireplaces CODE APPROV AL These appliances have been tested by CSA and found to comply with the established standards for VENTED GAS FIREP ACES in the US and Canada as follows: LISTED VENTED GAS FIREPLACE TESTED T O: ANSI Z21.50a-2008 CSA2.22a-2008 14. Do not use any solid fuels (wood, coal, paper [...]

  • Page 5

    62D4036 5 BB V , SB V Se ries N atur al V ent Gas F ireplaces PRODUCT FEA TURES PRODUCT SPECIFICA TIONS • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. • The appliance must be installed in accordance with local codes if any . If none[...]

  • Page 6

    62D4036 6 BB V , SB V Se ries N atur al V ent Gas F ireplaces FIREPLACE DIMENSIONS & FRAMING Do not fill spaces around firebox with insulation or other materials. This could cause a fire. W ARNING 31 6 ” (797 mm) 8” (203 mm) 14” (356 mm) 14 56O ” (368 mm) Min. Rough Opening Depth 40 56O ” (1029 mm) Min. Rough Opening Width 4” [...]

  • Page 7

    62D4036 7 BB V , SB V Se ries N atur al V ent Gas F ireplaces FIREPLACE DIMENSIONS & FRAMING 21” (533 mm) 21 56O ” (546 mm) Min. Rough Opening Depth 4” B-V ent 1/2” or 5/8” Drywall Spacers 40" (1016 mm) 34” (864 mm) 21 56O ” (546 mm) B A 40 56O ” (1029 mm) Min. Rough Opening Height 1/2" or 5/8" Drywall Spacers 16 [...]

  • Page 8

    62D4036 8 BB V , SB V Se ries N atur al V ent Gas F ireplaces FP2406 BBV 400 clearances PRE-INST ALLA TION INFORMA TION FIREPLACE LOCA TION Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional acces- sories[...]

  • Page 9

    62D4036 9 BB V , SB V Se ries N atur al V ent Gas F ireplaces SECURE FIREPLACE TO FLOOR OR FRAMING The fireplace must be secured to the floor and/or to framing studs as shown in Figure 5 . Use two (2) wood screws or masonry/con- crete screws to secure fireplace to the floor . Use four (4) screws to attach fireplace to framing. The side brackets are[...]

  • Page 10

    62D4036 10 BB V , SB V Se ries N atur al V ent Gas F ireplaces VENT INST ALLA TION INST ALLA TION PLANNING “B” VENT PIPE See venting installation instructions provided by the B- V ent manufacturer . NOTE: This APPLIANCE MUST BE INST ALLED using “B” vent type pipe that has been listed by a nationally rec- ognized testing agency . Refer to B-[...]

  • Page 11

    62D4036 1 1 BB V , SB V Se ries N atur al V ent Gas F ireplaces VENT INST ALLA TION FIRESTOPS • Locate chimney centerline dimension from a com- bustible back wall. Figures 2 & 3. Minimum firestop dimensions are found in the vent manufacturer ’s in- structions. Clearances to combustibles may also be found on the sides of the flue sections. ?[...]

  • Page 12

    62D4036 12 BB V , SB V Se ries N atur al V ent Gas F ireplaces OUTSIDE COMBUSTION AIR NOTE: The use of outside air for combus- tion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of fireplace. Use model OAC4 combustion air kit (refer to Page 17). 1. A void extremely long runs and num[...]

  • Page 13

    62D4036 13 BB V , SB V Se ries N atur al V ent Gas F ireplaces COMBUSTION AIR ASSEMBL Y MODEL OAC-4 COMBUSTION AIR ASSEM- BL Y 1. Remove the cover plate from the 4” outlet opening location on the left outside of the fireplace. 2. Place starting collar (4”) into hole on left side of fire- place. Fireplace shortest side of air starting collar thr[...]

  • Page 14

    62D4036 14 BB V , SB V Se ries N atur al V ent Gas F ireplaces FIREPLACE INST ALLA TION CHECK GAS TYPE Use proper gas type for the fireplace you are installing. If you have conflicting gas types, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type. INST ALLING GAS PIPING TO FIREPLACE LOCA TI[...]

  • Page 15

    62D4036 15 BB V , SB V Se ries N atur al V ent Gas F ireplaces FIREPLACE INST ALLA TION W ARNING Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. CAUTION A manual shut-off valve must be installed upstream of the appliance. Union tee and plugged 1/8” NPT pressure tapping point should be instal[...]

  • Page 16

    62D4036 16 BB V , SB V Se ries N atur al V ent Gas F ireplaces CHECKING GAS PRESSURE 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately . 2. T o ease installation, a 30” (762 mm) flex [...]

  • Page 17

    62D4036 17 BB V , SB V Se ries N atur al V ent Gas F ireplaces ELECTRICAL INST ALLA TION V erify proper operation after servicing. REMOTE W ALL MOUNTED SWITCH A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 16. Do no[...]

  • Page 18

    62D4036 18 BB V , SB V Se ries N atur al V ent Gas F ireplaces ELECTRICAL INST ALLA TION ELECTRONIC PILOT IGNITION WIRING W ARNING Do not connect 1 10-120V AC to the Re- mote W all Switch. The appliance will malfunction or destroyed. &0 ELECTRONICIGNITIONWIRING  Figure 17 - Electronic Ignition System Wiring Diag[...]

  • Page 19

    62D4036 19 BB V , SB V Se ries N atur al V ent Gas F ireplaces L G662 BBV SBV400 logs FINAL INST ALLA TION ROCK WOOL PLACEMENT 1. Place rock wool on burner to provide glowing embers. For best results, pull the rock wool apart into pieces the size of a nickel or dime. 2. Distribute one layer of rock wool to cover the entire burner . Figure 18 3. Pla[...]

  • Page 20

    62D4036 20 BB V , SB V Se ries N atur al V ent Gas F ireplaces OPERA TING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal in- jury or loss of life. A. This appliance is equipped with a pilot which must be lit w ith an ignito[...]

  • Page 21

    62D4036 21 BB V , SB V Se ries N atur al V ent Gas F ireplaces OPERA TING INSTRUCTIONS LIGHTING PILOT FOR THE FIRST TIME LIGHTING PILOT W ARNING The control has an interlock device that does not allow the lighting of the fireplace up to the moment the safety device of the flame has not interrupted the gas flow. After that pe- riod of time (when the[...]

  • Page 22

    62D4036 22 BB V , SB V Se ries N atur al V ent Gas F ireplaces OPERA TING INSTRUCTIONS LIGHTING BURNER LIGHTING PILOT T O L I P O F F P I L O T O N &0 CONTROLKNOBPILOT Figure 23 - Pilot Position MAIN BURNER SWITCH The “ON/OFF” switch for the main burner can be found behind the door of the fireplace. This switch allows you [...]

  • Page 23

    62D4036 23 BB V , SB V Se ries N atur al V ent Gas F ireplaces OPERA TING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal in- jury or loss of life. A. This appliance is equipped with an ignition device (Piezo) which automati[...]

  • Page 24

    62D4036 24 BB V , SB V Se ries N atur al V ent Gas F ireplaces L G663 BBV SBV400 log flame LG663 CLEANING and MAINTENANCE W ARNING T urn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. BURNER, PILOT AND CONTROL COMP ARTMENT Keep the control co[...]

  • Page 25

    62D4036 25 BB V , SB V Se ries N atur al V ent Gas F ireplaces CLEANING and MAINTENANCE VENT SYSTEM The fireplace and venting system should be inspected before initial use and at least annually by a quali- fied field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow . Inspec[...]

  • Page 26

    62D4036 26 BB V , SB V Se ries N atur al V ent Gas F ireplaces REPLACEMENT P ARTS FIREBOX COMPONENTS 4a 4b 4c  ""63"6FIREBOXPARTS 1 2 3 5 6 7[...]

  • Page 27

    62D4036 27 BB V , SB V Se ries N atur al V ent Gas F ireplaces REPLACEMENT P ARTS FIREBOX COMPONENTS Item Description Qty . BBV400 SBV400 SBV500 1. Pull Screen Panel 2 61D0001 61D0001 61D0003 2. Refractory Side 2 n/a 61D0101 61D0101 3. Refractory Back 1 n/a 61D0102 61D0102 4a. Left Refractory 1 n/a 62D1015 62D2015 4b. Middle Refractory 1 n/a 62D101[...]

  • Page 28

    62D4036 28 BB V , SB V Se ries N atur al V ent Gas F ireplaces REPLACEMENT P ARTS ST ANDING PILOT - MILLIVOL T CONTROL 1 2 3 4 5 6 7 8 10 12, 13 2T 2 I 2C 9 1 1  ""63"6CONTRPARTS[...]

  • Page 29

    62D4036 29 BB V , SB V Se ries N atur al V ent Gas F ireplaces REPLACEMENT P ARTS ST ANDING PILOT - MILLIVOL T CONTROL Item Description Qty . BBV400NV BBV400PV SBV400NV SBV400PV SBV500NV SBV500PV 1. Gas V alve Assembly 1 37D01 17 37D01 18 37D01 17 37D01 18 37D01 17 37D01 18 2. Pilot Assembly 1 37D0018 37D0019 37D0018 37D0019 37D0018 37D0019 2C. Rep[...]

  • Page 30

    62D4036 30 BB V , SB V Se ries N atur al V ent Gas F ireplaces REPLACEMENT P ARTS ELECTRONIC IGNITION 1 2 3 4 5 6 7 9 8 10 1 1 12  ""63"6ELECTRONICIGNITIONPAR TS[...]

  • Page 31

    62D4036 31 BB V , SB V Se ries N atur al V ent Gas F ireplaces REPLACEMENT P ARTS ELECTRONIC IGNITION Item Description Qty . BBV400NV BBV400PV SBV400NV SBV400PV SBV500NV SBV500PV 1. Gas V alve Assembly 1 37D0016 37D0017 37D0016 37D0017 37D0016 37D0017 2. Pilot Assembly 1 37D0020 37D0021 37D0020 37D0021 37D0020 37D0021 3. Burner T ube 1 62D4051 62D4[...]

  • Page 32

    62D4036 32 BB V , SB V Se ries N atur al V ent Gas F ireplaces TROUBLESHOOTING ST ANDING PILOT IGNITION SYMPTOM 1. Spark igniter will not light pi- lot after repeat- ed triggering of piezo. 2. Pilot will not stay lit after carefully fol- lowing lighting instructions. 3. Pilot burning, valve knob tuned to “ON”, switch is turned to “ON” or ?[...]

  • Page 33

    62D4036 33 BB V , SB V Se ries N atur al V ent Gas F ireplaces TROUBLESHOOTING ELECTRONIC IGNITION ST ART 1. Turn gas supply of f. 2. Turn ON/OFF switch to “ON” Power to module (24V Normal) YES Is there a spark across ignitor sensor gap? YES T urn on gas. Does pilot burner light? YES Does spark stop when pilot is lit? YES Does main burner light[...]

  • Page 34

    62D4036 34 BB V , SB V Se ries N atur al V ent Gas F ireplaces TROUBLESHOOTING GENERAL TROUBLESHOOTING SYMPTOM 1. Glass soots. 2. Poor draft due to venting. 3. Poor draft due to termination cap. 4. Poor draft due to ext. environ- ment. 5. Poor draft due to internal envi- ronment. 6. Unit shuts down prematurely . POSSIBLE CAUSE A. Flame impingement [...]

  • Page 35

    62D4036 35 BB V , SB V Se ries N atur al V ent Gas F ireplaces[...]

  • Page 36

    62D4036 36 BB V , SB V Se ries N atur al V ent Gas F ireplaces[...]

  • Page 37

    62D4036 37 BB V , SB V Se ries N atur al V ent Gas F ireplaces[...]

  • Page 38

    62D4036 38 BB V , SB V Se ries N atur al V ent Gas F ireplaces NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Any residence with a direct vent product must have a CO detector installed in the residence. Installation of the fireplace or vented[...]

  • Page 39

    62D4036 39 BB V , SB V Se ries N atur al V ent Gas F ireplaces LIMITED LIFETIME W ARRANTY POLICY LIFETIME W ARRANTY The following components are warranted for life to the original owner , subject to proof of purchase; Firebox, Combus- tion Chamber , Heat Exchanger , Grate and Stainless Steel Burners. FIVE YEAR W ARRANTY The following components are[...]

  • Page 40

    MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com[...]