1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Moxa AWK-4131-M12-EU-T, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Moxa AWK-4131-M12-EU-T one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Moxa AWK-4131-M12-EU-T. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Moxa AWK-4131-M12-EU-T should contain:
- informations concerning technical data of Moxa AWK-4131-M12-EU-T
- name of the manufacturer and a year of construction of the Moxa AWK-4131-M12-EU-T item
- rules of operation, control and maintenance of the Moxa AWK-4131-M12-EU-T item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Moxa AWK-4131-M12-EU-T alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Moxa AWK-4131-M12-EU-T, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Moxa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Moxa AWK-4131-M12-EU-T.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Moxa AWK-4131-M12-EU-T item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

     2010 Moxa Inc . A ll righ ts reserved. Reprodu ction w ithout perm ission i s prohib ited. P/N: 1 8020 4131001 0 AWK- 4131 Hardware Installation G uide Moxa Air Works First E dition, M arch 20 11[...]

  • Page 2

    - 2 - Notes f or the Re ader WARNI NG I ndicates that death or personal injury may occur if proper precautions are not taken. ATTENTION I ndicates that possible damage to this product or your property may result if proper precautions a re not taken. NOTE H ighlights important information related to th is pr oduct. Package Checkl ist Moxa’s AW K -[...]

  • Page 3

    - 3 - • SFP - 1G LXLC - T: Small form factor pluggable transc eiver with 1000BaseLX, LC, 10 k m, - 40 to 85°C • SFP - 1G LHLC: Small form factor p luggable transceiver with 1000BaseLH, LC, 30 km, 0 to 60°C • SFP - 1G LHLC - T: Sma l l fo rm factor pluggable transceiver with 1000BaseLH, LC, 30 km, - 40 to 85°C • SFP - 1G LHXLC : Small for[...]

  • Page 4

    - 4 - NOTE To make the change effective, you must save the change an d then click Restar t  Save and R estar t button t o apply all change s. Panel Layout of the AW K - 4131 1. Main antenna A . 2. Main antenna B . 3. LEDs for PW R, FA ULT, STATE, WLAN an d LAN . 4. M12 A - codin g conne ctor for PW R1 an d P WR2 . 5. M12 8 - p in ma le connect o[...]

  • Page 5

    - 5 - Dimensi ons (un it = mm ) Attachi ng Ante nna s The AWK - 4131 in clu es t wo d ua l - band omn i - directional antenna by default. Attach the antennas as illustrated below. Step 1 : Use your fingers and hold the antenna metal N - type c onnec tor. Step 2: Scre w the antenna N - type con nector (male) onto the AWK - 4 131 device’ s N - ty p[...]

  • Page 6

    - 6 - STEP 1: Attach the wall - mounting kit with M4 screws, as shown in the d iagram bel ow. STEP 2: Mounting the AWK - 4131 on the wall require s 4 s crews. Use th e AW K - 4131 de vice , wit h wa ll - mounting kit attached, as a guide to mark the correct locat ions of th e 4 screw s. Th e heads of the scr ews are recomm ended to be between 5 .5m[...]

  • Page 7

    - 7 - DIN - Ra il Mountin g (Opt ional) The DK - DC50131 die - cast meta l kit can be bought separately, and enable easy and robust installation for the AWK - 41 31 . A pa ir of DK - DC50131s is needed for DIN - Rai l mounting. To install the DIN - Rail mo unting kits, tightly attach the two DI N - Rail mounting kits on the rear panel of AWK - 4131[...]

  • Page 8

    - 8 - Wiri ng Requi rement s WARNI NG Safety Fir st! Be sure to di sconnec t the power cord bef ore installi ng and/o r wirin g your Mo xa A WK - 4131 . Calculate the maximum possib le current in each power wire and common wire. Obser ve al l elect rical codes dictat ing the maxim um current allowabl e for each wi re si ze. If the c urrent g oes ab[...]

  • Page 9

    - 9 - ATTENTION This pro duct is intende d to be supplied by a Listed Power Unit marked “Class 2” or “ LPS” and rated O /P: 12 to 48 VDC , minimum 6 W (12 V/0.494 A to 48V/0.121 A , 25°C). Make sure External Power Adaptor ( includes power cords and plug asse mblies) provide d with t he u nit is ce rt if ied a nd su ita b le for use in your[...]

  • Page 10

    - 10 - Communi cati on Connec tions Connec ting t he Data L ines 10/10 0/ 1000 Base T(X) Eth er net Por t Con nec tion AWK - 4131 ha s 10/100/1000 Ba seT(X) Ethernet po rts ( 8-p in sh ie ld e d M 12 connect or with A c od ing ). The 10/100 /1000 BaseT(X) p orts located on the AWK - 41 3 1’ s bott om pa ne l are used to connect to Ethernet - enab[...]

  • Page 11

    - 11 - Install atio n 1. Refer to the pin ass ignment and solder wires with  ; 2. Then assemb le  ,  ,  , an d  in order; 3. Test the plug to ensure the quality. RS - 23 2 Con ne ction The AWK - 4131 has one R S- 232 (8 - pin RJ45 ) console por t located on the bottom panel. Use either an RJ45 - to - DB9 or RJ4 5 - to - DB25 cable to[...]

  • Page 12

    - 12 - LED Color State Description Bl ink in g (fast ) IP addr ess c onflict (int erval: 0.5 s ec) Off Error con dit ion does n ot ex ist. STATE Green/Red Green Software Ready Green , b lin k ing The AWK has been located by AWK Se ar ch U ti lit y. ( int er va l: 1se c ) Red Booting or Error con dition WLAN Green/ Amber Green , on WLA N fun ct ion [...]

  • Page 13

    - 13 - 5.18 to 5.24 GHz (4 c hannels for W52) Se cu rity : • SSID broa dcas t ena ble /disa ble • Firewa ll for MAC /IP/Prot ocol/P ort - ba se d f ilt er in g • 64 - bit and 128 - b it WEP encr ypti on, WPA/WP A2 - Perso nal and Enterprise (IEEE 802.1X/RADIU S, TKIP and AES) Transmission Rates: 802.11b: 1, 2, 5.5, 11 M bps 802.11a/g: 6, 9, 1[...]

  • Page 14

    - 14 - LAN Por ts: 1, 10/100/1000BaseT(X), aut o negotiation speed (M12 female type) Fiber Ports: 1, 1000BaseSFP slot Console P ort: RS - 232 (waterpro of RJ45 - type ) LED In dicator s: PWR, FAULT, STATE, WLAN, LAN Alarm Contact (digital output, M 12 ma le connect or): 1 relay output with current carrying capacity of 1 A @ 24 V DC Digital Inputs ([...]