A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Murphy Automatic Engine Controller A88, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Murphy Automatic Engine Controller A88 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Murphy Automatic Engine Controller A88. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Murphy Automatic Engine Controller A88 should contain:
- informations concerning technical data of Murphy Automatic Engine Controller A88
- name of the manufacturer and a year of construction of the Murphy Automatic Engine Controller A88 item
- rules of operation, control and maintenance of the Murphy Automatic Engine Controller A88 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Murphy Automatic Engine Controller A88 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Murphy Automatic Engine Controller A88, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Murphy service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Murphy Automatic Engine Controller A88.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Murphy Automatic Engine Controller A88 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
AUTOMA TIC ENGINE CONTROLLERS MODELS A88 AND A88-F INST ALLA TION MANUAL A88-8916N Revised 01-97 Section 40 (00-02-0196) ®[...]
-
Page 2
T ABLE OF CONTENTS SECTION P AGE I INTRODUCTION 1 II SPECIFICA TIONS 1 IIA Power Requirements 1 IIB Input Requirements 1 IIC Output Ratings 1 III FRONT P ANEL DESCRIPTION 2 IIIA Description of LED Callouts 3 IIIB Description of AOT Switch, Crank Disconnect Control & Rest/Crank T ime Control 3 IV OPTIONAL HOOKUPS 4 V OPERA TION 5 LIST OF ILLUSTR[...]
-
Page 3
WARNING BEFORE BEGINNING INST ALLA TION OF THIS MURPHY PRODUCT ✔ Disconnect all electrical power to the machine. ✔ Make sure the machine cannot operate during installation. ✔ Follow all safety warnings of the machine manufacturer . ✔ Read and follow all installation instructions.[...]
-
Page 4
A. The Automatic Engine Controller , Model A88 and A88-F is designed to automatically start, monitor and stop electric start engines. The A88 comes in an all-weather case with a 5 foot cable and a plug for connection. The A88-F is the same system, but housed in a panel-mount case with terminals on back for connecting. B. Features 1. Has a self-cont[...]
-
Page 5
SECTION III: FRONT P ANEL DESCRIPTION 20s 15s 10s 5s CRANK AND REST TIME PICK UP PRESENT CRANK CRANK DISCONNECT IGNITION ON CRANK DISCONNECT OVER CRANK ENGINE TEMP. CHOKE OIL PRESSURE AUTO OFF TEST CRANK AND REST TIME IGNITION ON PICK UP PRESENT CRANK CRANK DISCONNECT CRANK DISCONNECT 20s 15s 10s 5s CHOKE OVER CRANK OIL PRESSURE ENGINE TEMP. AUTO O[...]
-
Page 6
FRONT P ANEL DESCRIPTION Along with each description, an attempt has been made to clarify output and input connections according to their functions and terminals or wire color . A. Description of LED Callouts 1. IGNITION The ignition LED will come on when the system receives a signal to start. If the alarm before start is used, this ignition LED wi[...]
-
Page 7
In this section the terms Sink and Source are used. Sink: This terms refers to an output that switches to ground to do work. Source: This term will be used to refer to an output that is switched to positive to do work. 1. CHOKE T o use this feature, connect the choke or compression release solenoid to the battery positive and then to the terminal o[...]
-
Page 8
Refer to Diagrams 1 and 3: Basic Wiring Hookup for correct connections to your engine. Diagram 2 shows wire colors that correspond to the A88 plug and hookup wire, in the event of two colors the first color is the primary color and the other is a tracer color . Diagram 4 identifies the A88-F wiring terminals. Step No. 1, Pickup: Determine the type [...]
-
Page 9
123 Grey Blue White/Black Green White/Red White/Brown Yellow Brown Green/White Brown/White Grey/White Red/White White White/Orange White/Yellow Violet/White Orange Red/White ground for 5 seconds Alarm On Start Connect SPST For Momentary Type Operation Close to Run Open to Stop Ignition Connection Breaker Type, 6 amp max Ignition Connection CDI Type[...]
-
Page 10
7 Pin 1-wire-Wht/Blk: Breaker ignition I/P Pin 2-wire-Green: Vacuum switch I/P Pin 3-wire-Viol/Wht: Grnd for time delay I/P Pin 4-wire-Grey: Magnetic pickup I/P Pin 5-wire-Blue: Tach alternator I/P Pin 6-wire-Violet: Choke (sink) O/P Pin 7-wire-Wht/Red: Crank (sink) O/P Pin 8-wire-Yellow: Engine running (sink) O/P Pin 9-wire-Grn/Wht: Start I/P Pin [...]
-
Page 11
8 123 6 7 5 8 2 1 18 20 4 17 16 15 23 21 22 9 19 Ground for 5 seconds Alarm On Start Connect SPST For Momentary T ype Operation Close to Run Open to Stop Ignition Connection Breaker T ype, 6 amp max Ignition Connection CDI T ype 6 amp max Ground to Kill Stop 16 No Connection Ground for 5 seconds Alarm On Start V acuum Switch Solenoid Switched to Gr[...]
-
Page 12
Terminal 1: Crank (source) Diagram 4: A88-F Wiring Terminals Terminal 2: Crank (sink) Terminal 3: Choke (sink) Terminal 4: Start I/P Terminal 5: Breaker ignition I/P Terminal 6: Magnetic pickup I/P Terminal 21: Common Terminal 22: Normally Closed (N.C.) Terminal 23: Normally Open (N.O.) Terminal 24: No Connection Terminal 25: Negative (–) Termina[...]
-
Page 13
Fuel V alve Start Float Switch 100 1/2 W Ignition N.O. Battery Pos. Ground Pickup Oil Level Switch Crank Diagram 5: A88/A88-F Wiring for Honda Generator Green Y ellow Ground for Alarm Before Start IN4005 Oil Press. Shutdown Grey/White Brown/White Stop White/Y ellow White/Brown Black Blue Red Black/White White Red/White Ignition N.C. Green/White A88[...]
-
Page 14
100 1/2 W Diagram 6: A88/A88-F Wiring for Honda Generator White Black Blue Red 18 ga White/Brown Grey/White Red/White Red/White A88 White/Orange 23 25 7 26 1 16 11 4 12 15 21 or A88-F E IG BA T LO ST Combination Switch Brown/White Grey/White Red/White 17 T o Y ellow/Red (OIL) T o Y ellow/Grn (TEMP) Closed to Start Open to Stop Connect Black/Red Whi[...]