Go to page of
Similar user manuals
-
Indoor Fireplace
Napoleon Fireplaces GDI-30P
16 pages 0.71 mb -
Indoor Fireplace
Napoleon Fireplaces BGD36PTR
32 pages 1.14 mb -
Indoor Fireplace
Napoleon Fireplaces EPA1400
20 pages 1.08 mb -
Indoor Fireplace
Napoleon Fireplaces GD82PT
34 pages 7.27 mb -
Indoor Fireplace
Napoleon Fireplaces BGNV36N
20 pages 5.03 mb -
Indoor Fireplace
Napoleon Fireplaces ZCVF42
12 pages 0.65 mb -
Indoor Fireplace
Napoleon Fireplaces GVFL24N
24 pages 2.16 mb -
Indoor Fireplace
Napoleon Fireplaces GD80PT
28 pages 2.54 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Napoleon Fireplaces BGD90NT, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Napoleon Fireplaces BGD90NT one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Napoleon Fireplaces BGD90NT. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Napoleon Fireplaces BGD90NT should contain:
- informations concerning technical data of Napoleon Fireplaces BGD90NT
- name of the manufacturer and a year of construction of the Napoleon Fireplaces BGD90NT item
- rules of operation, control and maintenance of the Napoleon Fireplaces BGD90NT item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Napoleon Fireplaces BGD90NT alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Napoleon Fireplaces BGD90NT, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Napoleon Fireplaces service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Napoleon Fireplaces BGD90NT.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Napoleon Fireplaces BGD90NT item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 W415-0614 / A / 07.24.07 INSTALLATION AND OPERATION INSTRUCTIONS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER . CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST[...]
-
Page 2
2 W415-0614 / A / 07.24.07 PG2-5 INTRODUCTION W arnings and Safety Precautions W arranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-9 VENTING V ent lengths V enting Specifi cations Air T erminal Locations 10-14 INST ALLA TION/FRAMING W all & Ceiling Protection Using Flexible V ent Components Fireplac[...]
-
Page 3
3 W415-0614 / A / 07.24.07 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON®® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. P A TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915. © WOLF STEEL L TD. NAPOLEON® products are manufactured under the strict Standard of the wo[...]
-
Page 4
4 W415-0614 / A / 07.24.07 6" Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operat- ing the fireplace. Never obstruct the front opening of the fireplace. Objects placed in fr ont of the fire place must be k ept a minimum of 48” from the fr ont face of the unit. Minimum clearance t[...]
-
Page 5
5 W415-0614 / A / 07.24.07 We Suggest that our gas hearth products be installed and serviced by profession- als who are certified in the U.S. by the National Fire- place Institute (NFI) as NFI Gas Specialists. 24" 16" 12" Do not use abrasive cleaners to clean glass. Buff lightly with a clean dry cloth. The glass is 3/16” tempered g[...]
-
Page 6
6 W415-0614 / A / 07.24.07 Simple venting confi guration (only one 90° elbow) VERTICAL RISE IN FEET V T FIGURE 4 See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 90° elbow , the following formulas apply: F or mula 1: H T < V T F or mula 2: H T + V T &[...]
-
Page 7
7 W415-0614 / A / 07.24.07 H 2 H 1 V 1 90° See graph to determine the required vertical rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .0 3 (t wo 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft H T = H R + H O = 8 + 2.7 = 10.7 ft H T + V T = 10.7 + 6 =16.7 Formula 1: H T [...]
-
Page 8
8 W415-0614 / A / 07.24.07 MAXIMUM VERTICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T . See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than two 90° elbow (top exit) [...]
-
Page 9
9 W415-0614 / A / 07.24.07 AIR TERMINAL INST ALLA TIONS * * * * * Recommended to prevent condensation on windows and thermal breakage ** ** ** ** ** It is recommended to use a hea t shield and to maximize the distance to vinyl c lad so ts . *** *** *** *** *** The periscope GD-401 requir es a minimum 18 inc hes cle arance fr om an inside corner [...]
-
Page 10
10 W415-0614 / A / 07.24.07 This application occurs when venting through an exterior wall. Having determined the air terminal loca- tion, cut and frame a hole in an exterior wall. The recommended framed opening is 14 1 / 2 ” W x 14 1 / 2 ” H with a minimum 14 1 / 2 ” round or square opening inside a fi nished wall. See fi gure15. 1. Mark an[...]
-
Page 11
11 W415-0614 / A / 07.24.07 7. Using the 10” diameter fl exible aluminium liner , apply sealant, slide a minimum of 2” over the fi replace combustion air collar and secure with 6 #8 screws. 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the ve[...]
-
Page 12
12 W415-0614 / A / 07.24.07 Pr oceed once the vent installa tion is complete . Note : All gas connections m ust be contained within the fireplace when complete . 1. The fi replace is designed to accept a ½” gas supply line. The fi replace is equipped with a ½” manual shut-off valve, and an 18” listed fl exible gas connector . 2. The acce[...]
-
Page 13
13 W415-0614 / A / 07.24.07 WARNING F acing and/or fi nishing material must ne ver o verhang into the fi replace opening. 59 1 /4 " 1" MIN 1" MIN 29" 10" MIN 72" 29" 59 1/4 " 59 1/4 " 29" 59 1/4 " 1 16" 82" FRAMING CLEARANCE T O COMBUSTIBLES MAINT AIN THESE MINIMUM CLEARANCES TO COM[...]
-
Page 14
14 W415-0614 / A / 07.24.07 FIGURE 30 MANTLE CLEARANCES 0 34 7 8 9 12 5 6 7 H E I G H T M A N T L E MANTLE WIDTH 5 6 4 3 Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed. Do NO T use the fireplace if any part has been under water . Call a qualified service technician IMMEDIA TE[...]
-
Page 15
15 W415-0614 / A / 07.24.07 1 . Place the door frame face down careful not to scratch the paint. 2 . Center the gasketed glass inside the door frame with the thick side of the gasket facing up. 3 . Bend the glass retainers located along the edge of the door frame over the gasket holding the glass in place. Careful not to break the glass. LOG SHIPPI[...]
-
Page 16
16 W415-0614 / A / 07.24.07 NOTE: Refer to the FINISHING section of the BGD90NT/ PT Installation Manual for instructions on removing the door and log shipping bracket before proceeding. Brick panels are shipped separate from unit due to the brittle material of the bricks, care must be taken not to bend or force them into place. When shipped, the br[...]
-
Page 17
17 W415-0614 / A / 07.24.07 6. Place the pin in log #7 in the hole in log #6. The log should sit in the notch on log #2 and the bottom should rest along the right side of the Andiron. 7. Place the large end of log#8 into the rear notch of log#4. The small branch of log#8 sits in the notch located on top of log#1. 8 PHAZER™ logs and glowing embers[...]
-
Page 18
18 W415-0614 / A / 07.24.07 GLO WING EMBERS CHARCO AL EMBERS Randomly place the charcoal embers along the front and sides of the Hearth Panels in a realistic manner . Fine dust found in the bottom of the bag should not be used. Sprinkle vermiculite around the charcoal embers. Note: Both charcoal embers and vermiculite are not to be placed on the bu[...]
-
Page 19
19 W415-0614 / A / 07.24.07 RECEIVER SLO T SP ARK MODULE VA LV E WING NUT 1. Remove access panel from inside the fi rebox. 2. Unplug the control module from the junction box 3. Pull up on the control module being held down with velcro and disconnect the plugs (fan, aux). Remove wiring harness from the front of casing. 4. Install the new control mo[...]
-
Page 20
20 W415-0614 / A / 07.24.07 T o operate this fi replace using the remote, the pilot must be running and the gas valve turned to the “ON” position. Ensure that the receiver has power and the backup switch is in the auto position. 1. Install the batteries (AAA) into the remote control transmitter . The “HOUSE” icon with room temperature will[...]
-
Page 21
21 W415-0614 / A / 07.24.07 5. F AN SPEED SETTING This function controls the speed of the hot air circulating fan. T o change the fan speed, use the UP and Down button until the cursor (small triangle) is left of the fan icon. Set to one of 4 levels included or turned off (level 4 means full speed) 6. TIMER SETTING The Remote Control has a sleep fu[...]
-
Page 22
22 W415-0614 / A / 07.24.07 ADDRESS SETTING PROCEDURE Use the UP and DOWN key on the transmitter until the cursor (small triangle) is left of the clock icon. From time 0:00 press the LEFT key ten times. The display will show then the trans- mitter address. Press the LEFT key to exit this function. The transmitter address is required to be equal to [...]
-
Page 23
23 W415-0614 / A / 07.24.07 DIP SWIT CH NUMBER (0 = ON / 1 = OFF)[...]
-
Page 24
24 W415-0614 / A / 07.24.07 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor . C. Use only your hand to turn the gas control [...]
-
Page 25
25 W415-0614 / A / 07.24.07 ADJUSTMENTS TURN OFF THE G AS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPL ACE. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after ser- vicing. This fi replace and its venting system should be inspected bef[...]
-
Page 26
26 W415-0614 / A / 07.24.07 PILOT BURNER THERMOCOUPLE THERMOPILE FLAME MUST ENVELOP UPPER 3/8” T O 1/2” OF THERMOCOUPLE & THERMOPILE Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may[...]
-
Page 27
27 W415-0614 / A / 07.24.07 # P ART NO. DESCRIPTION 1* W390-0002 DOOR LA TCH ( EA ) 2 W725-0047 NA TURAL GAS V AL VE - MODULA TING 2 W725-0048 PROP ANE GAS VAL VE - MODULATING 3 W455-0040 #41 NA TURAL GAS ORIFICE 3 W455-0058 #35 NA TURAL GAS ORFICE 3 W455-0059 #53 PROP ANE GAS ORIFICE 4 W680-0014 THERMOCOUPLE 5 W240-0008 ELECTRODE C / W LEAD 6 W680[...]
-
Page 28
28 W415-0614 / A / 07.24.07 6 4 8 7 5 40 22 27 28 29 30 34 26 25 33 61 32 61 31 11 62 20 2 14 15 12 3 13 18 16 68 52 55 21 76 43 66 67 AUX ON 0:00 00 ON/OFF FEATURE SELECT * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting ther- mocouple supplied by Wolf Steel Ltd.[...]
-
Page 29
29 W415-0614 / A / 07.24.07 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become per- manently marked. Carbon is being de- posited on glass,[...]
-
Page 30
30 W415-0614 / A / 07.24.07 Main burner goes out; pilot goes out. Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo- pile - turn up pilot fl ame. - replace pilot assembly . Thermopile shorting - clean thermopile connection to the valve. Reconnect. - test and replace thermopile if required. T empe[...]
-
Page 31
31 W415-0614 / A / 07.24.07 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SER VICE PERFORMANCE SPECIAL CONCERNS[...]
-
Page 32
32 W415-0614 / A / 07.24.07 NO TES[...]