Go to page of
Similar user manuals
-
Indoor Fireplace
Napoleon Fireplaces EF31H
12 pages 2.67 mb -
Indoor Fireplace
Napoleon Fireplaces GT8N
22 pages 3.02 mb -
Indoor Fireplace
Napoleon Fireplaces GDS28P
48 pages 2.24 mb -
Indoor Fireplace
Napoleon Fireplaces Fireplace
22 pages 3.02 mb -
Indoor Fireplace
Napoleon Fireplaces GD80PT
28 pages 2.54 mb -
Indoor Fireplace
Napoleon Fireplaces GDS25N GDS25P
28 pages 3.75 mb -
Indoor Fireplace
Napoleon Fireplaces BGD90NT
32 pages 4.13 mb -
Indoor Fireplace
Napoleon Fireplaces GD80NT
28 pages 2.54 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Napoleon Fireplaces BGNV36N, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Napoleon Fireplaces BGNV36N one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Napoleon Fireplaces BGNV36N. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Napoleon Fireplaces BGNV36N should contain:
- informations concerning technical data of Napoleon Fireplaces BGNV36N
- name of the manufacturer and a year of construction of the Napoleon Fireplaces BGNV36N item
- rules of operation, control and maintenance of the Napoleon Fireplaces BGNV36N item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Napoleon Fireplaces BGNV36N alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Napoleon Fireplaces BGNV36N, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Napoleon Fireplaces service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Napoleon Fireplaces BGNV36N.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Napoleon Fireplaces BGNV36N item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 W415-0275 / C / 09.23.05 R-2000 CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS, C SA 2.22, AND ANSI Z21.50 RESPECTIVEL Y FOR VENTED GAS FIREPLACES. MILLIVOL T SYSTEM INST ALLA TION AND OPERA TION INSTRUCTIONS FOR VENTED GAS FIREPLACE NA TURAL GAS MODEL BGNV36N PROP ANE GAS MODEL BGNV36P CERTIFIED FOR CANADA AND UNITED STATES USING ANS[...]
-
Page 2
2 W415-0275 / C / 09.23.05 WARNING • The product is a vented gas fireplace. Do not burn wood or other materials in this fireplace. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the[...]
-
Page 3
3 W415-0275 / C / 09.23.05 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired[...]
-
Page 4
4 W415-0275 / C / 09.23.05 Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. Manifold pressure under flow conditions is 3.5 inches water column for natural gas and 10 inches w[...]
-
Page 5
5 W415-0275 / C / 09.23.05 This is a vented appliance and must be connected to a chimney in accordance with the current installation codes. In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. This model can be common-vented. A minimum four inch diameter (4"ø) [...]
-
Page 6
6 W415-0275 / C / 09.23.05 P I P I L O T 3 1 2 N O L O T H I L O F F O It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local building codes. Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the firep[...]
-
Page 7
7 W415-0275 / C / 09.23.05 Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clear- ance needed. FIGURE 13 a FIGURE 13 b NAILING T AB FIGURE 1 1 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws sup- plied. Secure through the centre of the top and bottom slots in the [...]
-
Page 8
8 W415-0275 / C / 09.23.05 The upper louvres must be removed to allow the door to be opened or closed. To access the lower door latch, open the valve con- trol door. Release the top and bottom door latches, lo- cated at the right side of the door. UPPER L OUVRE S : Insert the upper louvres into the slots on both brackets. Press the top flange of th[...]
-
Page 9
9 W415-0275 / C / 09.23.05 4. Position the notch located on the end of the center log (#5) against the middle grate post with the other end of the log resting in the pocket of the left crossover log. 5. Place the bottom of the right crossover log (#6) against the right firebox side and pulled forward to the grate. The top of the log should rest in [...]
-
Page 10
10 W415-0275 / C / 09.23.05 Attach the connectors from the black and white wires to the thermodisc and se- cure the thermodisc bracket to the securing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the firebox wall. Attach the connectors from the black and red wires to the blower. Attach and[...]
-
Page 11
11 W415-0275 / C / 09.23.05 RECEPTACLE / JUNCTION BOX OPTIONAL THERMOSTATIC SENSOR SLOTS OPEN ENDED BRACKET VARIABLE SPEED/ PIEZO IGNITOR JUNCTION BOX THERMODISC SENSOR ASSEMBLY BRACKET RECEPTACLE / Attach and secure the sensor assembly bracket to the se- curing stud located next to the receptacle/junction box at the bottom left of the unit using t[...]
-
Page 12
12 W415-0275 / C / 09.23.05 FLAME ADJUSTMENT KNOB O T P I L L O I H T P I L O N O F F O PILOT ON/OFF KNOB • T urn off all gas to the fireplace. • O pen windows. • D o not try to light any appliance. • D o not touch any electric switch; do not use any phone in your building. • I mmediately call your gas supplier from a neighbour's pho[...]
-
Page 13
13 W415-0275 / C / 09.23.05 AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED GAS INSTALLER! Air shutter is accessed beside gas valve. P I P I PILOT SCREW L O T N O L O T H I L O F F O Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow. Closing the air shutter will cause a more yellow [...]
-
Page 14
14 W415-0275 / C / 09.23.05 # P AR T NO . DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE 4 W010-0764 BURNER 5 W010-0800 NA TURAL GAS PILOT ASSEMBL Y 5 W010-0801 PROP ANE GAS PILOT ASSEMBL Y 6 W660-0021 SAFETY SWITCH 7 W660-0007 HI LIMIT SWITCH 8* W660-0005 ON/OFF TOGGLE SWITCH 9 W455-0069 NA TURAL GAS PILOT IN[...]
-
Page 15
15 W415-0275 / C / 09.23.05[...]
-
Page 16
16 W415-0275 / C / 09.23.05 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor. - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed. - replace the electrode if the ceramic insulator is cracked or broken. - replace t[...]
-
Page 17
17 W415-0275 / C / 09.23.05 P I A B P I L O T N O L O T H I L O F F O White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a recommended gas fireplace glass cleaner. DO NOT CLEAN GLASS WHEN HO T. If deposits are not cleaned off regularly, the glass may become permanent[...]
-
Page 18
18 W415-0275 / C / 09.23.05 Wol f Steel Fireplace Service History This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name[...]
-
Page 19
19 W415-0275 / C / 09.23.05 NO TES[...]
-
Page 20
20 W415-0275 / C / 09.23.05 NO TES[...]