Go to page of
Similar user manuals
-
Indoor Fireplace
Napoleon Fireplaces GT8P
22 pages 3.02 mb -
Indoor Fireplace
Napoleon Fireplaces EF30
16 pages 0.63 mb -
Indoor Fireplace
Napoleon Fireplaces BGD40-N
36 pages 2.36 mb -
Indoor Fireplace
Napoleon Fireplaces GVFL24P
24 pages 2.16 mb -
Indoor Fireplace
Napoleon Fireplaces GVFS60-N
16 pages 0.31 mb -
Indoor Fireplace
Napoleon Fireplaces NZ25
16 pages 0.72 mb -
Indoor Fireplace
Napoleon Fireplaces GDS26N
32 pages 4.21 mb -
Indoor Fireplace
Napoleon Fireplaces GD82NT
34 pages 7.27 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Napoleon Fireplaces GDI30, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Napoleon Fireplaces GDI30 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Napoleon Fireplaces GDI30. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Napoleon Fireplaces GDI30 should contain:
- informations concerning technical data of Napoleon Fireplaces GDI30
- name of the manufacturer and a year of construction of the Napoleon Fireplaces GDI30 item
- rules of operation, control and maintenance of the Napoleon Fireplaces GDI30 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Napoleon Fireplaces GDI30 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Napoleon Fireplaces GDI30, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Napoleon Fireplaces service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Napoleon Fireplaces GDI30.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Napoleon Fireplaces GDI30 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 W415-0806 / 06.28.09 $10.00 INST ALLER: LEA VE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RET AIN THIS MANUAL FOR FUTURE REFERENCE. INST ALLA TION AND OPERA TING INSTRUCTIONS 1.2 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky , USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www .napo[...]
-
Page 2
2 W415-0806 / 06.28.09 T ABLE OF CONTENTS 1.0 INTRODUCTION 3 1.1 W ARRANTY 4 1.2 DIMENSIONS 5 1.3 INST ALLA TION OVERVIEW 5 1.4 GENERAL INSTRUCTIONS 6 1.5 GENERAL INFORMA TION 7 1.6 CARE OF GLASS 7 2.0 INST ALLA TION 8 2.1 INSERT LEVELLING 8 2.2 CHIMNEY CONNECTION 8 2.3 GAS INST ALLA TION 10 2.4 OPTIONAL WALL SWITCH 10 3.0 FRAMING 11 3.1 MINIMUM MA[...]
-
Page 3
3 W415-0806 / 06.28.09 3.1 ! W ARNING • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi re or injury . • Risk of fi re or asphyxiation do not operate appliance with fi xed glass removed. • Do not connect 1 10 volts to the contr[...]
-
Page 4
4 W415-0806 / 06.28.09 NAPOLEON® warrants its products against manufacturing defects to the original purchaser only . Registering your warranty is not necessary . Simply provide your proof of purchase along with the model and serial number to make a warranty claim. NAPOLEON® reserves the right to have its representative inspect any product or par[...]
-
Page 5
5 W415-0806 / 06.28.09 1.2 DIMENSIONS 27 1 / 4 " 19 5 / 8 " 17 7 / 8 " 18 3 / 4 " 30 1 / 16 " 11 1 / 8 " 5 1 / 4 " 1 3 / 8 " 23 1 / 8 " 21 3 / 4 " 3" ø collars 13 3 / 4 " 13 3 / 4 " Rating Plate Location 1.3 INST ALLA TION O VERVIEW V enting, see “INST ALLA TION - CHIMNEY CONNECTIO[...]
-
Page 6
6 W415-0806 / 06.28.09 1.4 GENERAL INSTRUCTIONS AL W A YS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPL Y HAS RAN OUT , WITH THE GLASS DOOR OPENED OR REMOVED. PROVIDE ADEQUA TE ACCESSIBILITY CLEARANCE FOR SERVICING AND OPERA TING THE APPLIANCE. PROVIDE ADEQUA TE VENTILA TION. NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. OBJEC[...]
-
Page 7
7 W415-0806 / 06.28.09 64.5% GDI-30 1.5 GENERAL INFORMA TION FOR YOUR SA TISF ACTION, THIS APPLIANCE HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! MINIMUM INLET : Gas supply pressure is 4.5 inches water column for natural gas and 1 1 inches water column for propane. MAXIMUM INLET : Gas pressure is 7 inches water column for natural gas [...]
-
Page 8
8 W415-0806 / 06.28.09 2.0 INST ALLA TION ! W ARNING RISK OF FIRE, MAINT AIN SPECIFIED AIR SP ACE CLEARANCES TO VENT PIPE AND APPLIANCE. Clean out ashes from the inside of the wood-burning appliance. Make sure that the chimney and wood-burning appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary ha[...]
-
Page 9
9 W415-0806 / 06.28.09 While the liners must be continuous from the appliance to the chimney cap, to achieve the needed length, they may be coupled, using an approved coupler . We recommend that exhaust vents that pass through unheated spaces, such as tall exterior chimneys, be wrapped in a protective sleeve to mini- mize condensation and reverse ?[...]
-
Page 10
10 W415-0806 / 06.28.09 2.3 GAS INST ALLA TION ! W ARNING RISK OF FIRE, EXPLOSION OR ASPHYXIA TION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SP ARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN A TT ACHING GAS SUPPL Y PIPE TO PREVENT DAMAGING GAS LINE. AL W A YS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPL Y HAS RUN OUT WITH THE G[...]
-
Page 11
11 W415-0806 / 06.28.09 3.0 FRAMING Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. These same requirements apply to any combustibles protruding on either side of the appli- ance. 3.1 MINIMUM MANTEL CLEARANCES ! W ARNING RISK OF FIRE, MAINT AIN ALL SPECIFIED AIR SP ACE CLEARA[...]
-
Page 12
12 W415-0806 / 06.28.09 4.0 FINISHING The upper louvres must be removed to allow the door to be opened or closed. T o access the lower door latch, open the valve control door . Release the top and bottom door latches, located at the right side of the door . NOTE: The protective wrap on plated parts is best removed when the assembly is at room tempe[...]
-
Page 13
13 W415-0806 / 06.28.09 4.4 LOG PLA CEMENT PHAZER TM logs and glowing embers exclusive to Napoleon, provide a unique and realistic glowing effect that is different in every installation. T ake the time to carefully position the glowing embers for a maximum glowing effect. Log colours may vary . During the initial use of the appliance, the colours w[...]
-
Page 14
14 W415-0806 / 06.28.09 4.4.3 Position the front right log just behind the grate lining up the holes in the bottom with the studs located on the log support. 4.4.4 Move the left log into position lining up the hole in the bottom with the stud on the left side of the log support. 4.4.5 Line up the square hole in the right crossover with the square p[...]
-
Page 15
15 W415-0806 / 06.28.09 5.0 OPTIONAL BL O WER INST ALLA TION FIGURE 8 FRONT BLOWER ACCESS COVER THERMODISC / BRACKET ASSEMBL Y REAR BLOWER ACCESS COVER 5.0.1 T urn off the electrical power and the gas supply to the appli- ance insert. 5.0.2 Open the glass door and remove the logs and fi bre bricks, if installed. 5.0.3 Remove the front blower acces[...]
-
Page 16
16 W415-0806 / 06.28.09 6.0 OPERA TION IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. AL W A YS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPL Y HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED. ! W ARNING A ssure that a continuous gas fl[...]
-
Page 17
17 W415-0806 / 06.28.09 7.0 ADJUSTMENTS 7.1 PILO T B URNER ADJUSTMENT Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow . Inlet pressure can be checked by turning screw (A) counter- clockwise until loosened and then placing pressure gauge tubing over the test point. Gauge should read 7?[...]
-
Page 18
18 W415-0806 / 06.28.09 8.0 MAINTENANCE CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. This fi replace and its venting system should be inspected before use and at least annually by a quali fi ed service person. The fi re[...]
-
Page 19
19 W415-0806 / 06.28.09 Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor . FOR W ARRANTY REPLACEMENT P ARTS, A PHOT OCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM. When ordering replacement parts al[...]
-
Page 20
20 W415-0806 / 06.28.09 7 6** 19 5 25 1 4 13 15 14 11 12 10 24 2 3 18 16 1 TERMINAL KITS REF NO. APPLIANCE DESCRIPTION 25* GDI-226 TERMINAL VENT KITS REF NO. APPLIANCE DESCRIPTION 1-2" & 1-3" DOUBLE PL Y ALUMINUM LINER-INLET AND EXHAUST & 2-3" TO 2" REDUCER: 26* GDI-2320KT VENT KIT 20FT 26* GDI-2325KT VENT KIT 25FT 26* G[...]
-
Page 21
21 W415-0806 / 06.28.09 ACCESSORIES REF NO. APPLIANCE DESCRIPTION 1 GI-1LK BLACK UPPER & LOWER LOUVRES 1 GI-1LPB BLACK UPPER & POLISHED BRASS LOWER LOUVRES 1 GI-1LAB BLACK UPPER & ANTIQUE BRASS LOWER LOUVRES 1 GI-1LSS BLACK UPPER & BRUSHED ST AINLESS STEEL LOWER LOUVRES 1 GI-OIG GOLD PLA TED UPPER & LOWER LOUVRES 2 GI-OIK BLACK [...]
-
Page 22
22 W415-0806 / 06.28.09 3 1 4 4 4 14[...]
-
Page 23
23 W415-0806 / 06.28.09 10.0 TR OUBLE SHOO TING ! W ARNING AL W A YS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPL Y HAS RAN OUT , WITH THE GLASS DOOR OPEN OR REMOVED. SYMPTOM PROBLEM TEST SOLUTION Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engul fi ng the thermopile. - Turn up the pilot fl ame[...]
-
Page 24
24 W415-0806 / 06.28.09 SYMPTOM PROBLEM TEST SOLUTION Pilot goes out while standing; Main burner is in ‘OFF’ position. Gas piping is undersized. - Turn on all gas appliances and see if pilot fl ame fl utters, diminishes or extinguishes, especially when main burner ignites. Monitor appliance supply working pressure. - Check if supply piping si[...]
-
Page 25
25 W415-0806 / 06.28.09 11.0 SER VICE HIST OR Y Appliance Ser vice Histor y This heater must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name 43.1[...]
-
Page 26
26 W415-0806 / 06.28.09 44.1 12.0 NO TES[...]