Go to page of
Similar user manuals
-
Indoor Fireplace
Napoleon Fireplaces BGNV40-P
28 pages 1.2 mb -
Indoor Fireplace
Napoleon Fireplaces EPA1400
20 pages 1.08 mb -
Indoor Fireplace
Napoleon Fireplaces BGD40-N
36 pages 2.36 mb -
Indoor Fireplace
Napoleon Fireplaces GDS60N
52 pages 3.84 mb -
Indoor Fireplace
Napoleon Fireplaces GVFL24P
24 pages 2.16 mb -
Indoor Fireplace
Napoleon Fireplaces NZ25
16 pages 0.72 mb -
Indoor Fireplace
Napoleon Fireplaces BGNV36N
20 pages 5.03 mb -
Indoor Fireplace
Napoleon Fireplaces EF30G
20 pages 2.19 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Napoleon Fireplaces GDS20P, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Napoleon Fireplaces GDS20P one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Napoleon Fireplaces GDS20P. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Napoleon Fireplaces GDS20P should contain:
- informations concerning technical data of Napoleon Fireplaces GDS20P
- name of the manufacturer and a year of construction of the Napoleon Fireplaces GDS20P item
- rules of operation, control and maintenance of the Napoleon Fireplaces GDS20P item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Napoleon Fireplaces GDS20P alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Napoleon Fireplaces GDS20P, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Napoleon Fireplaces service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Napoleon Fireplaces GDS20P.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Napoleon Fireplaces GDS20P item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 W415-0496 / B / 08.10.05 W415-0496 / B / 08.10.05[...]
-
Page 2
2 W415-0496 / B / 08.10.05 WHA T T O DO IF Y OU SMELL GAS WARNINGS & SAFETY PRECA UTIONS[...]
-
Page 3
3 W415-0496 / B / 08.10.05 WARNING • The sto ve is a vented g as-fi r ed hea ter . Do not b urn wood or other materials in this sto ve . • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when the stove is h[...]
-
Page 4
4 W415-0496 / B / 08.10.05 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired[...]
-
Page 5
5 W415-0496 / B / 08.10.05 Expansion / contraction noises during heating up and cool- ing down cycles are normal and to be expected. This appliance is only for use with the type of gas indicated on the rating plate . This appliance is not convertible for use with other gases, unless a certified kit is used. Do not use abrasive cleaners to clean the[...]
-
Page 6
6 W415-0496 / B / 08.10.05 MAINT AIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES: A. 4" B. 2" * C. 2" STOVE SHOULD NOT BE INST ALLED DIRECTL Y ON CARPETING . MINIMUM 48" FROM STOVE TOP TO CEILING TO CEILING FROM STOVE TOP .......................................48" HORIZONT AL VENT SIDES AND BOTTOM .............................[...]
-
Page 7
7 W415-0496 / B / 08.10.05 BLO WER INST ALLA TION Blower ( SEE LOCATION AND CLEARANCES ) 1. Cut and remove the tie securing the blower switch wires to the heat shield. 2. Connect the white wire coming from below the unit to the terminal on the blower . 3. Connect the black blower wire to the black wire coming from below the unit. 4. Insert the clip[...]
-
Page 8
8 W415-0496 / B / 08.10.05 AIR TERMINAL INST ALLA TIONS * * * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * It is recommended t o use a heat shield and to maximize the distance to vinyl c lad sof fits . *** *** *** *** ** * The periscope GD-201 requires a minimum 18 inches clear ance from an inside corn[...]
-
Page 9
9 W415-0496 / B / 08.10.05 Use only Wolf S teel, Simpson Dura-V ent, Selkirk Direct T emp or American Met al Amerivent venting components. For Simpson Dura-V ent, Selkirk Direct T emp and American Metal Amerivent, follow the installation procedure provided with the venting components. All outer pipe joints of these venting systems must be sealed us[...]
-
Page 10
10 W415-0496 / B / 08.10.05 Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated. FIGURES 3 a-c FIGURE 4 TYPICAL VE[...]
-
Page 11
11 W415-0496 / B / 08.10.05 ELBO W VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMIN A TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) for the following symbols used in the venting calcula- tions and examples are: > - greater tha[...]
-
Page 12
12 W415-0496 / B / 08.10.05 V 1 HORIZONT AL TERMINA TION See graph to determine the re- quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 24.75 feet FIGURE 7 REQUIRED VERTICAL RISE IN[...]
-
Page 13
13 W415-0496 / B / 08.10.05 VERTICAL TERMIN A TION Example 3: V 1 =5 f t V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 =3 f t H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T = 10.9 + 15 = 25.9 ft Formula 1: H T < V [...]
-
Page 14
14 W415-0496 / B / 08.10.05 H 1 VERTICAL TERMIN A TION For vent configurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 f eet when (H T ) > (V T ) Simple venting configurations See graph to determine the required vertical rise V T for the required ho[...]
-
Page 15
15 W415-0496 / B / 08.10.05 This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum rectangle opening of 10" x 9". IMPORT ANT : FOR OPTIMUM PERFORMANCE, THE STOVE PIPE SHOULD RISE ¼" PER FOOT OF RUN. 1. Assemble the shield to [...]
-
Page 16
16 W415-0496 / B / 08.10.05 4. If more than one length of liner needs to be used to reach the stove, couple them together as illustrated in FIGURE 24 . Seal the joints using the same procedure as described above. The vent system must be supported approximately every 10 feet along a horizontal run. Use supports or equivalent non-combustible strappin[...]
-
Page 17
17 W415-0496 / B / 08.10.05 1. Attach the adjustable pipe to the last section of rigid piping. Secure with screws and seal. 2. Install the 4" aluminium flex- ible liner to the stove. Secure with 3 screws and flat wash- ers. Seal the joint and screw holes using high tempera- ture sealant. 3. Run a bead of high tem- perature sealant Mill Pac aro[...]
-
Page 18
18 W415-0496 / B / 08.10.05 1. Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by removing the screws from the brackets located in the upper inside corners. 3. Slide the front straight up to remove. FINISHING GLASS DOOR INST ALLA TION AND REMO V AL CAST FRONT INST ALLA TION AND REMO V AL Note: It is not [...]
-
Page 19
19 W415-0496 / B / 08.10.05 LOG PLACEMENT LOGO PLACEMENT Remove the backing from the the logo and position onto the control door as shown. It is not necessary to rem ove the cast fr ont, however , this will make for a more simple log installation. In order to assemble the log set, the door must be removed, see Cast Front / Glass Door Removal in the[...]
-
Page 20
20 W415-0496 / B / 08.10.05 Purge all gas lines with the glass door removed. Assure that a continuous gas flow is at the burner before closing the door . The on-off switch is located on the back of the unit at the top right corner on model GDS20. When lit for the first time, the fireplace will emit a slight odour for a few hour s . This is a normal[...]
-
Page 21
21 W415-0496 / B / 08.10.05 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . FIGURE 34 FIGURE 35 Air shutter adjustment must only be done by a qualified gas installer! FIGURE 36 ADJUSTMENTS PILOT BURNER ADJUSTMENT VENTURI ADJUSTMENT TURN OFF THE GAS AND UNPL UG ELECTRICAL POWER BEFORE SE[...]
-
Page 22
22 W415-0496 / B / 08.10.05 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor . When ordering replacement parts always give the fol- lowing information: 1. M ODEL & S ERIAL N UMBER OF FIREPLACE 2. I NST ALLA TION DA TE OF FIREP[...]
-
Page 23
23 W415-0496 / B / 08.10.05 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.[...]
-
Page 24
24 W415-0496 / B / 08.10.05 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed. - replace the electrode if the ceramic insulator is cracked or broken. No spark a[...]
-
Page 25
25 W415-0496 / B / 08.10.05 Main burner goes out; pilot goes out. REFER TO "MAIN BURNER GOES OUT ; PILOT ST A YS ON" Thermocouple shorting or faulty . V ent re-circulating - check joint seals and installation. - loosen and tighten thermocouple - clean thermocouple and valve connection. - replace thermocouple. - replace valve. Exhaust fume[...]
-
Page 26
26 W415-0496 / B / 08.10.05 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name[...]
-
Page 27
27 W415-0496 / B / 08.10.05 NO TES[...]
-