Go to page of
Similar user manuals
-
Indoor Fireplace
Napoleon Fireplaces GVFL18N
24 pages 2.16 mb -
Indoor Fireplace
Napoleon Fireplaces EF34H
12 pages 1.84 mb -
Indoor Fireplace
Napoleon Fireplaces EF38H
12 pages 2.32 mb -
Indoor Fireplace
Napoleon Fireplaces GDI-30N
16 pages 0.71 mb -
Indoor Fireplace
Napoleon Fireplaces GE38NT-M
28 pages 3.31 mb -
Indoor Fireplace
Napoleon Fireplaces GVFS60-N
16 pages 0.31 mb -
Indoor Fireplace
Napoleon Fireplaces BGD48N
28 pages 2.45 mb -
Indoor Fireplace
Napoleon Fireplaces Fireplace
22 pages 3.02 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Napoleon Fireplaces GT8P, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Napoleon Fireplaces GT8P one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Napoleon Fireplaces GT8P. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Napoleon Fireplaces GT8P should contain:
- informations concerning technical data of Napoleon Fireplaces GT8P
- name of the manufacturer and a year of construction of the Napoleon Fireplaces GT8P item
- rules of operation, control and maintenance of the Napoleon Fireplaces GT8P item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Napoleon Fireplaces GT8P alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Napoleon Fireplaces GT8P, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Napoleon Fireplaces service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Napoleon Fireplaces GT8P.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Napoleon Fireplaces GT8P item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 W415-0619 / A / 08.09.07 INST ALLA TION AND OPERA TION INSTRUC TIONS W olf Steel Ltd ., 24 Napoleon Rd., Barrie, ON L4M 4Y8 C anada • (705)721-1212 • fax(705)722-6031 ww w .napoleonreplac es.com • ask@napoleon.on.ca INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REM AIN WITH THE HOMEOWNER. CERTIFIED UNDER CANADIAN AND AMERICAN NA[...]
-
Page 2
2 W415-0619 / A /08.09.07 PG 2-5 INTRODUCTION Warranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-6 VENTING V enting Lengths Air T erminal Locations 7-9 INST ALLA TION/FRAMING W all & Ceiling Protection Using Flexible V ent Components Horizontal Air T erminal Installation Fireplace V ent Connection Ga[...]
-
Page 3
3 W415-0619 / A / 08.09.07 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE T O ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. P A TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915. © WOLF STEEL L TD. NAPOLEON® products are manufactured under the strict Standard of the wor[...]
-
Page 4
4 W415-0619 / A /08.09.07 16 3 / 4 Minimum clearance to combustible construction from fi replace and vent surfaces: Fireplace framing: - 6” to top - 0” to stand-offs (rear and sides) V ent pipe: - 1” Recessed depth: - 7” FIGURE 1 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Ins[...]
-
Page 5
5 W415-0619 / A / 08.09.07 W ARNING DO NOT SUBSTITUTE MA TERIALS. USE CARE WHEN HANDLING GLASS COMPONENTS DO NOT STIKE, OR SLAM SHUT . DO NOT OPERA TE WITH BROKEN GLASS. The glass is 3/16” ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer . Clean the glass after the fi rst 10 hours of operation with a recommended gas fi repl[...]
-
Page 6
6 W415-0619 / A /08.09.07 N B B G A F C H H L K J M FIGURE 3[...]
-
Page 7
7 W415-0619 / A / 08.09.07 INST ALLA TION / FRAMING WALL AND CEILING PRO TECTION This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum square opening of 8” W x 8” H. IMPORT ANT : For optimum performance, The vent pipe should rise ¼” [...]
-
Page 8
8 W415-0619 / A /08.09.07 The has been designed to be installed mid-way up an outside wall. When installing this unit close to the fi nished fl oor , the unit must be raised a minimum of 2” (unobstructed) to allow for full rotation of the control door . It is not necessa ry to install a hearth extension. Although the unit fi ts between studs, [...]
-
Page 9
9 W415-0619 / A / 08.09.07 MAINT AIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES: Fireplace framing - 6” to top - 0” to stand-offs (rear and sides) Fireplace fi nishing - 0” FIGURE 14 Do NOT use the fi replace if any part has been under water . Call a quali fi ed service technician IMMEDIA TEL Y to have the fireplace inspected for damage to t[...]
-
Page 10
10 W415-0619 / A /08.09.07 FRAME INST ALLA TION 1. Align the two holes in the upper portion of the hinge on the control door assembly to those in the bottom trim bracket and secure using two of the screws supplied. (FIGURE 17) 2. Rest the top lip of the T orch TM frame on the top trim bracket, and the securing tabs at the bottom of the To r c h TM [...]
-
Page 11
11 W415-0619 / A / 08.09.07 A. This fi replace is equipped with an ignition device which automatically lights the burner . Do not try to light by hand. B. Before operating, smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor . C. Do not use this fi replace if an[...]
-
Page 12
12 W415-0619 / A /08.09.07 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame colour to be established. NOTE: It [...]
-
Page 13
13 W415-0619 / A / 08.09.07 # P ART NO. DESCRIPTION 1 W225-0216 DOOR FRAME 2* W562-0008 DOOR GASKET 3* W010-1736 DOOR LA TCH ASSEMBL Y 4 W010-1743 GLASS C / W GASKET 5* W300-0088 GLASS 6 W100-0104 BURNER 7 W357-0006 IGNITOR 8 W190-0026 CONTROL, MODULE 9* W750-0183 WIRE HARNESS 10* W750-0184 IGNITION CABLE 1 1 W200-0234 IGNITOR COVER 12 W200-0233 BU[...]
-
Page 14
14 W415-0619 / A /08.09.07 TR OUBLE SHOO TING GUIDE BEFORE A TTEMPTING TO TROUBLESHOOT , PURGE YOUR UNIT AND INITIALL Y LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR OPEN . SYMPTOM PROBLEM TEST SOLUTION Electrode sparks, burner ignites, electrode contiunes to spark for complete 7 seconds, burner shuts down. Hot and neutral wires are rev[...]
-
Page 15
15 W415-0619 / A / 08.09.07 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS[...]
-
Page 16
16 W415-0619 / A /08.09.07 NOTES[...]