A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Napoleon GVFL18, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Napoleon GVFL18 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Napoleon GVFL18. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Napoleon GVFL18 should contain:
- informations concerning technical data of Napoleon GVFL18
- name of the manufacturer and a year of construction of the Napoleon GVFL18 item
- rules of operation, control and maintenance of the Napoleon GVFL18 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Napoleon GVFL18 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Napoleon GVFL18, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Napoleon service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Napoleon GVFL18.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Napoleon GVFL18 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 W415-0809 / B / 01.07.1 1 INST ALLER: LEA VE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RET AIN THIS MANUAL FOR FUTURE REFERENCE. INST ALLA TION AND OPERA TING INSTRUCTIONS 1.23 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky , USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www .napol[...]

  • Page 2

    2 W415-0809 / B / 01.07.1 1 NOTE: Changes, other than editorial, are denoted by a vertical line in the margin. T ABLE OF CONTENTS 1.0 INST ALLA TION O VER VIEW Andiron, see “ ANDIRON AND GRA TE ASSEMBL Y” sec tion. Logs , see “L OG PLACEMENT ” section. Media, see “MEDIA ” section. Rating Plate, see “RA TING PLA TE INFORMA TION” sect[...]

  • Page 3

    3 W415-0809 / B / 01.07.1 1 3.12B ! W ARNING • THIS APPLIANCE IS HOT WHEN OPERA TED AND CAN CAUSE SEVERE BURNS IF CONT ACTED. • ANY CHANGES OR AL TERA TIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Under no circumstances should this appliance be modi fi ed. • Do not operate appliance before reading and unders[...]

  • Page 4

    4 W415-0809 / B / 01.07.1 1 2.1 DIMENSIONS 2.1.1 GVFL18 2.1.2 GVFL24 2.1.3 GVFL30 20.500 13.250 24.000 26.250 24.000 13.250 30.250 22.750 13.250 1.500 24.000[...]

  • Page 5

    5 W415-0809 / B / 01.07.1 1 2.2 GENERAL INSTRUCTIONS Thoroughly clean the chimney , fl ue and existing appliance before installing the new appliance into it. Do not burn solid fuels in any appliance that is equipped with this gas log set. The installation of this appliance must conform with local codes or in the absence of local codes with the Nat[...]

  • Page 6

    6 W415-0809 / B / 01.07.1 1 2.3 GENERAL INFORMA TION CARBON MONOXIDE POISONING MA Y LEAD TO DEA TH EARL Y SIGNS OF CARBON MONOXIDE POISONING RESEMBLE THE FLU, WITH HEADACHE, DIZZINESS AND/OR NAUSEA. IF YOU HA VE THESE SIGNS, THE APPLIANCE MA Y NOT BE WORKING PROPERL Y . GET FRESH AIR A T ONCE! HA VE APPLIANCE SER VICED. SOME PEOPLE--PREGNANT WOMEN,[...]

  • Page 7

    7 W415-0809 / B / 01.07.1 1 2.5 RA TING PLA TE INFORMA TION THIS APPLIANCE IS NOT FIELD CONVERTIBLE FOR USE WITH OTHER GASES. b 4 b 4 ANSI Z21.11.2a-2008 WOLF STEEL L TD. 24 NAPOLEON ROAD. BARRIE, ONT ARIO L4M 4Y8 CANADA W385-0317 / K XXXXXX THE RA TING PLA TE IS CHAINED TO THE PIEZO IGNIT OR BRACKET AND SHOULD BE TUCKED UNDER THE ENTIRE ASSEMBL Y [...]

  • Page 8

    8 W415-0809 / B / 01.07.1 1 3.0 INST ALLA TION 17.1A This appliance shall not be installed in a con fi ned space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air . The National Fuel Gas Code, ANSI Z223.1 / NFP A 54 de fi nes a con fi ned space as a space whose volume is less than 50 cubic[...]

  • Page 9

    9 W415-0809 / B / 01.07.1 1 19.2 EXAMPLE 1: In this example, because there is no door to the adjoining room, the volume of the adjoining room may be added to the volume of the room with the heater to get a total uncon fi ned space. The total uncon fi ned space: 800 + 1200 = 2000 cubic feet. Maximum BTU/h: 2000x1000 = 40,000 BTU/h 50 19.3 EXAMPLE [...]

  • Page 10

    10 W415-0809 / B / 01.07.1 1 3.2 INST ALLING IN A VENTED APPLICA TION 3.2.1 D AMPER ST OP INST ALLA TION DAMPER STOP DAMPER The damper must be permanently locked in position to prevent full closure and to provide a minimum fl ue opening. V arious methods for locking the damper may be used but may be restricted from region to region and it is impor[...]

  • Page 11

    11 W415-0809 / B / 01.07.1 1 3.3 GAS PIPING ! W ARNING DO NOT CONNECT EITHER THE W ALL SWITCH, THERMOST A T OR GAS V AL VE TO ELECTRICITY (1 10 VOL TS). This appliance and it’s appliance main valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ PSI (3.5kPa) This [...]

  • Page 12

    12 W415-0809 / B / 01.07.1 1 4.2 LOG PLA CEMENT Failure to position these logs in accordance with these diagrams or failure to use parts speci fi cally approved with this appliance may result in property damage or personal injury . Do not place glowing embers, charcoal embers, vermiculite or charcoal lumps on this burner . ! W ARNING Phazer TM log[...]

  • Page 13

    13 W415-0809 / B / 01.07.1 1 4.3 LOGO PLA CEMENT LO G O ½" LOGO ½" Remove the backing of the logo supplied. Centre the logo on the front of the appliance, ½” in from the left side, as shown. 4.4 MEDIA A. Place lava or ember rock around the base of the appliance, making sure not to block any burner ports or valve access. Retain a smal[...]

  • Page 14

    14 W415-0809 / B / 01.07.1 1 5.0 OPERA TING INSTR UCTIONS If the appliance is equipped with decorative glass doors, they must be fully opened when operating this gas log set. 5.1 LIGHTING INSTRUCTIONS A C D E B A. Locate the pilot burner at the rear of the log set on the right side. B. Turn the gas control knob to the pilot setting (on the left sid[...]

  • Page 15

    15 W415-0809 / B / 01.07.1 1 FOR Y OUR SAFETY READ BEFORE LIGHTING: Ɣ This appliance is equipped with a pilot which must be lit by hand while following these instructions exactly . Ɣ Before operating smell all around the appliance area for gas and next to the floor because some gas is heavier than air and will settle on the floor . Ɣ Use only[...]

  • Page 16

    16 W415-0809 / B / 01.07.1 1 7.0 ADJUSTMENTS 7.1 AIR SHUTTER ! W ARNING CARBON CAN BE DISTRIBUTED IN SURROUNDING LIVING AREAS IF THE AIR SHUTTER IS IMPROPERL Y ADJUSTED. F AILURE TO KEEP THE PRIMAR Y AIR OPENING(S) OF THE BURNER (S) CLEAN MA Y RESUL T IN SOOTING AND PROPERTY DAMAGE. LOG SET AIR SHUTTER FUEL NG LP GVFL18 9/32” 7/16” GVFL24 9/32?[...]

  • Page 17

    17 W415-0809 / B / 01.07.1 1 9.0 REPLA CEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor . FOR W ARRANTY REPLACEMENT P ARTS, A PHOT OCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM. When orderi[...]

  • Page 18

    18 W415-0809 / B / 01.07.1 1 7 2 1 4 3 13 12 8 10 11 9 20 15 1 5 6 16 17[...]

  • Page 19

    19 W415-0809 / B / 01.07.1 1 10.0 TR OUBLE SHOO TING SYMPTOM PROBLEM TEST SOLUTION Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engul fi ng the thermopile. - Ensure adequate supply pressure. - Replace pilot assembly . Thermopile shorting / loose connection. - Clean thermopile connection to the valve. Reconnect. - [...]

  • Page 20

    20 W415-0809 / B / 01.07.1 1 SYMPTOM PROBLEM TEST SOLUTION Pilot burning; no gas to main burner; gas knob is on ‘HI’; wall switch / thermostat is on. Thermostat or switch is defective. - Connect a jumper wire across the wall switch terminals; if main burner lights, replace switch / thermostat. W all switch wiring is defective. - Disconnect wire[...]

  • Page 21

    21 W415-0809 / B / 01.07.1 1 SYMPTOM PROBLEM TEST SOLUTION Flames are consistently too large or too small. Carboning occurs. Unit is over- fi red or under- fi red. - Check pressure readings: - Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Check with bu[...]

  • Page 22

    22 W415-0809 / B / 01.07.1 1 NAPOLEON® warrants its products against manufacturing defects to the original purchaser only . Registering your warranty is not necessary . Simply provide your proof of purchase along with the model and serial number to make a warranty claim. NAPOLEON® reserves the right to have its representative inspect any product [...]

  • Page 23

    23 W415-0809 / B / 01.07.1 1 12.0 SER VICE HIST OR Y 43.1[...]

  • Page 24

    24 W415-0809 / B / 01.07.1 1 44.1 13.0 NO TES[...]