Go to page of
Similar user manuals
-
Computer Accessories
National Instruments PXI-8461
49 pages 0.57 mb -
Computer Accessories
National Instruments NI-CANTM Software for Windows NT
49 pages 0.57 mb -
Computer Accessories
National Instruments NI 5911
61 pages 0.54 mb -
Computer Accessories
National Instruments NI cDAQ-9172
76 pages 1.96 mb -
Computer Accessories
National Instruments PXI-8460
49 pages 0.57 mb -
Computer Accessories
National Instruments 373873C-01
186 pages 3.12 mb -
Computer Accessories
National Instruments NI MATRIX Xmath Robust Control Module
71 pages 0.55 mb -
Computer Accessories
National Instruments 321518A-01
55 pages 0.66 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of National Instruments 321042A-01, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of National Instruments 321042A-01 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of National Instruments 321042A-01. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of National Instruments 321042A-01 should contain:
- informations concerning technical data of National Instruments 321042A-01
- name of the manufacturer and a year of construction of the National Instruments 321042A-01 item
- rules of operation, control and maintenance of the National Instruments 321042A-01 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of National Instruments 321042A-01 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of National Instruments 321042A-01, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the National Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of National Instruments 321042A-01.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the National Instruments 321042A-01 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
© Copyright 1995 National Instruments Corporation. All Rights Reserved. Getting Started with Your STD-GPIB and the NI-488.2 ™ Software for Windows December 1995 Edition Part Number 321042A-01[...]
-
Page 2
National Instruments Corporate Headquarters 6504 Bridge Point Parkway Austin, TX 78730-5039 (512) 794-0100 Technical support fax: (800) 328-2203 (512) 794-5678 Branch Offices: Australia 03 9 879 9422, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Canada (Ontario) 519 622 9310, Canada (Québec) 514 694 8521, Denmark 45 76 26 00, Finland 90 527 2321[...]
-
Page 3
Limited Warranty The STD-GPIB hardware is warranted against defects in materials and workmanship for a period of two years from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes pa[...]
-
Page 4
Copyright Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation. Trademarks LabVIEW ® , NAT4882 ®[...]
-
Page 5
FCC/DOC Radio Frequency Interference Compliance This equipment generates and uses radio frequency energy and, if not installed and used in strict accordance with the instructions in this manual, may cause interference to radio and television reception. This equipment has been tested and found to comply with the following two regulatory agencies: Fe[...]
-
Page 6
• Move the equipment away from the receiver with which it is interfering. • Reorient or relocate the receiver’s antenna. • Be sure that the equipment is plugged into a grounded outlet and that the grounding has not been defeated with a cheater plug. Notice to user: Changes or modifications not expressly approved by National Instruments coul[...]
-
Page 7
© National Instruments Corp. v i i STD-GPIB for Windows Contents About This Manual .............................................................................................. . i x How to Use the Manual Set ............................................................................ . i x Organization of This Manual ............................[...]
-
Page 8
Contents STD-GPIB for Windows v i i i © National Instruments Corp. Presence Test of Module .................................................... . 4- 5 GPIB Cables Connected .................................................... . 4-6 Common Questions ........................................................................................ . 4-6 Chapt[...]
-
Page 9
© National Instruments Corp. i x STD-GPIB for Windows About This Manual This manual contains instructions to help you install and configure the National Instruments STD-GPIB interface board and the NI-488.2 software for Windows. The interface board is intended for use in a STD/STD32 system. The NI-488.2 software is intended for use with Windows ve[...]
-
Page 10
About This Manual STD-GPIB for Windows x © National Instruments Corp. Organization of This Manual This manual is organized as follows: • Chapter 1, Introduction , explains how to use this manual, lists what you need to get started, and briefly describes the STD-GPIB and the NI -488.2 software. • Chapter 2, Hardware Configuration and Installati[...]
-
Page 11
About This Manual © National Instruments Corp. x i STD-GPIB for Windows monospace Text in this font denotes text or characters that are to be literally input from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, directories, programs, subprograms, subroutines, de[...]
-
Page 12
About This Manual STD-GPIB for Windows x i i © National Instruments Corp. Customer Communication National Instruments wants to receive your comments on our products and manuals. We are interested in the applications you develop with our products, and we want to help if you have problems with them. To make it easy for you to contact us, this manual[...]
-
Page 13
© National Instruments Corp. 1 -1 STD-GPIB for Windows Chapter 1 Introduction This chapter explains how to use this manual, lists what you need to get started, and briefly describes the STD-GPIB and the NI-488.2 software. How to Use This Manual No Chapter 4 T roubleshooting Ye s No Need to Change Software Settings? Passes? Install the Software V e[...]
-
Page 14
Introduction Chapter 1 STD-GPIB for Windows 1 -2 © National Instruments Corp. What You Need to Get Started STD-GPIB STD-GP I B feedthrough front panel assembly 3.5 in. high density (1.44 MB) distribution disk: NI-488.2 Software for Windows and the AT-GPIB/TNT+, AT-GPIB/TNT (PnP), EISA-GPIB and AT-GPIB/TNT Microsoft Windows version 3.1 installed on[...]
-
Page 15
Chapter 1 Introduction © National Instruments Corp. 1 -3 STD-GPIB for Windows Software Description The STD-GPIB uses the NI-488.2 driver software for the AT-GPIB/TNT. The NI -488.2 software for Windows includes a Windows dynamic link library, language interface libraries, and debugging and development utilities. The NI-488.2 software and GPIB hard[...]
-
Page 16
© National Instruments Corp. 2 -1 STD-GPIB for Windows Chapter 2 Hardware Configuration and Installation This chapter contains instructions to help you configure and install your STD-GPIB. Warning: Electrostatic discharge can damage some components on your S T D -GPIB. To avoid such damage in handling the module, touch the antistatic plastic packa[...]
-
Page 17
Hardware Configuration and Installation Chapter 2 STD-GPIB for Windows 2 -2 © National Instruments Corp. Install the Hardware Perform the following steps to install the STD-GPIB. 1 . Power off your STD/STD32 system. Keep the system plugged in so that it remains grounded while you install the STD-GPIB. 2 . Remove any front plates that are blocking [...]
-
Page 18
Chapter 2 Hardware Configuration and Installation © National Instruments Corp. 2 -3 STD-GPIB for Windows Note: If you plan to perform HS488 high-speed protocol transfers, you must configure the NI-488.2 software for the amount of GPIB cable length in your system. The 5 in. GPIB ribbon cable must be added to your total GPIB cable length. 5 . Mount [...]
-
Page 19
Hardware Configuration and Installation Chapter 2 STD-GPIB for Windows 2 -4 © National Instruments Corp. Configure the Hardware Follow the instructions in this section to change the hardware settings of the STD -GPIB before you install it. The default settings are suitable for most STD systems, but you need to change the hardware settings in the f[...]
-
Page 20
Chapter 2 Hardware Configuration and Installation © National Instruments Corp. 2 -5 STD-GPIB for Windows Figure 2-3 shows the location of the configuration jumpers and switches on the STD-GPIB. 1 8 7 6 2 3 4 5 1 Interrupt Level 3 Assembly Number 5 Product Name 7 Mode of Operation 2 DMA Channel 4 Serial Number 6 Shield Ground 8 Base I/O Add[...]
-
Page 21
Hardware Configuration and Installation Chapter 2 STD-GPIB for Windows 2 -6 © National Instruments Corp. Selecting the Base I/O Address STD/STD32 computers have a segment of address space reserved for input and output. This segment is referred to as the I/O address space. The base I/O address of an STD/STD32 module such as the STD-GPIB is the firs[...]
-
Page 22
Chapter 2 Hardware Configuration and Installation © National Instruments Corp. 2 -7 STD-GPIB for Windows Table 2-2. Possible Base I/O Address Switch Settings (Continued) Switch Setting A9 A8 A7 A6 A5 Base I/O Address (hex) I/O Address Space Used (hex) 1010 1 2 A 0 2 A 0 t o 2 B F 1011 0 2 C 0 2C0 to 2DF 1011 1 2 E 0 2E0 to 2FF 1100 0 3 0 0 300 to [...]
-
Page 23
Hardware Configuration and Installation Chapter 2 STD-GPIB for Windows 2 -8 © National Instruments Corp. Switch Set to Base I/O Address hex 300 Switch Set to Default Base I/O Address hex 2C0 9 8 7 6 5 Binary Hex 0 0 3 9 8 7 6 5 Binary Hex 0 C 2 0 1 1 0 0 0 0 0 0 0 0 1 0 1 1 0 0 0 0 0 0 1 2 3 4 5 0 OFF 1 1 1 2 3 4 5 OFF Push this side down (OFF) fo[...]
-
Page 24
Chapter 2 Hardware Configuration and Installation © National Instruments Corp. 2 -9 STD-GPIB for Windows Selecting the Interrupt Request Line STD/STD32 computers have a series of interrupt lines available to devices. Some of the interrupt lines reside in the backplane, and the others are available through a 10-pin frontplane connector. Devices use[...]
-
Page 25
Hardware Configuration and Installation Chapter 2 STD-GPIB for Windows 2 -10 © National Instruments Corp. Figure 2-5 shows the setting for IRQ11 in a Ziatech AT-compatible computer. IRQ 5 IRQ 6 IRQ 9 IRQ 14 IRQ 10 W1 IRQ 1 1 IRQ 12 W2 IRQ 5 IRQ 9 IRQ 7 IRQ 10 IRQ 1 1 IRQ 12 IRQ 14 IRQ 15 Ziatech WinSystems Figure 2-5. Interrupt Jumper Setting for [...]
-
Page 26
Chapter 2 Hardware Configuration and Installation © National Instruments Corp. 2 -11 STD-GPIB for Windows Figure 2-6 shows the setting for IRQ5 in a WinSystems AT-compatible computer. IRQ 5 IRQ 6 IRQ 9 IRQ 14 IRQ 10 W1 IRQ 1 1 IRQ 12 W2 IRQ 5 IRQ 9 IRQ 7 IRQ 10 IRQ 1 1 IRQ 12 IRQ 14 IRQ 15 Ziatech WinSystems Figure 2-6. Interrupt Jumper Setting fo[...]
-
Page 27
Hardware Configuration and Installation Chapter 2 STD-GPIB for Windows 2 -12 © National Instruments Corp. IRQ 5 IRQ 6 IRQ 9 IRQ 14 IRQ 10 W1 IRQ 1 1 IRQ 12 W2 IRQ 5 IRQ 9 IRQ 7 IRQ 10 IRQ 1 1 IRQ 12 IRQ 14 IRQ 15 Ziatech WinSystems Figure 2-7. Jumper Setting for Disabling Interrupts 4 . Record your new setting on the S TD -GPIB Hardware and Softwa[...]
-
Page 28
Chapter 2 Hardware Configuration and Installation © National Instruments Corp. 2 -13 STD-GPIB for Windows 1 . Choose a new DMA channel setting. You can use channel 5 or 6. If you are installing more than one STD-GPIB, each module must either use a unique DMA channel or must not use DMA at all. 2 . Locate the jumpers at W3 that select the DMA chann[...]
-
Page 29
Hardware Configuration and Installation Chapter 2 STD-GPIB for Windows 2 -14 © National Instruments Corp. Using Programmed I/O for GPIB Transfers As an alternative to DMA transfers, you can use programmed I/O. To use programmed I/O, you should disable DMA for the STD-GPIB by moving the jumpers as shown in Figure 2 -9 . DRQ 6 W3 DACK 6 DACK 5 DRQ 5[...]
-
Page 30
Chapter 2 Hardware Configuration and Installation © National Instruments Corp. 2 -15 STD-GPIB for Windows Logic Ground Connected to Shield Ground (Default) Logic Ground Disconnected from Shield Ground W4 W4 Figure 2-10. Ground Configuration Jumper Settings 3 . Record the jumper setting on the STD -GPIB Hardware and Software Configuration Form in A[...]
-
Page 31
Hardware Configuration and Installation Chapter 2 STD-GPIB for Windows 2 -16 © National Instruments Corp. 3 . Record the jumper setting on the STD -GPIB Hardware and Software Configuration Form in Appendix C, Customer Communication . Now that you have properly configured the hardware, return to the Install the Hardware section at the beginning of [...]
-
Page 32
© National Instruments Corp. 3 -1 STD-GPIB for Windows Chapter 3 Software Installation and Configuration This chapter contains instructions to help you install and configure your NI -488.2 software. NI-488.2 Software Components The STD-GPIB is functionally equivalent to the AT-GPIB/TNT and is packaged with the NI-488.2 software for the AT-GPIB/TNT[...]
-
Page 33
Software Installation and Configuration Chapter 3 STD-GPIB for Windows 3 -2 © National Instruments Corp. The software installation begins with the following screen: The interactive Windows setup program takes you through the necessary steps to install the NI-488.2 software. For help during the installation, press the Help button. You can exit the [...]
-
Page 34
Chapter 3 Software Installation and Configuration © National Instruments Corp. 3 -3 STD-GPIB for Windows To run the GPIB software configuration utility, double-click on the GPIB icon in the Control Panel , which is located in the Main group of the Program Manager . The utility displays a list of all the GPIB modules and device names. Double-click [...]
-
Page 35
© National Instruments Corp. 4 -1 STD-GPIB for Windows Chapter 4 Installation Verification and Troubleshooting This chapter describes how to verify the hardware and software installation and how to troubleshoot problems. Troubleshooting ni-pnp Error Messages The ni-pnp.exe program should be located in the root directory of your boot drive, usually[...]
-
Page 36
Installation Verification and Troubleshooting Chapter 4 STD-GPIB for Windows 4 -2 © National Instruments Corp. n i -pnp excludes that I/O port from future testing. If you know that you do not have any National Instruments Plug and Play modules in your system, you can configure n i -pnp so that it does not attempt to detect any Plug and Play module[...]
-
Page 37
Chapter 4 Installation Verifica tion and Troubleshooting © National Instruments Corp. 4 -3 STD-GPIB for Windows Correcting Hardware Settings Follow these steps to troubleshoot Hardware Diagnostic Test error messages. 1 . Make sure you are using a valid base I/O address. Run the Hardware Diagnostic Test again. When it prompts you for values, enter [...]
-
Page 38
Installation Verification and Troubleshooting Chapter 4 STD-GPIB for Windows 4 -4 © National Instruments Corp. 3 . Make sure you are using a valid DMA channel. Run the Hardware Diagnostic Test again. When it prompts you for values, enter the valid base I/O address and interrupt request line as determined in Steps 1 and 2, and enter the current DMA[...]
-
Page 39
Chapter 4 Installation Verifica tion and Troubleshooting © National Instruments Corp. 4 -5 STD-GPIB for Windows Presence Test of Software Components The Software Diagnostic Test checks for the presence of ni-pnp.ini , gpib.ini and gpib.dll . If the ni-pnp.ini file is not found in the root of the boot drive, the following error message is displayed[...]
-
Page 40
Installation Verification and Troubleshooting Chapter 4 STD-GPIB for Windows 4 -6 © National Instruments Corp. If this message appears, you could have one of the following situations: • The module might not be properly configured. Run the GPIB software configuration utility to verify the hardware settings. Refer to the Configure the Hardware sec[...]
-
Page 41
Chapter 4 Installation Verifica tion and Troubleshooting © National Instruments Corp. 4 -7 STD-GPIB for Windows What should I do if one of the diagnostic tests fails with an error? Refer to the troubleshooting sections of this chapter for specific information about what might cause these tests to fail. When should I use the Win16 Interactive Contr[...]
-
Page 42
© National Instruments Corp. 5 -1 STD-GPIB for Windows Chapter 5 Using Your NI-488.2 Software This chapter introduces the Win16 Interactive Control utility and lists some programming considerations. Introduction to the Win16 Interactive Control Utility You can use the interactive control utility to enter NI -488 functions and NI-488.2 routines int[...]
-
Page 43
© National Instruments Corp. A -1 STD-GPIB for Windows Appendix A Hardware Specifications This appendix describes the characteristics of the STD-GPIB and the recommended operating conditions. Table A-1. Electrical Characteristics Characteristic Specification Maximum GPIB Transfer Rate 3-Wire (IEEE 488) High Speed (HS488) Over 1 Mbyte/s* Over 1 Mby[...]
-
Page 44
© National Instruments Corp. B -1 STD-GPIB for Windows Appendix B Interrupt Routing This appendix contains useful information for you if you want to configure the interrupt lines for an STD/STD32 computer not manufactured by WinSystems or Ziatech, or a computer that is not AT-compatible. The STD-GPIB can assert interrupts using one of 10 interrupt[...]
-
Page 45
Interrupt Routing Appendix B STD-GPIB for Windows B -2 © National Instruments Corp. Backplane Interrupts The five STD bus interrupts are INTRQ* (P44), INTRQ1* (P37), INTRQ2* (P50), INTRQ3* (E67), and INTRQ4* (P6). All five interrupts are supported in an STD32 backplane and all but INTRQ3* are supported in an STD-80 backplane. These interrupts are [...]
-
Page 46
© National Instruments Corp. C - 1 STD-GPIB for Windows Appendix C Customer Communication For your convenience, this section contains forms to help you gather the information necessary to help us solve technical problems you might have as well as a form you can use to comment on the product documentation. Filling out a copy of the Technical Suppor[...]
-
Page 47
Technical Support Form Photocopy this form and update it each time you make changes to your software or hardware, and use the completed copy of this form as a reference for your current configuration. Completing this form accurately before contacting National Instruments for technical support helps our applications engineers answer your questions m[...]
-
Page 48
The problem is List any error messages The following steps will reproduce the problem[...]
-
Page 49
STD-GPIB Hardware and Software Configuration Form Record the settings and revisions of your hardware and software on the line to the right of each item. Update this form each time you revise your software or hardware configuration, and use this form as a reference for your current configuration. National Instruments Products • STD-GPIB Model (16-[...]
-
Page 50
• Application Programming Language (Microsoft C, Visual Basic for Windows) • Other Modules in System • Base I/O Addresses of Other Modules • Interrupt Levels of Other Modules • DMA Channels of Other Modules[...]
-
Page 51
Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products. This information helps us provide quality products to meet your needs. Title: Getting Started with Your STD-GPIB and the NI-488.2 ™ Software for Windows Edition Date: December 1995 Part Number: 321042A-01 Please comment on th[...]
-
Page 52
If you find errors in the manual, please record the page numbers and describe the errors. Thank you for your help. Name Title Company Address Phone ( ) Mail to: Technical Publications National Instruments Corporation 6504 Bridge Point Parkway, MS 53-02 Austin, TX 78730-5039 Fax to: Technical Publications National Instruments Corporation MS 53-02 (5[...]
-
Page 53
© National Instruments Corp. G - 1 STD-GPIB for Windows Glossary Prefix Meaning Value m- c- k- M- milli- centi- kilo- mega- 10 -3 10 -2 10 3 10 6 ° degrees % percent A amperes ANSI American National Standards Institute ASIC application-specific integrated circuit C Celsius CP U central processing unit DM A direct memory access EISA Extended Indus[...]