National Instruments cFP-RTD-124 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of National Instruments cFP-RTD-124, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of National Instruments cFP-RTD-124 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of National Instruments cFP-RTD-124. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of National Instruments cFP-RTD-124 should contain:
- informations concerning technical data of National Instruments cFP-RTD-124
- name of the manufacturer and a year of construction of the National Instruments cFP-RTD-124 item
- rules of operation, control and maintenance of the National Instruments cFP-RTD-124 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of National Instruments cFP-RTD-124 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of National Instruments cFP-RTD-124, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the National Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of National Instruments cFP-RTD-124.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the National Instruments cFP-RTD-124 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    323349A-01 October 2002 © 2002 National I nstruments Corp. Al l rights res erved. FieldPoint™, Nati onal Instruments™, NI™, and ni.com™ are trademarks of National Instruments Corpo ration. Product and company names ment ioned herein are trademark s or trade names of their respecti ve companies. For patents covering National Inst ruments pr[...]

  • Page 2

    FP-RTD-124 and cFP-RTD-124 2 ni.com Installing the FP-R TD-124 The FP - R TD-124 m o unts on a FieldPoint terminal base (FP - TB - x ). Hot plug-and-play enables you to install the FP-R TD-124 onto a powered terminal base without disturbing the operation of other modules or terminal bases. The FP-R TD-124 receiv es operating power from the terminal[...]

  • Page 3

    © National Instruments Corp. 3 FP-RTD-124 and cFP-RTD-124 T o install the cFP-R TD-124, refer to Figure 2 and complete the follow ing steps: 1. Align the capti ve scre ws on the cFP-R TD-124 with the holes on the backplane. The alignment keys on the cFP-R TD-124 pre vent backward insertion. 2. Press firmly to seat the cFP-R TD-124 on the backplane[...]

  • Page 4

    FP-RTD-124 and cFP-RTD-124 4 ni.com Wiring the [c]FP-R TD-124 The FP-TB- x terminal bases h av e connectio ns for each of the eig ht input channels on the FP-R TD- 124. The cFP-CB- x connector blocks provide the same connections for the cFP-R TD-124. T able 1 lists the terminal assignments for the signals associated with each channel. If you are us[...]

  • Page 5

    © National Instruments Corp. 5 FP-RTD-124 and cFP-RTD-124 Figure 3 sho ws the input circuitr y on one channel. Figure 3. FP-R TD-124 Input Cir cuit T aking Measurements from Four -Wire RTDs Four -wire R TDs generally hav e two wires of one color and tw o of another color (usually red and white). Connect the wires of one color to the positi v e ter[...]

  • Page 6

    FP-RTD-124 and cFP-RTD-124 6 ni.com negati ve terminals (COM and SENSE – ). Connect the third wire to the positi ve termi nal (SENSE+). Use a short jumper wire to connect the EXCITE+ terminal to the SENSE+ terminal. Figure 5. Three-Wire R TD Connections on One Channel T aking Measurements from T wo-Wire RTDs Connect one wire of a two-wire R TD to[...]

  • Page 7

    © National Instruments Corp. 7 FP-RTD-124 and cFP-RTD-124 Measuring Resistance Y ou can use the [c]FP-R TD-124 to measure resistance in ohms. In this way , you can take measurements from R TDs of types that the [c]FP-R TD-124 does not directly support (such as 120 Ω nick el R TDs) and from resistiv e devices oth er than R TDs. Y ou can measure r[...]

  • Page 8

    FP-RTD-124 and cFP-RTD-124 8 ni.com Unfortunately , not all TCR values are as well def ined b y standards organ izations, and the behavio r of R TDs with the same TCR value may vary from vendor to v endor . The va riations are usually small, and the built-in linearization algorithms of the [c]FP-R TD-124 are appropriate for nearly all applications.[...]

  • Page 9

    © National Instruments Corp. 9 FP-RTD-124 and cFP-RTD-124 Effects of Lead Resistance The [c]FP-R TD-124 measures resistance by driving a current through a circuit and sensing the resulting voltage. An y resistance in the lead wires that connect to the R TD can add errors to your readings if the measured voltage includes the drop across these wires[...]

  • Page 10

    FP-RTD-124 and cFP-RTD-124 10 ni.com connections are isolated from the backplane and the inter-module communication bus. The isolation is provided b y the module, which has optical and galvanic isolation barriers designed and tested to protect against transient fault v oltages of up to 2,300 V rms . Follo w these gui delines to ensure a safe total [...]

  • Page 11

    © National Instruments Corp. 11 FP-RTD-124 and cFP-RTD-124 Specifications These specif ications are typical fo r the range – 40 to 70 ° C unless otherwise noted. Input Characteristic s Number of channels ..................... ..... 8 ADC resolution . ........... ............. ........ 16 bits T ype of ADC ....... ........... ........... .......[...]

  • Page 12

    FP-RTD-124 and cFP-RTD-124 12 ni.com Physical Characteristics Indicators ............ ......... ........... .......... Green POWER and READY indicators W eight FP-R TD-124 ........ ............. .......... 140 g (4.8 oz) cFP-R TD-124 ... ............ ............. . 110 g (3.7 oz) Power Requirements Power from network module ............ 350 mW Iso[...]

  • Page 13

    © National Instruments Corp. 13 FP-RTD-124 and cFP-RTD-124 Safety The [c]FP-R TD-124 is designed to meet the requirements of the follow ing standards for safety and electrical equipment for measurement, control, and laboratory use. • EN 61010-1, IEC 61010-1 • UL 3121-1 • CAN/CSA C22.2 No. 1010.1 For certif ications under re gulatory standard[...]

  • Page 14

    FP-RTD-124 and cFP-RTD-124 14 ni.com Mechanical Dimensions Figure 7 sho ws the mechanical dimen sions of the FP-R TD-124 installed on a terminal base. Dimensions are gi ven in millimeters [inches]. If you are using the cFP-R TD-124, refer to the Compact FieldPoint controller user manual for the dimensions and cabling clearance requirements of the C[...]

  • Page 15

    © National Instruments Corp. 15 FP-RTD-124 and cFP-RTD-124 Finland 09 725 725 11, France 01 48 14 24 24, Germany 089 741 31 30, Greece 01 42 96 427, Hong K ong 2645 3186, In dia 91 80 4190000, Israel 03 6393737, Italy 02 41 3091, Japan 03 5472 2970, K orea 02 3451 3400, Malay sia 603 9596711, Mexico 001 800 010 0793, Netherlands 0348 433466, New Z[...]