National Instruments Isolated Analog Input Modules SCC-AI01 manual
- Read online or download the manual
- 18 pages
- 0.21 mb
Go to page of
Similar user manuals
-
Network Card
National Instruments CFP-CTR-502
22 pages 0.44 mb -
Network Card
National Instruments USB Digitizers NI USB-5132
9 pages 0.46 mb -
Network Card
National Instruments RT Series
36 pages 0.35 mb -
Network Card
National Instruments NI WLS/ENET-9163
36 pages 1.25 mb -
Network Card
National Instruments USB-9201
16 pages 0.45 mb -
Network Card
National Instruments Quadrature Input Module FP-QUAD-510
12 pages 0.17 mb -
Network Card
National Instruments NI USB-9234
23 pages 0.6 mb -
Network Card
National Instruments NI 9144
65 pages 1.69 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of National Instruments Isolated Analog Input Modules SCC-AI01, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of National Instruments Isolated Analog Input Modules SCC-AI01 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of National Instruments Isolated Analog Input Modules SCC-AI01. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of National Instruments Isolated Analog Input Modules SCC-AI01 should contain:
- informations concerning technical data of National Instruments Isolated Analog Input Modules SCC-AI01
- name of the manufacturer and a year of construction of the National Instruments Isolated Analog Input Modules SCC-AI01 item
- rules of operation, control and maintenance of the National Instruments Isolated Analog Input Modules SCC-AI01 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of National Instruments Isolated Analog Input Modules SCC-AI01 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of National Instruments Isolated Analog Input Modules SCC-AI01, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the National Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of National Instruments Isolated Analog Input Modules SCC-AI01.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the National Instruments Isolated Analog Input Modules SCC-AI01 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
USER GUIDE SCC-AI Series Isolated Analog Input Modules The SCC-AI Series isolated analog input modules (SCC-AI XX ) can extract a relativ ely low-amplitude input signal from a high-commo n-mode voltage so the E Series D A Q de vice can measure the input sig nal. They also can amplify and filter the input signal, resulting in hig her measurement res[...]
-
Page 2
SCC-AI Series Isolated Analog Input Modules 2 ni.com Conventions The follo wing con ventions are used in this guide: < > Angle brackets that contain numbers separated by an ellipsis represent a range of v alues associated with a bit or signal name—for e xample, ai<0..7>. This icon denotes a note, which alerts you to important inform a[...]
-
Page 3
© National Instruments Corporation 3 SCC-AI Series Isolated Analog Input Modules ❑ One or more SCC-SG XX ❑ SCC-SG Series Strai n-Gauge Modules User Guide ❑ SC-2345 User Manual ❑ Read Me Fir st: Safety and Ra dio-Frequency Interference ❑ SC-2345 Q uick Reference L abel ❑ 68-pin Basic or E Series D A Q device, d ocumentation, and 68-pin [...]
-
Page 4
SCC-AI Series Isolated Analog Input Modules 4 ni.com Installing the Module Caution R efer to the Read Me First: Sa fety and Radio-F requency Interf erence document before remo ving equipment co vers or connectin g/disconnect ing any si gnal wires A blue label stripe identifies the SCC- AI XX as an an alog input m odule. The label al so displays the[...]
-
Page 5
© National Instruments Corporation 5 SCC-AI Series Isolated Analog Input Modules Connecting the Input Signals The SCC- AI XX has a f ixed scre w-terminal receptacle and a remo vabl e scre w-terminal block, as sho wn in F igure 1-2. Figur e 1-2. SCC-AI XX T wo-Part Screw-T erminal System After you install the SCC- AI XX , connect the input signals [...]
-
Page 6
SCC-AI Series Isolated Analog Input Modules 6 ni.com Figu re 1-3. SCC-AI XX Signal Co nnecti ons The input s are designed in a floating (no nreferenced) singl e-ended conf iguration. If the measured signals are floating, con nect the negati ve input pin s, 1 and 3, to AISENSE on the SC-2345 te rminal block through a1 0k Ω to 100 k Ω resistor. F[...]
-
Page 7
© National Instruments Corporation 7 SCC-AI Series Isolated Analog Input Modules If a high commo n-mode v oltage is present, conn ect the negati ve input pins, 1 and 3, t o the signal r eference. Figure 1-5 sh ows a ground-r eferenced signal co nnection on on e channel of t he SCC-AI XX . Figu re 1-5. Ground-Ref erenced Sign al Connection for t he[...]
-
Page 8
SCC-AI Series Isolated Analog Input Modules 8 ni.com 4. In th e SCC Connecto r Block Configuration window , configure the SCC syst em as follows: a. Specify the SCC Carrier T ype . The location of the SCC sockets change depen ding on the S CC carrier type. b . Select the DAQ D e v i c e that is connected to the SC-2345. c. T ype the SCC Connector B[...]
-
Page 9
© National Instruments Corporation 9 SCC-AI Series Isolated Analog Input Modules 10. If you mak e a selection mistak e, select the socket and click Remove . 11. Repeat steps 8 an d 9 for each ne wly installed SCC. 12. Clic k OK after completing all SCC entries. 13. Clic k OK to complete the conf iguration proces s and close MAX. Note Configuring t[...]
-
Page 10
SCC-AI Series Isolated Analog Input Modules 10 ni.com T ab le 1-2 shows su ggested values for some o f the par ameters. Use d efault v alues for parameters not s hown. 9. Clic k Te s t to test the channel. Y ou should be ab le to vie w your measurement in the window that ap pears. Y ou hav e finis hed confi guring the N I-D A Qmx task or g lobal ch[...]
-
Page 11
© National Instruments Corporation 11 SCC-AI Series Isolated Analog Input Modules Scal ing V oltage Me asur ement s If you c onf igured the S CC-AI XX using MAX and you are using NI-D A Q, the vo ltage reading you get from the E Series D A Q de vice accounts for the vo ltage scaling effect of the SCC-AI XX . Otherwise, since the v oltage measureme[...]
-
Page 12
SCC-AI Series Isolated Analog Input Modules 12 ni.com Filter Characte ristics Number of poles ......... ...................... ......3 Rolloff ................... ................. .................60 dB/decade Cutoff freq uency (–3 dB) AI0 X ......... ................ ................. ......10 kHz AI1 X ......... ................ ..............[...]
-
Page 13
© National Instruments Corporation 13 SCC-AI Series Isolated Analog Input Modules Environment al Operating temperature........ ................. ... 0 to 50 ° C Storage temperature ............................ ... –20 to 70 ° C Humidity ................. ................. .............. 10 to 90% RH, noncondens ing Maximum altitude ...........[...]
-
Page 14
SCC-AI Series Isolated Analog Input Modules 14 ni.com Calibrating Gain and Offset Errors The SCC-AI XX is cal ibrated at the factory b efore shipmen t. If you want to adjust the gain of the SCC-AI XX in your sy stem using you r E Series D A Q de vice, you need a v oltage source that is sev eral times more accurate than the SCC it self and capable o[...]
-
Page 15
© National Instruments Corporation 15 SCC-AI Series Isolated Analog Input Modules 9. Adjust the trimp ot labeled Gain located on the top of the SCC-AI XX . If the v alue you obtained in step 8 is less than the input voltage, turn the trimpot clockwise to increase the g a in. If it is greater th an the input vo ltage, turn the trimpot counterc lock[...]
-
Page 16
SCC-AI Series Isolated Analog Input Modules 16 ni.com SCC-AI XX Module Pin Assignments Figure 1-6 shows the I/O connect or pins on the bottom of t he module. Figur e 1-6. SCC Module Bottom View T able 1-4 lists the sig nal correspondi ng to each I/O connector pin o n the bottom of the SCC-AI XX . A CH( X ) and A CH( X + 8) are the analog input chan[...]
-
Page 17
© National Instruments Corporation 17 SCC-AI Series Isolated Analog Input Modules 9 + 6 V 10 GND 11 AG N D 12 REF5V 13 + 15 V 14 –15 V 15 — 16 — 17 — 18 — 19 — 20 — Tabl e 1-4. SCC-AI XX Module Pi n Assig nments ( Con tinued ) Pin Number Signal[...]
-
Page 18
National Instrument s™, NI™, ni.com ™, and NI-D AQ ™ are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering Na tiona l Instruments products, refer to the appropriate location: Help»Patents i n yo ur sof twa re , th e pa[...]