Go to page of
Similar user manuals
-
Network Card
National Instruments NI PXI-8104
69 pages 2.22 mb -
Network Card
National Instruments Gigabit Ethernet Adapters
17 pages 0.96 mb -
Network Card
National Instruments CFP-2220
38 pages 4.73 mb -
Network Card
National Instruments NI PCIe-8255R
16 pages 0.27 mb -
Network Card
National Instruments NI 6013
109 pages 0.81 mb -
Network Card
National Instruments Module SCXI-1503
79 pages 1.09 mb -
Network Card
National Instruments NI PXI-7831R
73 pages 0.68 mb -
Network Card
National Instruments Network Adapter NI PXIe-1075
78 pages 7.8 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of National Instruments Module NI PXI-8250, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of National Instruments Module NI PXI-8250 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of National Instruments Module NI PXI-8250. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of National Instruments Module NI PXI-8250 should contain:
- informations concerning technical data of National Instruments Module NI PXI-8250
- name of the manufacturer and a year of construction of the National Instruments Module NI PXI-8250 item
- rules of operation, control and maintenance of the National Instruments Module NI PXI-8250 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of National Instruments Module NI PXI-8250 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of National Instruments Module NI PXI-8250, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the National Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of National Instruments Module NI PXI-8250.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the National Instruments Module NI PXI-8250 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
PXI NI PXI-8250 User Manual National Instruments S ystem Monitor Hardware NI PXI-8250 User Manual July 2008 372605A-01[...]
-
Page 2
Support Worldwide Technical Support and Product Info rmation ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Aust in, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide Offices Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800,[...]
-
Page 3
Important Information Warranty The NI PXI-8250 is warranted agai nst defects in materials and workmanshi p for a period of on e year from the date of sh ipment, a s evidenced by receipts or other documentati on. National Instruments wil l, at its option, repair or replace equipment that proves to be defect ive during the warranty period. This warra[...]
-
Page 4
© National Instruments Corpor ation v NI PXI-8250 User Manual Contents About This Manual Conventions ............ .............. .............. .............. .............. .............. ............... .............. .... v ii Related Documentation ............ .............. .............. .............. .............. ................. ......[...]
-
Page 5
Contents NI PXI-8250 User Manual vi ni.com Appendix B Technical Support and Professional Services Glossary Index[...]
-
Page 6
© National Instruments Corporat ion vii NI PXI-8250 User Manual About This Manual The NI PXI-8250 User Manual describes the features of the NI PX I-8250, and contains information about configuring and operatin g the hardware. Conventions The follo wing con ventions are used in this manual: » The » symbol leads you through nested menu items and d[...]
-
Page 7
About This Manual NI PXI-8250 User Manual viii ni.com Related Documentation The following documents contain information that you mi ght find helpful as you read this manual: • IEEE 1101.1-1991, IEEE Standard for Mecha nical Core Specifications for Microcomputers Using IEC 603-2 Con nectors • IEEE 1101.10, IEEE Standard for Addi tional Mechanica[...]
-
Page 8
© National Instruments Corporat ion 1-1 NI PXI-8250 User Manual 1 Getting Started This chapter includes information a bout the features of the NI PXI-8250 and information about operati ng the hardware. About the NI PXI-8250 Module The NI PXI-8250 module monitors the status parame ters of a chassis and displays the status information with front pan[...]
-
Page 9
Chapter 1 Getting Started NI PXI-8250 User Manual 1-2 ni.com What Y ou Need to Get Started To set up and use the NI PXI-8250 module, you must have the followin g items: ❑ An NI PXI-8250 System Monitor module ❑ An NI PXI-1042, NI PXI-1042Q, or NI PXI-1045 chassis ❑ This manual ❑ Optional: The NI System Monitor 1.1 driv er software and docume[...]
-
Page 10
Chapter 1 Getting Started © National Instruments Corporat ion 1-3 NI PXI-8250 User Manual If you need to clean the de vice, use a soft, nonmetallic brush. Make sure that the device is completely dry and free from contaminants before returnin g it to service. Operate the device only at or belo w Pollution Degree 2. Pollution is foreign matter in a [...]
-
Page 11
Chapter 1 Getting Started NI PXI-8250 User Manual 1-4 ni.com equipment, circuits powered by regulated lo w-voltage sources, and electronics. • Installation Category II is for measurements performed on ci rcuits directly connected to the electrical dist ribution system. This category refers to local-le vel elect rical distribution, such as that pr[...]
-
Page 12
© National Instruments Corporat ion 2-1 NI PXI-8250 User Manual 2 Configuration and Installation This chapter describes how to configure and inst all the NI PXI-8250. Software Installation Before installing the NI PXI-8250, install the NI System Monitor driver software. Refer to the NI Syst em Monito r 1.1 Help for specific installation instructio[...]
-
Page 13
Chapter 2 Configur ation and Installation NI PXI-8250 User Manual 2-2 ni.com The NI PXI-8250 is a sensiti ve electronic de vice sh ipped in an antistatic bag. Open only at an approv ed workstation and observ e precautions for handling elect ros tatic-sensitiv e devices. Note Install the NI PXI-8250 in only the right-most slot of an NI PXI-1042/1042[...]
-
Page 14
Chapter 2 Configurati on and Installation © National Instruments Corporat ion 2-3 NI PXI-8250 User Manual Figure 2-1. Location of NI PXI-1042Q Slot for NI PXI-8250 Support NI PXI-1042Q Slot 8[...]
-
Page 15
Chapter 2 Configur ation and Installation NI PXI-8250 User Manual 2-4 ni.com Figure 2-2. Location of NI PXI-1045 Slot for NI PXI-8250 Support 3. T ouch a metal part on the chassis to discharge any static electricity that might be on y our clothes or b ody . Static electricity can dam age the hardware. 4. Insert the NI PXI-8250 module into the rig h[...]
-
Page 16
Chapter 2 Configurati on and Installation © National Instruments Corporat ion 2-5 NI PXI-8250 User Manual 9. Allo w the operating system to pr operly detect and identify the NI PXI-8250 module. 10. Launch W indo ws De vice Manager and refresh the view . The NI PXI-8250 module should be visible in Windo ws De vice Manager . NI PXI-8250 Configuratio[...]
-
Page 17
© National Instruments Corporat ion 3-1 NI PXI-8250 User Manual 3 Hardware Over view This chapter presents an ov erview of the NI PXI-8250 functionality . Figure 3-1, Figure 3-2, and Figure 3-3 sh ow the locations of k ey features for the NI PXI-8250 module. Figure 3-1. NI PXI-8250 Parts Locator Diagram 1 Assembly Part Number Label 2 S erial Numbe[...]
-
Page 18
Chapter 3 Hardware Over view NI PXI-8250 User Manual 3-2 ni.com Figure 3-2. NI PXI-8250 Front Panel Diagram Figure 3-3. Symbols on the Back of the NI PXI-8250 1 S ystem S tatus LEDs 2U s e r L E D s 3 Front Panel Connector (Relay/Power Outputs) 1 Identification Number Used in Australia 2 S ymbol Indicating FFC Compliance 3 S ymbol to Alert User to [...]
-
Page 19
Chapter 3 Hardware Over view © National Instruments Corporat ion 3-3 NI PXI-8250 User Manual System Monitoring Architecture With the NI PXI-8250, you can simultaneously monitor int ake temperature, fan speeds, and power su ppl y levels of your NI PXI chassis. This information allows the user to achieve a higher level of system performance reliabil[...]
-
Page 20
Chapter 3 Hardware Over view NI PXI-8250 User Manual 3-4 ni.com Fan Monitoring The NI PXI-8250 module allows the user to monitor the revolutions per minute (RPM) of all rear-facing fans of a PXI chassis (two fans in an NI PXI-1042/1042Q and three fans in an NI PXI-1045), accurate to ±50 R PM. The fan data fr om the chassis is interp reted by the N[...]
-
Page 21
Chapter 3 Hardware Over view © National Instruments Corporat ion 3-5 NI PXI-8250 User Manual System Status LEDs There are 6 system status LEDs to repo rt the status of the +5 V, +3.3 V, +12 V, and –12 V pow er rails, the intake temperature of th e chassis, and the overall status of the power shuttle fa ns of the chassis. These LEDs only light up[...]
-
Page 22
Chapter 3 Hardware Over view NI PXI-8250 User Manual 3-6 ni.com Figure 3-5 shows the layout of this connector . Figure 3-5. NI PXI-8250 Front Panel Connector Pinout Diagram Figure 3-6. NI PXI-8250 Relay Operation Diagram 1 Alert Relay Terminal Pins 2 Fused Power Output Terminal Pins 1 2 NO (Normally Open) COM (Common) NC (Normally Closed) 5V 3.3V 1[...]
-
Page 23
Chapter 3 Hardware Over view © National Instruments Corporat ion 3-7 NI PXI-8250 User Manual Alert Relay Pins The NI PXI-8250 has an el ectromechanical non-latch ing relay with three ports: normally open (NO), normall y closed (NC), and common (COM). The top three pins of the front panel connector are connected to a relay as indicated in Figure 3 [...]
-
Page 24
Chapter 3 Hardware Over view NI PXI-8250 User Manual 3-8 ni.com The NI PXI-8250 has self-resetting fu ses rated at 1 A/125 V on the front end and one-blow fuses rated at 4 A/1 25 V on the back end of the card to protect the card from excessive curren t draw. Refer to Figure 3-1 for the locations of these fuses. When current is exceeded on any of th[...]
-
Page 25
© National Instruments Corporat ion A-1 NI PXI-8250 User Manual A Specifications This appendix lists the hardware a nd software performance specifications for the PXI-8250. Hard ware specifica tions are typical at 25 °C, unless otherwise stated. Caution Specifications are subject to change without notice. Maximum Power Requir ements Without power[...]
-
Page 26
Appendix A Specifications NI PXI-8250 User Manual A-2 ni.com Monitoring Alert Limi ts (Green Status LEDs) Voltage rail level ............. .............. .........±5% (from nominal) Intake temperature ...................... ............0 –50 °C Fan speed ................... .............. .............. .1,500 RPM or more for all fans in a chas[...]
-
Page 27
Appendix A Specifications © National Instruments Corporat ion A-3 NI PXI-8250 User Manual Operating Environment Ambient temperature range .................... 0 to 55 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) Relative humidi[...]
-
Page 28
Appendix A Specifications NI PXI-8250 User Manual A-4 ni.com Safety This product meets the requirements of the follow ing standards of safety for electrical equipment for measurement, contro l, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certifications , refer to the product label or th e[...]
-
Page 29
Appendix A Specifications © National Instruments Corporat ion A-5 NI PXI-8250 User Manual Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible man ner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For[...]
-
Page 30
© National Instruments Corporat ion B-1 NI PXI-8250 User Manual B T echnical Support and Professional Ser vices Visit the following sections of the award-winning National Instruments Web site at ni.com for technical support and professional services: • Support —T echnical support resou rces at ni.com/support include the following: – Self-Hel[...]
-
Page 31
Appendix B T echnical Support and Professional Ser vices NI PXI-8250 User Manual B-2 ni.com • Declaration of Conformit y (DoC) —A DoC is our claim of compliance with the C ouncil of the European Communities usin g the manufacturer’ s declaration of conformity . This system affords the user protection f or electromagnetic compatibility ( EMC) [...]
-
Page 32
© National Instruments Corporat ion G-1 NI PXI-8250 User Manual Glossar y Symbol Pref ix V alue pp i c o 1 0 –1 2 nn a n o 1 0 –9 μ micro 10 –6 m milli 10 –3 k kilo 10 3 Mm e g a 1 0 6 Gg i g a 1 0 9 Tt e r a 1 0 12 Numbers/Symbols ° degrees /p e r % percent ± plus or minus +5 V +5 VDC source signal +3.3 V +3.3 VDC source signal +12 V +[...]
-
Page 33
Glossary NI PXI-8250 User Manual G- 2 ni.com API application programming interface B backplane An assembly , typically a printed circuit board, with con nectors and signal paths that bus the connector pins. C CC e l s i u s CFR Code of Federal Regulations cm Centimeters COM A common terminal of the relay that either connects to NO or NC. See also N[...]
-
Page 34
Glossary © National Instruments Corporat ion G-3 NI PXI-8250 User Manual E electromechanical relay Electromechanical relay made of a coil, an armature mechanism, and electrical contacts. When the coil is ener gized, the induced magnetic f ield mov es the armature that opens or closes the c ontacts. EMC Electromagnetic Comp atibility F FCC Federal [...]
-
Page 35
Glossary NI PXI-8250 User Manual G- 4 ni.com L LED Light-Emitt ing Diode M m meters MAX Measurement & Automation Explor er—A controlled, centralized configuration en v ironment that allows you to configure all of your NI de vices. ms milliseconds N NI National Instruments NO The normally-open terminal of a rela y that connects to the common ([...]
-
Page 36
Glossary © National Instruments Corporat ion G-5 NI PXI-8250 User Manual R RMS Root Mean Square RPM rev olutions per minute—unit s for velocity S s seconds self-resetting fuse A fuse that acts as an open circuit only when curr ent is overdra wn. Once the overdra w ends the fuse returns to normal closed circuit operation. system controller A modu[...]
-
Page 37
© National Instruments Corporat ion I-1 NI PXI-8250 User Manual Index A about the NI PXI-8250, 1-1 accuracy, monitoring, A-2 additional monitori ng features, 3-4 alert limit s, monitoring, A-2 alert relay pins, 3-7 specifications, A-2 architecture, system monitoring, 3-3 C calibration certificate (NI resources), B-2 configuration and installation,[...]
-
Page 38
Index NI PXI-8250 User Manual I-2 ni.com L LEDs front panel, 3-4 system status, 3-5 user, 3-5 M maximum power requir ements with power outputs, A-1 without power outp uts, A-1 monitoring accuracy specifications, A-2 alert limit specifications, A-2 fan, 3-4 temperature, 3-3 voltage rail level, 3-3 N National Instruments support and services, B-1 NI [...]
-
Page 39
Index © National Instruments Corporat ion I-3 NI PXI-8250 User Manual support, technical, B-1 system monitoring, 3-3 status LEDs, 3-5 T technical support, B-1 temperature monitoring, 3-3 training and certificatio n (NI resources), B-1 troubleshooting (NI resources), B-1 U user LEDs, 3-5 V vibration specifications, A-3 voltage rail level monitoring[...]