A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of National Instruments NI 9871, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of National Instruments NI 9871 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of National Instruments NI 9871. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of National Instruments NI 9871 should contain:
- informations concerning technical data of National Instruments NI 9871
- name of the manufacturer and a year of construction of the National Instruments NI 9871 item
- rules of operation, control and maintenance of the National Instruments NI 9871 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of National Instruments NI 9871 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of National Instruments NI 9871, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the National Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of National Instruments NI 9871.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the National Instruments NI 9871 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
OPERATING INSTRUCTIONS AND S PECIFICATIONS NI 9871 4-Port, RS485/RS42 2 Serial Modu le[...]
-
Page 2
NI 9871 Operating Instructions 2 ni.com This document describes how to use the National Instruments 9871 and includes specif icat ions and pin assignments for the NI 9871. Vi s i t ni.com/info and enter rdsoftwareversion to determine which software you need for the modules you are using. F or information about inst alling, conf iguring, and program[...]
-
Page 3
© National Instruments Corp. 3 NI 9871 Operating Instructions Safety Guidelines fo r Hazardous Loca tions The NI 9871 is suitable for use in Cl ass I, Division 2, Groups A, B, C, D, T4 hazardous locations; Clas s I, Zone 2, AEx nA II T4 and Ex nA II T4 hazardous locations ; and nonhazardous locations only . Follo w these guidelines if you ar e ins[...]
-
Page 4
NI 9871 Operating Instructions 4 ni.com Caution For Zone 2 applications, install a protection device between the RS485/RS 422 signal cables and the NI 9871 RJ-50 jacks (p orts 1– 4). The device must prev ent the RS485/RS422 signal-to -signal or signal-to-COM voltage from ex ceeding 23 V if there is a transient overv oltage condition. Caution For [...]
-
Page 5
© National Instruments Corp. 5 NI 9871 Operating Instructions Special Conditions fo r Marine Appli cations Some modules are Lloyd’ s Register (LR) T ype Approved for marine applications. T o verify Llo yd’ s Register cert if ication, visit ni.com/certification and search for the LR certificate, or look for the Lloyd’ s Register mark on th e [...]
-
Page 6
NI 9871 Operating Instructions 6 ni.com Wiring the NI 9871 The NI 9871 has four RJ-50 recep t acles that prov ide connections for four RS485/RS422 de vices. Table 1. RS485/RS422 Po rt Pinout RJ-50 Pin Signal Name* 1 No Connect 2 TXD– 3 TXD+ 4 RT S – 5 CTS– 6 RXD– 7 RXD+ 8 RT S + 9 CTS+ 10 GND * These signals are shared by all four RJ-50 con[...]
-
Page 7
© National Instruments Corp. 7 NI 9871 Operating Instructions The cables included with your kit con vert the RJ-50 pinout to the standard NI pinout, as shown in T able 2. Table 2. Pin Assignments for RS485/RS422 DB-9 Male Connector Connector Pin Signal 1 GND 2 CTS+ 3 RT S + 4 RXD+ 5 RXD– 6 CTS– 7 RT S – 8 TXD+ 9 TXD– 6 7 8 9 1 2 3 4 5[...]
-
Page 8
NI 9871 Operating Instructions 8 ni.com Y ou must connect an external po wer supply to the NI 9871. This power supply p rovides the po wer for the RS485/RS422 transceiv ers on th e module. Y ou can use the included female four-position pigtail to connect to an e xternal vo ltage source. Figure 1 lists the connections bet w een an external v oltage [...]
-
Page 9
© National Instruments Corp. 9 NI 9871 Operating Instructions Figure 2 shows the method of po wer connection to the NI 9871 module. Attach an isolated power supply to the V sup and C OM terminals using the included pigtail. Figure 2. Powering the NI 9871 fr om an Isolated Power Sour ce Figure 3 sho ws ho w to use the optional y-adapter (a v ailabl[...]
-
Page 10
NI 9871 Operating Instructions 10 ni.com additional module. Ensure that the power supply can handle maximum power requirements for all modules connected. Caution All connections must be made before power is applied. Figure 3. Poweri ng Multiple Modules from a Single Power Supp ly Red (+) Black (–) NI P/N 198303-XX: Male Microfit Y -Adapter NI P/N[...]
-
Page 11
© National Instruments Corp. 11 NI 9871 Operating Instructions RS485 Bus T opology and T ermi nation Refer to Figure 4 and Fig ure 5 for an o vervie w of 4-wire and 2-wire RS485 bus topol ogies and termination. Figure 4. 4-Wir e Full-Dupl ex Multidrop Netw ork Using T erminating Resistors Figure 5. 2-Wire Multidrop Network Using T erminating Resis[...]
-
Page 12
NI 9871 Operating Instructions 12 ni.com RS485 T ransceiver Control Refer to T able 3 for a listing of TX and RX enable conditions for the dif ferent RS485 transcei ver contro l modes. NI 9871 Hardware Over view The NI 9871 has four independent RS48 5/RS422 ports that are isolated from the other modules in the system. Each port is fully compatible [...]
-
Page 13
© National Instruments Corp. 13 NI 9871 Operating Instructions Sleep Mode (CompactRIO Only) Y ou can enable sleep mode fo r the CompactRIO system in software. In sleep mode, the syst em consumes less power and may dissipate less heat. T ypically , when a system is in sleep mode, you cannot communicate with th e modules. Refer to the Spec ification[...]
-
Page 14
NI 9871 Operating Instructions 14 ni.com Note Contact NI for Bellcore MTBF specifications at other temperatures or for MIL-HDBK -217F specifications. Power Requirements Power consumption from chassis Active mode ............ ........... ........ 0.5 W max Sleep mode .............. ........... ........ 50 μ W max Thermal dissipation (at 70 °C) Act[...]
-
Page 15
© National Instruments Corp. 15 NI 9871 Operating Instructions Safety Maximum Voltage 1 Connect only v oltages that are within these limits. RS485/RS422 Port-to-COM ........ ..... –8 to +13 VDC max, Measurement Category I V SUP -to-COM .............. ........... ......... . ±28 V max, Measurement Category I Measurement Cate gory I is f or measu[...]
-
Page 16
NI 9871 Operating Instructions 16 ni.com Isolation Voltages Port-to-earth ground W ithstand............... ......... ............ 1000 V rms , ver ifie d by a dielectric withstand test, 5 s Continuous .......... ........... ......... ... 60 VDC, Measurement Category I Hazardous Locations U.S. (UL) ............ ........... ......... .......... Class[...]
-
Page 17
© National Instruments Corp. 17 NI 9871 Operating Instructions Safety Standards The NI 9871 is designed to meet the requirements of the following standards of safety for electric al equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certif ications, refer to [...]
-
Page 18
NI 9871 Operating Instructions 18 ni.com Note For the standards applied to assess the EMC of this product, refer to the Online Product Certification section. Note For EMC compliance, operate this de vice with shielded cabling. CE Compliance This product meets the essentia l requirements of applicable European Directi v es, as amended for CE marking[...]
-
Page 19
© National Instruments Corp. 19 NI 9871 Operating Instructions Shock and Vibration T o meet these spec ifications, you must panel mou nt the CompactRIO system . Operating vibration, random (IEC 60068-2-64) ... ............. 5 g rms , 10 to 500 Hz Operating shock (IEC 60068-2-27)........... ........... ........ 30 g, 11 ms half sine, 50 g, 3 ms hal[...]
-
Page 20
NI 9871 Operating Instructions 20 ni.com Operating humidity ............. ........... ... 10 to 90% RH, noncondensing Storage humid ity ........ ........... ........... . 5 to 95% RH, noncondensing Maximum altitude.......... ......... .......... 2,000 m Pollution Degree (IEC 60664) .......... 2 Environmental Mana gement NI is committed to designing[...]
-
Page 21
© National Instruments Corp. 21 NI 9871 Operating Instructions Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of their lif e cycle, all products must be sent to a WEEE re c ycling center . For more information about WEEE recy cling centers and National Instruments WEEE initi ativ es, visi t ni.com/ environment/weee.htm . [...]
-
Page 22
NI 9871 Operating Instructions 22 ni.com Where to Go for Support The National Instruments W eb site is your complete resource for technical support. At ni.com/support you ha ve access to ev erything from troubleshooting and application de velopment self-help resources to emai l and phone assistance from NI Application Engineers. National Instrument[...]
-
Page 23
© National Instruments Corp. 23 NI 9871 Operating Instructions K orea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710, Mexico 0 1 800 010 0793, Netherlands 31 (0) 348 433 466, New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, Poland 48 22 3390150, Portugal 351 210 311 210, Russia 7 495 783 6851, Singapore 1800 226 5886, Slo v [...]
-
Page 24
© 2007–2008 Nati onal Instruments Corp. All rights reserved. 372277B-01 Sep08 National Instruments, NI, n i.com, and LabVIEW are trademarks of National Instrument s Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instrument s trademarks. Other product and company names ment ioned herein are trad[...]