A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of National Instruments NI PXI-5621, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of National Instruments NI PXI-5621 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of National Instruments NI PXI-5621. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of National Instruments NI PXI-5621 should contain:
- informations concerning technical data of National Instruments NI PXI-5621
- name of the manufacturer and a year of construction of the National Instruments NI PXI-5621 item
- rules of operation, control and maintenance of the National Instruments NI PXI-5621 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of National Instruments NI PXI-5621 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of National Instruments NI PXI-5621, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the National Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of National Instruments NI PXI-5621.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the National Instruments NI PXI-5621 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    © 2002 National Instruments Corp. All rights reserved. National Instruments™, NI™, and ni.com ™ are trademarks of National Instruments Corporation. Product and company names mentioned herein are tradem arks or trade names of their respectiv e companies. For patents covering National Instruments products, refer to the appropriate location: He[...]

  • Page 2

    NI PXI-5621 Specifications 2 ni.com DC offset .............. ............... ........... .........±1 mV (calibrated) Analog bandwidth ( – 3 dB range) .. .........0 Hz to 36 MHz Amplitude accuracy ................................±0.5 dB VSWR 0 – 25 MHz .............. ........... .............. .<1.5:1 25 – 32 MHz .................... ....[...]

  • Page 3

    © National Instruments Corporation 3 NI PXI-5621 Specifications Amplitude Figure 1. Noise Density (Dither Disabled, Input T erminated) A verage noise density (dither off) .................... ........... .............. . < – 129 dBm /Hz Signal-to-noise r atio 9 dBm signal, full bandwidth .......... >62 dB Harmonic distortion (single tone, [...]

  • Page 4

    NI PXI-5621 Specifications 4 ni.com Figure 2. Intermodulation Distortion Intermodulation di stortion (2-tone, 0 dB m signals, 200 kHz sep aration) 4 – 15 MHz, dither enabled ......... ......< – 86 dBm 0 – 32 MHz, dither disabled ..............< – 78 dBm Residual responses (input term inated) ....< – 75 dBm 0.00 – 10.00 – 20.0[...]

  • Page 5

    © National Instruments Corporation 5 NI PXI-5621 Specifications Figure 3. Frequency Response (0.1 – 32 MHz) Frequency response (4 – 25 MHz) Relative (to response at 15 MHz) ... < ±0.25 dB Absolute .... ............... .............. ......... < ±0.6 dB Absolute (using calibration table) ... < ±0.5 dB 0.20 0.10 0.00 – 0.10 – 0.2[...]

  • Page 6

    NI PXI-5621 Specifications 6 ni.com Phase Figure 4. Group Delay versus Frequency Group delay variation (5 – 25 MHz) . .............. .............. ........... ....9 ns pk – pk Group delay variation (0.5 – 30 MHz) ...... ............... ........... .........26 ns pk – pk DDC Decimation rate........................ .............. .32 – 4,0[...]

  • Page 7

    © National Instruments Corporation 7 NI PXI-5621 Specifications T riggering Modes ....... ........... .............. .............. ....... Immediate, software, digital Sources ................... .............. ........... ....... PFI 1, PXI<0..7>, PXI STAR Export ....... .............. .............. ........... ....... PFI 1, PXI<0..7&[...]

  • Page 8

    NI PXI-5621 Specifications 8 ni.com Environmental Specifications Warm-up time ............... ........... .............. .10 minutes Operating environment Ambient temperature ................... ....0 – 50 ° C Humidity .. .............. .............. ........... .10 – 90%, nonco ndensing Storage environment Storage temperature ..... .........[...]

  • Page 9

    © National Instruments Corporation 9 NI PXI-5621 Specifications Electromagnetic Compatibility CE, C-Tick, and FCC Part 15 (Class A) compliant Electrical emissions....................... ......... EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Electrical immunity ......... .............. ......... Evaluated to EN 61326:1997/A1:19 98, Table 1 Not[...]