Go to page of
Similar user manuals
-
Power Supply
National Instruments PXI-1045
7 pages 0.19 mb -
Power Supply
National Instruments PXI-1042
6 pages 0.15 mb -
Power Supply
National Instruments NI PXI-1006
5 pages 0.12 mb -
Power Supply
National Instruments NI PXI-1042 Series
8 pages 0.23 mb -
Power Supply
National Instruments FP-PS-4
11 pages 0.5 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of National Instruments PXI-1042, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of National Instruments PXI-1042 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of National Instruments PXI-1042. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of National Instruments PXI-1042 should contain:
- informations concerning technical data of National Instruments PXI-1042
- name of the manufacturer and a year of construction of the National Instruments PXI-1042 item
- rules of operation, control and maintenance of the National Instruments PXI-1042 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of National Instruments PXI-1042 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of National Instruments PXI-1042, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the National Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of National Instruments PXI-1042.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the National Instruments PXI-1042 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
© 2002 National Instruments Corp. All rights reserved. National Instruments™, NI™, and ni.com ™ are trademarks of National Instruments Corporation. Product and company names mentioned herein are tradem arks or trade names of their respectiv e companies. For patents covering National Instruments products, refer to the appropriate location: He[...]
-
Page 2
NI PXI-1042 Power Supply Shuttle User Guide 2 ni.com What Y ou Need to Get Started ❑ PXI-1042 chassis (the uni t being repaired) ❑ PXI-1042 power supply shuttle ❑ Read Me First: Safety and Radio-Frequency Interference ❑ NI PXI-1042 User Manual (provided with the chassis; also a v ailable at ni.com/support ) ❑ #1 Phillips screwdriv er Desc[...]
-
Page 3
© National Instruments Corporation 3 NI PXI-1042 Power Supply Shuttle User Guide Installation and Maintenance The information in t his section is for qualified service personnel only. Read the Read Me First: Safety and Radio-Frequency Interference documen t included with your kit before using the power supply shuttle. Caution Many components withi[...]
-
Page 4
NI PXI-1042 Power Supply Shuttle User Guide 4 ni.com Configuration The fan-speed selector switch is on the rear panel of the power supply shuttle. Refer to Fi gure 1 to locate the f an-speed selector. Select HIG H for maximum cooling performance (recommended) or AUTO for qui eter operation. When set to AUTO, air-intake temperature determines the fa[...]
-
Page 5
© National Instruments Corporation 5 NI PXI-1042 Power Supply Shuttle User Guide Efficiency ............ .............. .............. ....... 70% typical Power disconnect ............................ ....... The AC power cable provides main power disconnect. The chassis front-panel power switch causes the power supply to provide DC power to the C[...]
-
Page 6
NI PXI-1042 Power Supply Shuttle User Guide 6 ni.com Over-voltage protectio n 3.3 V and 5 V............... .............. ......Clamped at 20 to 30% above nominal output voltag e +12 V and – 12 V ...... ........... ............Clamped at 26 to 29 V difference between +12 and – 12 V outpu ts Power supply shuttle MTTR ................... Replacem[...]