National Instruments R Series Intelligent DAQ PCI/PXI-783xR manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of National Instruments R Series Intelligent DAQ PCI/PXI-783xR, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of National Instruments R Series Intelligent DAQ PCI/PXI-783xR one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of National Instruments R Series Intelligent DAQ PCI/PXI-783xR. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of National Instruments R Series Intelligent DAQ PCI/PXI-783xR should contain:
- informations concerning technical data of National Instruments R Series Intelligent DAQ PCI/PXI-783xR
- name of the manufacturer and a year of construction of the National Instruments R Series Intelligent DAQ PCI/PXI-783xR item
- rules of operation, control and maintenance of the National Instruments R Series Intelligent DAQ PCI/PXI-783xR item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of National Instruments R Series Intelligent DAQ PCI/PXI-783xR alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of National Instruments R Series Intelligent DAQ PCI/PXI-783xR, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the National Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of National Instruments R Series Intelligent DAQ PCI/PXI-783xR.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the National Instruments R Series Intelligent DAQ PCI/PXI-783xR item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Getting Started with R Series Intelligent DAQ This document explains ho w to install and configure National Instruments PCI/PXI-781 x R, PCI/PXI-783 x R, PXI-784 x R, and PXI-785 x R (NI 78 xx R) dev ices. This document also contains a tutorial section that demonstrates ho w to begin taking a measuremen t using a LabVIEW FPGA exa mp l e VI . Figure[...]

  • Page 2

    Getting Started with R Se ries Intelligent DAQ 2 ni.com Step 1. Install Application Software and Driver Before installing the NI 78 xx R, you need to install the application software and de vice dri ver . V isit ni.com/info and enter rdsoftwareversion to determine which minimum v ersions of software you need for the device you are using. Refer to t[...]

  • Page 3

    © National Instruments Corporat ion 3 Getti ng Started wi th R Series Intelligent DAQ Installing the NI 78 xx R Y ou can install the NI PCI-78 xx R in any a vailable PCI e xpansion slot in the computer , and the NI PXI-78 xx R in any av ailabl e peripheral slot in the PXI or CompactPCI chassis. T o achieve the best noise performance, leav e as muc[...]

  • Page 4

    Getting Started with R Se ries Intelligent DAQ 4 ni.com Figure 3. Instal ling an NI PX I-78 xx R Device in a PXI Chassis 5. For the NI PCI-78 xx R, secure the de vice mounting bracket to the computer back panel rail. For the NI PXI-78 xx R, secure the de vice front panel to the chassis front panel mounting rail using the front-panel mounting scre w[...]

  • Page 5

    © National Instruments Corporat ion 5 Getti ng Started wi th R Series Intelligent DAQ Step 3. Connect Signals Figure 4 shows the I/O connector pin assignments and locations for NI 781 x R Digital R Seri es devices. Figure 5 sho ws the I/O connector pin assignments and locations for NI 783 x R/784 x R/785 x R Multifunction R Series de vices. Figure[...]

  • Page 6

    Getting Started with R Se ries Intelligent DAQ 6 ni.com Figure 5. NI 783 x R/784 x R/785 x R Connector Pin Assignments and Loca tions Caution Connections that e xceed any of the maximum ratings of input or output signals on the NI 78 xx R can damage the NI 78 xx R device and the computer or chassis. NI is not li able for any damage resulting from s[...]

  • Page 7

    © National Instruments Corporat ion 7 Getti ng Started wi th R Series Intelligent DAQ The +5V terminals on the I/O connector supply +5 V referenced to D GND. Use these terminals to power external c ircuitry . All NI 78 xx R devices are equipped with a fuse to protect the supply from ov ercurrent conditions. Refer to the R Series Intellige nt DAQ U[...]

  • Page 8

    Getting Started with R Se ries Intelligent DAQ 8 ni.com Step 4. Using Y our NI 78 xx R Device with a LabVIEW FPGA Example VI (NI 783 x R/784 x R/785 x R Only) The NI-RIO dri ver installation includes a v ariety of example projects to he lp get you started. This section demonstrates how to use an e xisting LabV IEW FPGA example project to take an an[...]

  • Page 9

    © National Instruments Corporat ion 9 Getti ng Started wi th R Series Intelligent DAQ g. On the block diag ram, right-click the Open FPGA VI Reference function and choose Select VI from the shortcut menu. h. In the Select VI dialog box, select Analog Input (FPGA ).vi in the ne w target and click OK . i. In the Project Explorer windo w , right-clic[...]

  • Page 10

    Getting Started with R Series Intelligent DAQ 10 ni.com Adding Analog Outp ut to the FPGA Application T o e xpand the LabVIEW FPGA application to includ e analog output, complete the follo wing steps: 1. On the block diagram of Analog Input (FPGA).vi , insert a new frame betw een the f irst and second frames of the Flat Sequenc e structure by right[...]

  • Page 11

    © National Instruments Corporat ion 11 Getting Started with R Series I ntelligent DAQ 6. Right-click the input te rminal of the new FPGA I/O Nod e and select Create»Control from the shortcut menu. Rename the control A O V oltage , as shown in the follo wing block diagram. 7. Sav e the VI, then right-click Analog Input (FPGA).vi in the Project Exp[...]

  • Page 12

    Getting Started with R Series Intelligent DAQ 12 ni.com 9. On the front panel, locate the numeric control labeled A O V oltage . Right-click the control and select Num Ctrls»Kn ob from the Express controls palette to change the control type to knob . 10. On the front panel, click and hi ghlight the value in the lo wer limi t of the knob to change [...]

  • Page 13

    © National Instruments Corporat ion 13 Getting Started with R Series I ntelligent DAQ • National Instruments Example Finder —LabVIEW contains an e xte nsiv e library of VIs and example programs for use with R Series de vices. T o access the NI Exam ple Finder , open LabVIEW and select Help»Find Examples , then select Hardware Input and Outpu [...]

  • Page 14

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for m ore informat ion about Nation al Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trade names of their respective companie s. For patents coveri ng Nat[...]