Net Safety Net Safety AD-ST1400-25 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Net Safety Net Safety AD-ST1400-25, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Net Safety Net Safety AD-ST1400-25 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Net Safety Net Safety AD-ST1400-25. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Net Safety Net Safety AD-ST1400-25 should contain:
- informations concerning technical data of Net Safety Net Safety AD-ST1400-25
- name of the manufacturer and a year of construction of the Net Safety Net Safety AD-ST1400-25 item
- rules of operation, control and maintenance of the Net Safety Net Safety AD-ST1400-25 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Net Safety Net Safety AD-ST1400-25 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Net Safety Net Safety AD-ST1400-25, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Net Safety service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Net Safety Net Safety AD-ST1400-25.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Net Safety Net Safety AD-ST1400-25 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MILLENNIUM Oxygen Gas Detector User Manual Models: MLP-A/AR/AD-ST1400-25 & (all available options) Part Number: MAN-0060 Rev 04 August 2008[...]

  • Page 2

    [...]

  • Page 3

    Net Safety Monitoring Inc I MPORTANT I NFORMATION This manual is for inf ormationa l purposes only . Although e very ef fort has been made to ens ure the corr ectness of the infor mation, tec hnical i naccuracies may occur and peri odic change s may be made withou t notice. Net Saf ety Monitori ng Inc., ass umes no resp onsibility for any er rors c[...]

  • Page 4

    Net Safety Monitoring Inc T ABLE OF C ONTENTS Impor tant In forma tion Warranty Contact Information Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 The Product ....................... ........................... ........................... ......................... 1 The Sensor ..............[...]

  • Page 5

    Net Safety Monitoring Inc Outputs ............ ........................... ........................... ........................... .............. 18 Relays - Optional ........................ ................. ................. ................. ...................... 18 Modbus ........... ................. ................. ................. .....[...]

  • Page 6

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 1 I NTR ODUCTION The Millennium ser ies is Net Safe ty's late st innovation i n a line of continuous ly evolving indus trial gas det ectors and sensor s. The microcontr oller based syst em provides f ast, accurat e and continuo us monitoring o f gases in ex treme environments . T HE P RODUCT The[...]

  • Page 7

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 2 STEP 1 — P LAN L OCATE C ONTROLLER /S ENSOR Prior to t he installa tion proces s, a locat ion plan for placing the Contr oller and Sensor should be develo ped. Although ther e are no absolute rules fo r determinin g the quant ity and locat ion of a sens or or control ler , the following points sho[...]

  • Page 8

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 3 Figure 2: Dimens ional Drawings STEP 2 — I NSTALL U NPACK Carefully remove all components from t he packaging. Ch eck component s against th e enclosed packi ng list and inspect all co mponents for obvious damage such as broken or loose pa rts. If you find any components missing o r damaged, not [...]

  • Page 9

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 4 Mount The Controller is usu ally mounted near eye- level and be easily acce ssible for calibrat ion and mainten ance purpos es. The Sensor s hould be plac ed where O2 may build up or where other gase s are likel y to build up a nd displa ce O2. Ensure all devices are sec urely mount ed, taking int o[...]

  • Page 10

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 5 Board Assembly There are t hree dif ferent fi xed boards, two optional relay boa rds and an o ptional Modbus b oard which make up the PCB Assembly . Depending upon requir e ments, either a El ectromechani cal or Solid State Relay Boar d module can be used. Boards are fi eld replace able. Simply lo [...]

  • Page 11

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 6 Figure 5: Wiring—Controller a nd Sensor Note: If the 4-20 mA signal is not used, connect a jumper between the 4-20 termin al and the COM t erminal on th e T ermi nal Boar d. S ENSOR AND C ONTROLLER WA R N I N G : Power to the unit must be OFF before wiring. Note: The Sensor may be factory ins tall[...]

  • Page 12

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 7 S ENSOR S EPARATION Figure 6: Wi r i n g — Sensor Separation As the Sensor must be located in one location and the Con troller in a location where it ca n be easily reached, it is often necessary t o “separa te” the Contr oller and Sensor . The Sensor se paration kit (SEP) is composed o f a ju[...]

  • Page 13

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 8 N ON -I SOLATED /I SOLATED W IR ING T ermin al Connect ion Figure 7: Non-isolated T erminal Connection Figure 8: Isolated T erminal Connection Current Output T o set an isolated c urrent out put, si mply move the Jumper ( shorting jac k) to the isolated c urrent posi tion (refer to Figure 9, "J[...]

  • Page 14

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 9 R EMOTE R ESET The Millenni um can be set fo r remote rese t. A normall y open Push Button Switch must be connected between the RST and the COM terminals on the T erminal Board a nd the Relay Opt ion Latch S tatus mus t be set to Latc hing . Figure 10: Remote Reset MODBUS T ERMINATION Devices are ne[...]

  • Page 15

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 10 STEP 4 — O PERATE The Controller fa ceplate contai ns most functional eleme nts of the user interfa ce. Below is a description of that fu nctionalit y . Figure 12: Controller Funct ionality Status Red Slow Flash: Gas present Flast flash : Cal or Fault Solid: Overrange Pull Here Green Short Blips[...]

  • Page 16

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 11 RTU R eg i s t e r s Register 40001 = % output (read only) Register 40002 = R TU Status (read only) Register 40 101 = Reset lat ched relays (wr ite) Calibration Button The Calibrat ion Button prov ides acces s to the Millenni um’ s Main Menu, which in turn allows ca libration and op tions to be r[...]

  • Page 17

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 12 Magnetic Reed Switch The Magnetic Re ed Switch is pr ovided to avoid opening the Housi ng in an environme nt where gas may be pre sent. The Mag netic Reed Switc h functions in the same manner as the Calibrat ion Button but in a non-intr usive manner . Refer to Figure 12 , "Controlle r Function[...]

  • Page 18

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 13 STEP 5 — C ALIBRATE C ALIBRATION P ROCEDURE W ARNING: The calibrati on procedure req uires about 5 minut es to complete. If gas is not applied at the appropriat e time, a calib ration f ailure may occur ( refer to "Calibratio n Failure" on page 14 for specific inf ormation). For accura[...]

  • Page 19

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 14 Calibrat ion Failur e If the cal ibration pr ocedure fai ls, the di splay shows Fai l Cal , the Status LED alternat es Red and Gre en flashes a nd the anal og output changes back and fo rth from 3.0 to 3.3 mA. The unit rema ins in a f ailed stat e until manual ly reset. Aft er the Manu al Reset, th[...]

  • Page 20

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 15 R ELAY O PTIONS Use to set t he alarm leve l, coil stat us and latch status for the Low an d High relays ( Fault A larm is fi xed). The followin g table describes the def ault settings fo r the sensor . Ta b l e 4 : Default Rela y Settings Setting Relay Options There are t wo settings f or Relay O[...]

  • Page 21

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 16 M ODBUS O PTIONS The digital RS-485 Modbus R TU protocol is use d. There are two Modbus options: Nod e Address and Bau d Rate. Node Address Each device c onnected to t he chain must b e assigned a u nique node a ddress (1- 255). The last number in the addres s is selected first. St e p 1 : When Mod[...]

  • Page 22

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 17 S ELECT D ISPLAY L ANGUAGE St e p 1 : After t he Restrict ed Menu the opti on Select Di splay L anguage YES? display s. Press the Cali bration Butt on or use the Re ed Switch to select. The flashi ng YES confirms the s election. St e p 2 : When the require d language displa ys ( Englis h , Espan o[...]

  • Page 23

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 18 O UTPUT S Relays - Optional Note: The faul t relay outp ut is not used to activate an automatic shutdo wn procedure. Th e fault outp ut indica tes a potent ial problem with the Controller not an alarm condi tion. Standa rd elect ro-mechanical relay outputs have Form C SPDT contacts rate d 5 Amperes[...]

  • Page 24

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 19 H OW TO R ETURN E QUIPMENT A Material Retur n Authorizati on number is r equired in or der to retur n equipment. Pl ease conta ct Net Safet y Monitoring at (403) 219-0688 before returning equi pment or consult our Servi ce Department to possibl y avoid returning equi pment. If you are r equired to [...]

  • Page 25

    Net Safety Monitoring Inc MLP-A/AR/AD-ST1400-25 20 Rotate PCB Assembly 1. Remove the Controlle r ’ s Housing Cover . 2. T urn the power to the detect or of f. 3. Unscrew both the knobs marked "Pull Here". 4. Lift Contro ller facep late from Ho using and all ow to hang from r ibbon cable . 5. Unscrew the two metal st andoffs . 6. Careful[...]

  • Page 26

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 21 Appendix B: R ESISTANCE T ABLE IN OH MS Note: Resista nce shown is one way . This figure should be doubled when deter mining closed loop resistance. Distance (F eet) A WG #20 A WG #18 A WG #16 A WG #14 A WG #12 A WG #10 A WG #8 1 0 0 1 . 0 20 . 6 40 . 4 00 . 2 50 . 1 60 . 1 0 0 . 0 6 2 0 0 2 . 0 3[...]

  • Page 27

    Net Safety Monitoring Inc. MLP-A/AR/AD-ST1400-25 22 Appendix C: S PECIFICATI ONS S ENSOR S PECIFICATIONS C ONTROLLER S PECIFICATION SENSOR ELEMENT Oxygen O2 (ST1400) Operating T emperature Range -20°C to +50°C (-4F to +122F) % 5 2 o t 0 n o i t c e t e D f o e g n a R 5 9 T o t s d n o c e s 5 1 < e m i T e s n o p s e R r a e y / s s o l l a [...]

  • Page 28

    N et Safety Monitorin g Inc., 2 721 Hopewell Place NE C algary , Alb erta, Canada T 1Y 7J7 T elephone : (403) 21 9-0688 Fax : (403) 219- 0694 E -mail: netsafe@net-safety .com w ww .netsafety .com[...]