Go to page of
Similar user manuals
-
Network Card
NETGEAR XAVB6504
16 pages 1.42 mb -
Network Card
NETGEAR WPN111
87 pages 1.06 mb -
Network Card
NETGEAR RANGEMAX WPN111
4 pages 0.06 mb -
Network Card
NETGEAR XAVB101V2
2 pages 1.15 mb -
Network Card
NETGEAR PTV1000
2 pages 0.25 mb -
Network Card
NETGEAR FA311
2 pages 0.24 mb -
Network Card
NETGEAR AGM721F
1 pages 0.51 mb -
Network Card
NETGEAR AGM721F AGM721F AGM721F
1 pages 0.54 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of NETGEAR 7200 Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of NETGEAR 7200 Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of NETGEAR 7200 Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of NETGEAR 7200 Series should contain:
- informations concerning technical data of NETGEAR 7200 Series
- name of the manufacturer and a year of construction of the NETGEAR 7200 Series item
- rules of operation, control and maintenance of the NETGEAR 7200 Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of NETGEAR 7200 Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of NETGEAR 7200 Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the NETGEAR service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of NETGEAR 7200 Series.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the NETGEAR 7200 Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
202-10010-0 1 202-10010-01 November 2003 NETGEAR , Inc. 4500 Great America Parkway Santa Clara, CA User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Sof tware[...]
-
Page 2
ii 202-10010-0 1 © 2003 by NETGEAR, Inc., 202-10010-0 1 , Nov ember 2003. FullManual All rights res erv ed. T e chnical Support Please register to obtain technical support . Please retain your proof of p urchase and warranty information. T o register your pr oduct, get product support or obtain product information and product documentation, go to [...]
-
Page 3
202-10010-0 1 iii Canadian Dep artment of Commu nications Compliance St atement This Class B Digital apparatus (GSM7224 Layer 2 Managed Swit ch) meets all the require ments of the Canadian Interference Causing Equipment Regulations. Cet appareil numeri que del la cl asse B respect les exigen ces du Regalement sur le ma terial broilleur du Canada. T[...]
-
Page 4
202-10010-01 iv[...]
-
Page 5
Contents v 202-10010-01 Content s Chapter 1 About This Guide Audience ............. ................ ................ ................ ................ ................ ................ ......... ... 1-1 Why the Document was Created .................. ... ............. ................ ............. ................ ..... 1-1 How to Use This Docume[...]
-
Page 6
202-10010-0 1 vi Contents System-Wide Popup Menus .. ................. ................ ................ ................ ................ .. 5-4 Port-S pecif ic Popup Menus .......................... ................ ................ ................ ............ 5-4 Chapter 6 Quick St artup Quick S tarting the Switch ............. ...............[...]
-
Page 7
Contents vii 202-10010-01 Management Commands ...................... ................ ................ ................. ................ ...... 7-13 show network .. ................ ................ ............. ................ ................ ............. ............. 7-13 config network macaddr ......................... ... ... ... ........[...]
-
Page 8
202-10010-0 1 viii Contents config telnet mode ........................ ... ... .... ... ... ............. ... ... .... ... ... ... .... ... ... ............. ... 7-22 config telnet timeout . .... ... ... ............. ... .... ... ... ... ... .... ... ... ............. ... .... ... ... ... ... .... ... ... 7-22 show forwardingdb agetime ...... ...[...]
-
Page 9
Contents ix 202-10010-01 config vlan port ingressfilter ...... ............. ... ... ... ... .... ... ... ... .... ... ... ... .... ............ .... ... ... 7-33 show protocol ........................ ............. ................ ................. ................ ............. ...... 7-33 config protocol create ............ .... ... ... ... ...[...]
-
Page 10
202-10010-0 1 x Contents config macfilter create ..................... ... .... ... ... ... ... .... ............. ... ... ... .... ... ... ... ... .... ...... 7-43 config macfilter remove ... ... ............. ................ ............. ................ ................ .......... 7-44 config macfilter addsrc ....... ... .... ... ... ... .....[...]
-
Page 11
Contents xi 202-10010-01 show spanningtree mst port summary ......... ...... ................. ............. ................ ...... 7-55 show spanningtree mst port detailed ..... ................ ................ ................ ................ 7-55 show spanningtree vlan ............... ................ ............. ................ ..........[...]
-
Page 12
202-10010-0 1 xii Contents config dot1x port initialize ................... .... ... ... ... ... .... ... ... ............. ... .... ... ... ... ... .... ... ... 7-65 config dot1x port reauthenticate ................ ... ............. ................ ............. ................ 7-65 config dot1x port cont roldir ........ ................ ......[...]
-
Page 13
Contents xiii 202-10010-01 transfer upload fil ename ........ .... ... ... ... .... ... ... ... ... ............. .... ... ... ... .... ... ... ... ... .......... 7-76 transfer upload data type .............. ............. ................ ................ ................ ............. 7-76 transfer upload star t .................. ...............[...]
-
Page 14
202-10010-0 1 xiv Contents Appendix B Glossary Numeric .............. ............ ................. ................ ................ ............. ................ ............... .1 0 - 1 A ............... ............. ................ ................ ............. ................ ............. ................ ....... ...... 10-2 B .........[...]
-
Page 15
About This Guide 1-1 202-10010-01 Chapter 1 About This Guide Thank you for pu rchasing the NETGEAR ™ GSM7 224 L2 Switch. Audience This reference manual assumes that the reader h as basic-to-intermediate computer and Internet skills. However , basic computer ne twork, Internet, and wireless technology tutorial information is provided in the Append[...]
-
Page 16
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 1-2 About This Guide 202-10010-01 Note: Refer to the release notes for the GSM7224 Layer 2 Managed Switch Software application level code. The release notes de tail the platform specific func tionality of the Switching, SNMP , Config, and Management packages. T ypographical Con[...]
-
Page 17
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software About This Guide 1-3 202-10010-01 Features of the HTML V ersion of this Manual The HTML version of this manu al includes these feature s. Figure Preface -2: HTML version of t his manual 1. Left pane . Use the left pane to view the Conten ts, Index, Search, and Favorites tabs. [...]
-
Page 18
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 1-4 About This Guide 202-10010-01 How to Print this Manual T o print this manu al you man choose one of th e following several optio ns, according to your needs. • Printing a “How T o” Sequence of S teps in the HTML V iew . Use the Print button on the upper right of the t[...]
-
Page 19
Switch Management Overview 2-1 202-10010-01 Chapter 2 Switch Management Overview This chapter gives an overview of switch ma nagement, including the method s you can use to manage your NETGEAR GSM 7224 Layer 2 Manag ed Switch. • Management Access Overview • SNMP Access • Protocols Scope The GSM7224 Layer 2 Managed Switch software has two purp[...]
-
Page 20
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 2-2 Switch M anagement Overview 202-10010-01 • Simple Network Protocol Managemen t (SNMP) Each management method enables the network ad ministrator to configure, manage, and control the GSM7224 locally or remotely using in-ban d or out-of-band mechanisms. Management is standa[...]
-
Page 21
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Command Line Interface Syntax 3-1 202-10010-01 Chapter 3 Command Line Interface Synt ax The Command Line Interface (CLI) syn t ax , conventions and terminology are described in this section. Each CLI command is illustra ted using the structure outlined below . Format Commands [...]
-
Page 22
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 3-2 Command Line Interface Syntax 202-10010-01 Command The text in bold, non-italic font must be typed exactly as shown. Parameters Parameters are order dependent. The text in bold italics should be replaced with a name or number . T o use spaces as part of a name parameter , e[...]
-
Page 23
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Command Line Interface Syntax 3-3 202-10010-01 number 1. The <slot.port> field is composed of a valid slot number and a valid port number separated by a period (.). logical slot.port This parameter denote s a logical slot number and logical port number assigned. This is [...]
-
Page 24
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 3-4 Command Line Interface Syntax 202-10010-01 Annot ations The CLI allows the user to type single-line annotations at th e command prompt for use when writing test or configuration scripts and for bette r readability . The exclamation point (‘!’) character flags the beginn[...]
-
Page 25
Administration Consol e Telnet Interface 4-1 202-10010-01 Chapter 4 Administration Console T elnet Interface The administration console is an internal, character-oriented, VT -100/ANSI menu-driven user interface for performing management activities. Using this method, you can view the administration console from a terminal, PC, Apple Macintosh, or [...]
-
Page 26
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 4-2 Administration C onsole Teln et Interf ace 202-10010-01 Examples o f terminal-emu lation programs include: • HyperT erminal, which is included with Microsoft W indows operating systems • ZT erm for the Apple Macintosh • TIP for UNIX workstations This example describes[...]
-
Page 27
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Administrat ion Console Telnet Inte rface 4-3 202-10010-01 4. When the following screen appe ars, make sure that the port setting are as follows: Baud Rate: 9600 Data Bits: 8 Parity: None Stop Bits: 1 Flow Control: None Figure 4-4: Connectio n Settings 5. Click OK. The HyperT [...]
-
Page 28
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 4-4 Administration C onsole Teln et Interf ace 202-10010-01[...]
-
Page 29
Web-Based Manage men t Interface 5-1 202-10010-01 Chapter 5 W eb-Based Management Interface Y our NETGEAR GSM7224 Layer 2 Managed Switch provides a built-in browser interface that lets you configure and man age it remotely using a standard W eb browser such as Microsoft Internet Explorer 5.0 or la ter or Netscape Naviga tor 6.0 or later . This inte[...]
-
Page 30
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 5-2 We b-Based Ma nagement Interface 202-10010-01 • Device Management Introduction of the basic icons and management of the device • Interface Opera tions Describes W eb brow ser requirements, and common commands • Product Overview Describes supported SNMP an d W eb manag[...]
-
Page 31
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Web-Based M anagement Interface 5-3 202-10010-01 4. T ype the default user name of admin and default of no password , or whatever password you have set up. Once you have entered your access point name, your W eb browser should automatically find the GSM7224 L2 Switch and displ[...]
-
Page 32
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 5-4 We b-Based Ma nagement Interface 202-10010-01 System-Wide Popup Menus The GSM7224 L2 Switch also provides several popup menus. Y ou can also access the main navigation menu by right clicking on the image of the switch and browsing to the menu you wa nt to use. Port-S pecifi[...]
-
Page 33
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Quick Startup 6-1 202-10010-01 Chapter 6 Quick S t artup The Command Line Interface Quick Startup chap ter details procedures to quickly become acquainted with the GSM7224 Layer 2 Managed Switch software. This chapter contains the following Quick S tartup examples: • “Syst[...]
-
Page 34
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 6-2 Quick Startup 202-10010-01 System Info and System Setup There are several categories of Quick Startup commands: • “Quick Startup Software V ersio n Information” on page 6-2 • “Quick Startup Physical Port Data” on page 6-3 • “Quick Startup User Account Mana g[...]
-
Page 35
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Quick Startup 6-3 202-10010-01 Quick S t artup Physical Port Dat a T able 6-2. Quick S t artup Physical Port Dat a Quick S t artup User Account Management Command Details show port all Displays the Port Characteristics Slot.Port - slot number .port numbe r Slot Options: 0 - th[...]
-
Page 36
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 6-4 Quick Startup 202-10010-01 Quick S t artup IP Address T o view the network parameters the operator can access the device by the following three methods. • Simple Network Management Protocol - SNMP •T e l n e t • W eb browser Note: Helpful Hint - do a save config after[...]
-
Page 37
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Quick Startup 6-5 202-10010-01 Default Gateway - The defaul t Gateway for this interface Default value is 0.0.0.0 Burned in MAC Address - The Burned in MAC Address used for in-band connectivity Locally Administered MAC Address - Can be configured to allow a locally administere[...]
-
Page 38
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 6-6 Quick Startup 202-10010-01 Quick S t artup Uploading from Sw itch to Out-of-Band PC (Only XMODEM) Quick S tartup Downloading from Ou t-of-Band PC to Switch (Only XMODEM) T able 6-5. Quick S t artup Uploading from Switch to Out- of-Band PC (Only XMODEM) Command D et ails tra[...]
-
Page 39
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Quick Startup 6-7 202-10010-01 Quick S t artup Downloading from TFTP Server Before starting a TFTP server download, the operat or must complete the Quick Startup for the IP Address. Quick S t artup Factory Default s T able 6-7. Quick S t artup Downloading fr om TFTP Server Com[...]
-
Page 40
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 6-8 Quick Startup 202-10010-01 VLAN Configuration Example This section provides conf iguration examples for VLAN configurations. LAN switches can segment networks into logica lly defined virtual workgroups.This logical segmentation is commonly refe rred as a virtual LAN (VLAN).[...]
-
Page 41
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Quick Startup 6-9 202-10010-01 Solution 1 All traf fic entering the ports is tagged traffi c. Since the traf fic is tagged, the PVID configuration for each port is not a concern. The ne twork card configur ation is as follows: • Devices on Project A should tag all traf fic w[...]
-
Page 42
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 6-10 Quick Startup 202-10010-01[...]
-
Page 43
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-1 202-10010-01 Chapter 7 Switching Commands This chapter provides detailed explanation of the Switching commands. The commands are divided into five fun ctional groups: • Show commands display switch settings, statistics, and ot her information. • Conf[...]
-
Page 44
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-2 Switching Commands 202-10010-01 Switch Description T ext used to identify the product name of this switch. Machine T ype Specifies the machine model as de f ined by the V ital Product Data. Machine Model Specifies the machine model as de fined by the V ital Product Data. Se[...]
-
Page 45
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-3 202-10010-01 config syslocation This command sets the physical location of the switch. The rang e for the name is from 1 to 31 alphanumeric characters. Default Blank Format config syslocation < location > config syscont act This command sets the or[...]
-
Page 46
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-4 Switching Commands 202-10010-01 Slot.Port The port which this address was learned. if Index This object indi cates the ifInde x of the interface table entry associa ted with this port. Stat us The status of this en try . The meanings of the values ar e: St a t i c - The val[...]
-
Page 47
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-5 202-10010-01 Octets Received - the total number of octets of data (including those in bad packets) received on the network (exc luding framing bits but including FCS octets). This object can be used as a reasonable est imate of ethe rnet utilizatio n. If[...]
-
Page 48
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-6 Switching Commands 202-10010-01 To t a l - the total number of inbound packets that contained errors preventing them from b eing deliverable to a higher -layer protocol. Jabbers Receive d - the total number of packets re ceived that were longer than 1518 octets (excluding f[...]
-
Page 49
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-7 202-10010-01 CFI Discards - the number of frames discarded that have CFI bit set and the addresses in RIF are in non-canonical format. Up s tre a m T hre s h o l d - the number of frames discar ded due to lack of cell descriptors available for that packe[...]
-
Page 50
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-8 Switching Commands 202-10010-01 To t a l E r r o r s - the sum of Single, Multiple, and Excessive Collisions. FCS Errors - the total number of packets transmitted that had a length (excluding framing bi ts, but including FCS octe ts) of between 64 and 1518 octets, inclusive[...]
-
Page 51
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-9 202-10010-01 STP BPDUs T ransmitted - Spanning T ree Protocol Br idge Protocol Data Units sent STP BPDUs Received - Spanning Tree Protocol Br idge Protocol Data Units received RST BPDUs T ransmitted - Rapid Spanning Tree Pr otocol Bridge Pro tocol Data U[...]
-
Page 52
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-10 Switching Comm a nd s 202-10010-01 show stat s switch de t ailed This command displays detailed statistics for all CPU traf fic. Format show stats switch detailed T otal Packets Received (Octets) - the total number of octets of data received by the processor (excluding fra[...]
-
Page 53
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-1 1 202-10010-01 Most VLAN Entries Ever Used - the lar gest number of VLANs th at have been active on this switch since the last reboot. S tatic VLAN Entries - the number of pr esently active VLAN entries on th is switch that have been created static ally [...]
-
Page 54
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-12 Switching Comm a nd s 202-10010-01 show eventlog This command displays the even t log, which contains error me ssages from the system. The event log is not cleared on a system reset. Format show eventlog File The file in which the event originated. Line The line number of [...]
-
Page 55
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-1 3 202-10010-01 Management Commands These commands manage the switch and show current management settings. show network This command displays network configuration settings that are vital for switch operation. Format show network IP Address The IP addres [...]
-
Page 56
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-14 Switching Comm a nd s 202-10010-01 • Bit 7 of byte 0 (called the I/G bit) indicates wh ether the destination addr ess is an individual address (b'0') or a group address (b'1'). • The second character , of the twelve char acter macAddr , must be 2, 6[...]
-
Page 57
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-1 5 202-10010-01 Default enable Format config network webmode < enable|disab le > config network javamode This command specifies whether or not the switc h should allow access to the Java applet in the header frame of the W eb interface. When access [...]
-
Page 58
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-16 Switching Comm a nd s 202-10010-01 config serial baudrate This command specifies the communication rate of the terminal interface. The supported rates are 1200, 2400, 4800, 9600, 1 9200, 38400, 576 00, 1 15200. Default 9600 Format config serial baudrate <speed> confi[...]
-
Page 59
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-1 7 202-10010-01 show snmpco mmunity This command displays SN MP community information. Six communities are supported. Y o u can add, change, or delete communities. The switch does not have to be reset for changes to take effect. The SNMP agent of the swit[...]
-
Page 60
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-18 Switching Comm a nd s 202-10010-01 config snmpcommunity create This command adds (and na mes) a new SNMP community . A community name is a name associated with the switch and with a set of SNMP managers that manage it with a specified privileged level. The length of name c[...]
-
Page 61
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-1 9 202-10010-01 config snmpcommunity mode This command activates or deactivates an SNMP community . If a community is enabled, an SNMP manager associated with th is community manages the switch according to its access right. If the community is disabled, [...]
-
Page 62
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-20 Switching Comm a nd s 202-10010-01 config snmptrap ip addr This command assigns an IP address to a spec ified community name. Th e maximum length of name is 16 case-sensitive alphanumeric characters. Note: IP addresses in the SNMP trap receiver table must be un iq ue. If y[...]
-
Page 63
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-2 1 202-10010-01 config trap flags authentication This command enables or disables the Authentication Flag. Default enable Format config trapflags authentication <ena ble|disable> config trap flags bcast storm This command enables or disables the bro[...]
-
Page 64
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-22 Switching Comm a nd s 202-10010-01 show telnet This command displays telnet settings. Format show telnet T elnet Login Timeout (minutes) This object indicates the numbe r of mi nutes a telnet sessio n is allowed to remain inactive before being logged of f.A zero means ther[...]
-
Page 65
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-2 3 202-10010-01 Default 5 Format config telnet timeout <0-160> show forwarding db agetime This command displays the timeout for address aging. In an IVL system, the [fdbid|all] parameter is required. In an SVL system, the [fdbid|all] parameter is no[...]
-
Page 66
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-24 Switching Comm a nd s 202-10010-01 show switchconfig This command displays switch configuration information. Format show switchconfig Broadcast Storm Recovery Mode May be enabled or disabled by select ing the corresponding line on the pull- down entry field. The fact ory d[...]
-
Page 67
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-2 5 202-10010-01 Format show port <slot.port|all> Slot.Port The physical slot and physical port. Ty p e If not blank, this fi eld indicates that thi s port is a special type of port. The possible values are: Mon - this port is a monitoring port. Look[...]
-
Page 68
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-26 Switching Comm a nd s 202-10010-01 config port linktrap This command enables or disabl es link status traps by interface. Note: This command is valid only wh en the Link Up/ Down Flag is enabled. See “config trapflags linkmode” on page 21 for more information. Format c[...]
-
Page 69
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-2 7 202-10010-01 Logical Slot.Po rt The logical slot and the logical port. Lag Name The name of this lag. Y ou may ente r any string of up to 15 alphanumeric characters. Link State Indicates whether the Link is up or down. Admin Mode May be enabled or disa[...]
-
Page 70
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-28 Switching Comm a nd s 202-10010-01 config lag adminmode This command enables or disables a LAG . The interface is a logi cal slot and port for a configured LAG . The option all sets every configured LAG with the same administrative mode setting. Format config lag adminmode[...]
-
Page 71
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-2 9 202-10010-01 The mode is one of the following: 802.1d IEEE 802.1D-compl iant STP mode is used. fast Fast STP mode is used. off STP is turned off. show vlan summary This command displays a list of all configured VLANs. Format show vlan summary VLAN ID T[...]
-
Page 72
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-30 Switching Comm a nd s 202-10010-01 Current Determines the degree of participa tion of this port in this VLAN. The permissible values are : Include - this port is always a member of this VLAN. This is equivalent to registration fixed in th e IEEE 802.1Q standard. Exclude - [...]
-
Page 73
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-3 1 202-10010-01 Default The name for VLAN ID 1 is always De fault. The name fo r other VLANs is defaulted to a blank string. Format config vlan name <name> <2-4094> config vlan makest atic This command changes a dynamically created VLAN (one t[...]
-
Page 74
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-32 Switching Comm a nd s 202-10010-01 show vlan port This command displays VLAN port information. Format show vlan port <slot.port> Slot.Port Indicates by slot id and po rt number which port is cont rolled by the fields on this line. It is possible to set the param eter[...]
-
Page 75
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-3 3 202-10010-01 Format config vlan port acceptframe < all|vlan > <slot.port|all> config vlan port ingressfilter This command enables or disables ingress filtering. If ingress fi ltering is disabled, frames received with VLAN IDs that do not ma[...]
-
Page 76
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-34 Switching Comm a nd s 202-10010-01 config protocol protocol add This command adds the <protocol> to the protocol-based VLAN identif ied by <groupid>. A group may have more than on e pro tocol associated with it. Each interface and protocol com bination can only[...]
-
Page 77
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-3 5 202-10010-01 config protocol interface add This comma nd adds the physica l <slot.port> interface to the protocol -based VLAN identified by <groupid> . If <all> is selected, all physical interfaces will be added to this protocol group[...]
-
Page 78
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-36 Switching Comm a nd s 202-10010-01 participant basis. Permissi ble values are 10 to 100 centiseconds (0.1 to 1.0 seconds). The factory defa ult is 20 centiseconds (0.2 seconds). The finest granularity of specification is 1 cen tisecond (0.01 seconds). Leave Timer Specifies[...]
-
Page 79
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-3 7 202-10010-01 config garp gvrp adminmode This command enabl es or disables GVRP . Default disable Format config garp gvrp adminmode <enable|d isable> config garp gvrp interface mode This command enables or disab les GVRP (GARP VLAN Re gistra tion [...]
-
Page 80
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-38 Switching Comm a nd s 202-10010-01 config garp leavealltimer This command sets how frequently Leave All P DUs are generated per port. A Lea ve All PDU indicates that all registrations will be unregistered. Participants would need to rejoin in order to maintain registration[...]
-
Page 81
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-3 9 202-10010-01 config igmp snooping adminmode This command enables or disabl es IGMP Snooping on the system . The default value is disable. Format config igmpsnoopi ng ad minmode <ena ble/disable> config igmp snooping groupmembershipinterval This c[...]
-
Page 82
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-40 Switching Comm a nd s 202-10010-01 config igmp snooping interface mode This command enables or disabl es IGMP Snoo ping on a sele cted interface. The <slot.port/all> parameter identifies the interface on which to conf igure the mode. If an interface which has IGMP Sn[...]
-
Page 83
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-4 1 202-10010-01 Mac Address A unicast MAC address for which the sw itch has forwarding and or filtering information. The format is 6 or 8 tw o-digit hexadecimal numbers that are separated by colons, for example 01:23: 45:67:89:AB. In an I VL system the MA[...]
-
Page 84
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-42 Switching Comm a nd s 202-10010-01 Description The text description of this mu lt ica st table entry . Interfaces The list of interfaces that ar e designat ed for f orwarding (Fwd:) and filtering (Flt:). show mfdb st at s This command displays th e Multicast Forwarding Dat[...]
-
Page 85
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-4 3 202-10010-01 config mirroring delete This command removes the port mirroring design ation from both the probe port and the mirrored port and removes the probe port fro m all VLANs. The port must be manually re-added to any desired VL AN s . Format conf[...]
-
Page 86
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-44 Switching Comm a nd s 202-10010-01 The <vlan> parameter must identify a valid VLAN. Up to 100 static MAC filters may be created. Format config macfilter create <macaddr> <v lan> config macfilter remove This command removes all filtering restrictions and t[...]
-
Page 87
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-4 5 202-10010-01 If all is selected, all ports will be removed from the source port filter set. Format config macfilter delsrc <macaddr> <v lan> <slot.port|all> config macfilter adddest This command adds the <slot.port> to the desti[...]
-
Page 88
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-46 Switching Comm a nd s 202-10010-01 • Show commands display spanning tree settin gs, statistics, an d other informat ion. • Config commands configure features and opt ions of the switch. For every config command there is a show command that displays the config setting. [...]
-
Page 89
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-4 7 202-10010-01 config sp anningtree forceversion This command sets the Force Protocol V ersion pa rameter to a new value. The <version> can be one of the following: • 802.1d - ST BPDUs are transmitted rather than MST BPDUs (IEEE 802.1d funct iona[...]
-
Page 90
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-48 Switching Comm a nd s 202-10010-01 Port Up T ime Since Counters Last Clea red T ime since port was rese t, displayed in days, h ours, minutes, and seconds. STP BPDUs T rans mitted Spanning T ree Protocol Bridge Protocol Data Units sent. STP BPDUs Received Spanning T ree Pr[...]
-
Page 91
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-4 9 202-10010-01 config sp anningtree bridge maxage This command sets the Bridge Max Age paramete r to a new value for the common and internal spanning tree. The maxage <value> is in whole se conds within a range of 6 to 40, with the value being less[...]
-
Page 92
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-50 Switching Comm a nd s 202-10010-01 Format show spanningtree cst detailed Bridge Priority Configured value. Bridge Identifier Time Since T opolo gy Change In seconds. T opology Ch ange Count Number of times changed. T opology Change Boolean value of the T opology Change pa [...]
-
Page 93
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-5 1 202-10010-01 show sp anningtree cst port det ailed This command displays the settings and parameters for a specific switch po rt within the common and internal spanning tree. The <s lot.port> is the desired switch port Format show spanningtree cs[...]
-
Page 94
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-52 Switching Comm a nd s 202-10010-01 config sp anningtree cst port priority This command sets the Port Prio rity to a new value for use w ithin the common and internal spanning tree. The <slot.port> is the desired switch port. The prior ity <value> is a number in[...]
-
Page 95
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-5 3 202-10010-01 config sp anningtree mst vlan add This command adds an association between a multiple spanning tree in stance and a VLAN. The VLAN will no longer be associated with the comm on and internal spanning tree. The instance <mstid> is a nu[...]
-
Page 96
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-54 Switching Comm a nd s 202-10010-01 config sp anningtree mst port priority This command sets the priority for a specific port within a specifi c multiple spanning tree instance. The instance <mstid> is a number that corresponds to the desir ed existing multiple spanni[...]
-
Page 97
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-5 5 202-10010-01 show sp anningtree mst port summary This command displays the settings of one or all ports within the specifie d multiple spanning tree instance. The parameter <mstid> indicates a partic ular MST instance. The parameter <slot.port[...]
-
Page 98
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-56 Switching Comm a nd s 202-10010-01 VLAN Identifier Associated Instance Identifier for the ass oci ated multiple spanni ng tree instance or "CST" if associated with the com mon an d internal spanning tree. User Account Management Commands These commands manage use[...]
-
Page 99
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-5 7 202-10010-01 config users p asswd This command changes the passwo rd of an existing operator . Th e password is up to eight alphanumeric characters . The name and password are not case-sensitive. When a password is changed, a prompt will ask fo r the o[...]
-
Page 100
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-58 Switching Comm a nd s 202-10010-01 config users snmpv3 accessmode This command specifies the snmpv3 access priv ileges for the specified login user . The valid accessmode values are readonly or readwrite . The <user> is the login user name for which the specified acc[...]
-
Page 101
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-5 9 202-10010-01 config radius maxretransmit This command sets the maximum number of times a request packet is retransmitted when no response is received from the RADIUS server . The maxretransmit value is an integer in the range of 1 and 1 5. Consideratio[...]
-
Page 102
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-60 Switching Comm a nd s 202-10010-01 Format config radius accounting mode < enable/disable> config radius accounting server add This command configures the IP address to us e fo r the accounting server . Only a single accounting server can be configured. If an accounti[...]
-
Page 103
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-6 1 202-10010-01 config radius server add This command configures the IP address to use to connect to a RADIUS server . Up to 3 servers can be configured per RAD IUS client. If the ma ximum number of configured servers has been reached, this comma nd will [...]
-
Page 104
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-62 Switching Comm a nd s 202-10010-01 config radius server primary This command specifies which co nfigured server should be the primary server for this RADIUS client. The primary is the server that is used by default for handlin g RADIUS requests. The remaining configured se[...]
-
Page 105
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-6 3 202-10010-01 Current Indicates the configured server cu rrently in use for authentication. IP address The configured IP addr ess of the authentication server . Port The port in use by this server . Ty p e Primary or Secondary . Secret Configured Y es o[...]
-
Page 106
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-64 Switching Comm a nd s 202-10010-01 show radius accounti ng summary This command displays th e configured accounting mode and accounting server . Format show radius accounting summary Mode Enabled or Disabled. IP address The configured IP address of the accounting server . [...]
-
Page 107
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-6 5 202-10010-01 show radius st at s This command displays the RADIUS statistics that are not related to a specific server or to the accounting server . Format show radius stats Invalid Server Addre sse s The number of RADIUS Access-Res ponse packets recei[...]
-
Page 108
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-66 Switching Comm a nd s 202-10010-01 config dot1x port controldir This command configures the control direction for the specified port or po rts. The control direction dictates the degree to which protocol exchanges take place between Suppl icant and Authenticator . This aff[...]
-
Page 109
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-6 7 202-10010-01 config dot1x port transmitpe riod This command sets the value, in seconds, of the timer used by th e authenticator state machine on the specified port to determin e when to send an EAPOL EAP Request/Identity frame to the supplicant. The tr[...]
-
Page 110
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-68 Switching Comm a nd s 202-10010-01 Default 3600 Format config dot1x port reauthperiod <slot.port> <1-65535> config dot1x port reauthenabled This command enables or disabl es reauthentication of the supplicant for the specified port. The reauthenabled value must[...]
-
Page 111
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-6 9 202-10010-01 Protocol V ersion The protocol version associated with th is port. The only possible value is 1, corresponding to the first vers ion of the dot1x specification. PA E C a p a b i l i t i e s The port access entit y (P AE) functionality of t[...]
-
Page 112
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-70 Switching Comm a nd s 202-10010-01 EAPOL Frames T ransmitted The number of EAPOL frames of any type that have been transmitted by this authenticator . EAPOL St art Frames Received The number of EAPOL start frames that have been received by this authenticator . EAPOL Logoff[...]
-
Page 113
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-7 1 202-10010-01 Default None Format config authentication login create < listname> config authentication login delete This command deletes the specified authentication login list. The at tempt to delete will fail if any of the following conditions a[...]
-
Page 114
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-72 Switching Comm a nd s 202-10010-01 config dot1x defaultlogin This command assigns the authenti cation login list to use for noncon figured users for 802.1x port security . This setting is overridden by the authentication login list assi gned to a specific user if the user [...]
-
Page 115
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-7 3 202-10010-01 config users login This command assigns the specified authentication login list to the sp ecified user for system login. The <user> must be a configured <user> and the <listname> must be a configured login list. If the us[...]
-
Page 116
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-74 Switching Comm a nd s 202-10010-01 User This field disp lays the user s configured locally to have access to the sp ecified port. show users authentication This command displays all user and all authentic ation login information. It also displays the authentication login l[...]
-
Page 117
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-7 5 202-10010-01 Format transfer upload mode <xmodem|tftp> transfer upload serverip This command sets the IP address of th e server on which the file is located. Note: This command is valid only wh en the transfer mode is TFTP . See “transfer uploa[...]
-
Page 118
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-76 Switching Comm a nd s 202-10010-01 transfer upload filename This command sets the name for the file that is uploaded fro m the switch. The switch “remembers” the last file name used. Append the file path to the file name if t he stri ng is less than 31 characters. Othe[...]
-
Page 119
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-7 7 202-10010-01 transfer download serverip This command configures the IP address of the server on which the file is located. Note: This command is valid only when the transfer mode is TFTP . See “transfer download mode” . Default 0.0.0.0 Format trans[...]
-
Page 120
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-78 Switching Comm a nd s 202-10010-01 transfer download st art This command starts a download transfer after displaying current settings and upon confirmation. Format transfer download start clear transfer This command resets the file transfer co nfigured values to the factor[...]
-
Page 121
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Switching Commands 7-7 9 202-10010-01 clear lag This command clears all LAGs. Format clear lag clear st at s port This command clears the stat s for a specified <slot.port> Format clear stats port <slot.port> clear st at s switch This command clears the stats for t[...]
-
Page 122
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 7-80 Switching Comm a nd s 202-10010-01 ping This command checks if another computer is on the network and listens for connections. T o use this command, configure the switch for networ k (in-band) connection (as described in the FA S T PA T H np 2402/4802 Hardwar e User Guide [...]
-
Page 123
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Differentiated Services 8-1 202-10010-01 Chapter 8 Differentiated Services This chapter contains the Command Line Interface (CLI) commands used for the QOS Differentiated Services (Dif fServ) package. The GSM7224 Layer 2 Managed Switch provides a simplified in terface for enab[...]
-
Page 124
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 8-2 Differentiated Services 202-10010-01[...]
-
Page 125
Cabling Guidelines A-1 202-10010-01 Appendix A Cabling Guidelines This appendix provides spec ifications for cables used wi th a NETGEAR GSM7224 Layer 2 Managed Switch. Fast Ethernet Cable Guidelines Fast Ethernet uses UTP cable, as specified in the IEEE 802.3u standard for 100BASE-TX.The specification requires Category 5 UTP cable consis ting of e[...]
-
Page 126
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software A-2 Cabling Guidelines 202-10010-01 Category 5 Cable Category 5 distributed cable that me ets ANSI/EIA/ TIA-568-A building wiring stan dards can be a maximum of 328 feet (ft.) or 10 0 meters (m) in length, div ided as follows: 20 ft. (6 m) between the hu b and the patch panel ([...]
-
Page 127
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Cabling Guidelines A-3 202-10010-01 T able 8-1. Electrical Requir ement s of Category 5 Cable T wisted Pair Cables For two devices to communicate, th e transmitter of each device must be connected to the receiver of the other device. The cro sso ver function is usually impleme[...]
-
Page 128
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software A-4 Cabling Guidelines 202-10010-01 Figure 8-2 illustrates crossover twisted pair cable. Figure 8-2: Crossover T wisted-Pair Cable Patch Panels and Cables If you are using patch panels, make sure th at they meet the 100BASE- TX requirements. Use Category 5 UTP cable for all pat[...]
-
Page 129
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Cabling Guidelines A-5 202-10010-01 Note : Flat “silver satin” teleph one cable may have the same RJ-45 plug . However , using teleph one cable results in excessive collisio ns, causing the attached port to be partitioned or disconnected from the network. Using 1000BASE-T [...]
-
Page 130
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software A-6 Cabling Guidelines 202-10010-01 Unlike 10BASE-T and 100BASE-TX, which use only two of the four pairs of wires wit hin the Category 5, 1000BASE-T u ses all four pairs of th e twisted pair . Make sure all wires are tested ⎯ this is important. Factors that affect the return [...]
-
Page 131
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Cabling Guidelines A-7 202-10010-01 Figure 8-4 shows the RJ-45 plug and RJ-45 connector . Figure 8-4: RJ-45 Plug and RJ-45 Connector with Built-in LEDs Ta b l e 8 - 1 lists the pin assignments for the 10/100 Mbps RJ-45 plug and the RJ-45 connector . T able 8-1. 10/100 Mbp s RJ[...]
-
Page 132
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software A-8 Cabling Guidelines 202-10010-01 T able 8-2. 100/1000 Mbp s RJ-45 Plug and RJ-45 Connect or Pin Assignment s Conclusion For optimum performanc e of your 1000BASE-T product, it is important to fully qualify you r cable installation and ensure it meets or exceeds ANSI/EIA/TIA-[...]
-
Page 133
Glossary B-1 202-10010-01 Appendix B Glossary Use the list below to find definitions for technical terms used in this manual. Numeric 802.1D The IEEE designator for Spanning Tree Protocol (STP). STP , a link managem ent proto col, is part of the 802.1D standard for media access contro l bridges. Using the spanning tr ee algorithm, STP provides path[...]
-
Page 134
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software B-2 Glossary 202-10010-01 100BASE-TX The IEEE specification for 100 Mbps Fast Ethernet over Category 5 twisted-pair cabl e . 1000BASE-SX The IEEE specification for 1000 Mbps Gigabit Ethernet over fib er-optic cable. 1000BASE-T The IEEE specification for 1000 Mbps Gigabit Et her[...]
-
Page 135
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Glossary B-3 202-10010-01 Baud The signaling rate of a line, that is, the number of tr ansitions (voltage or frequency changes) made per second. Also known as line speed. BootP See “Bootstrap Protocol” on page 3. Boot strap Protocol An Internet protocol that enables a disk[...]
-
Page 136
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software B-4 Glossary 202-10010-01 CLI See “Command Line Interface” on page 4. Collision A term used to describe two colliding packets in an Et hern et network. Collisions are a part of normal Ethernet operation, but a sudden prolonged increase in the number of collisions can in dic[...]
-
Page 137
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Glossary B-5 202-10010-01 198.105.232.4. The DNS syst em is, in fact, its own ne t work. If one DNS server doesn't kn ow how to translate a particular domain name, it asks another one , and so on, until the correct IP address is returned. Domain Name A descriptive name fo[...]
-
Page 138
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software B-6 Glossary 202-10010-01 Ethernet A LAN specification develo ped jointly by Xerox, Inte l and Digi tal Equi pment Corporation. Ethernet networks transmit packets at a rate of 10 Mbps. F Fast Ethernet An Ethernet system that is designed to operate at 100 Mbps. Fault isola tion [...]
-
Page 139
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Glossary B-7 202-10010-01 G GARP See “Generic Attribute Registration Prot ocol ” on pa ge 7. GARP Information Propagation GIP is the propagation of information between GARP part icipants for the same applicatio n in a bridg e is carried out by a GIP component. GARP Multica[...]
-
Page 140
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software B-8 Glossary 202-10010-01 GVRP See “GARP VLAN Registration Protocol” on page 7. H Half-duplex A system that allows packets to transmitted and received, but not at the same time. Contrast with full-duplex. I IEEE Institute of Electrical and Electronics Engineers. This Americ[...]
-
Page 141
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Glossary B-9 202-10010-01 IP Multicasting Sending out data to distributed servers on the MBone (Multi cast Backbone). For large amounts of data, IP Multicast is more efficient than norm al Internet transmissions because th e server can broadcast a mess age to many recipients s[...]
-
Page 142
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software B-10 Glossary 202-10010-01 Local Area Network A communications netwo rk serving users within a limi ted area, such as one floor of a buildi ng. A LAN typically connects multiple personal co mputers and shared network devices such as storage and printers. Although many technolog[...]
-
Page 143
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Glossary B-11 202-10010-01 MDI/MDIX In cable wiring, the concept of transm it and receive are from the perspec tive of the PC, which is wired as a Media Dependant Interface (MDI). In MDI wiring, a PC transmits on pins 1 and 2. At the hub, switch, router , or access point, the [...]
-
Page 144
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software B-12 Glossary 202-10010-01 them, and are the only areas that can contain an ASBR. Compare with st ub area. See also ASAM and OSPF . (Cisco Systems Inc.) O Open Systems Inter connection OSI is a seven (7) layer architecture model for commun icatio ns systems developed by the ISO[...]
-
Page 145
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Glossary B-13 202-10010-01 packet bound for or headin g away from the first port w ill be forwarded o nto the second port as well. The administrator places a protocol anal yzer on the port receiving the mirrored data to moni tor each segment separately . The analyzer captures [...]
-
Page 146
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software B-14 Glossary 202-10010-01 Using RADIUS, you must enter your user name and password before gaining access to a network. This information is passed to a RADIUS server, which checks that the information is co rrect, and then authorizes access. Though not an official standard, the[...]
-
Page 147
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Glossary B-15 202-10010-01 SNMPsec (historic): Security is based on part ies. Few , if any , vendors implemented this version of the protocol, which is now largely forgotten. SNMPv2p (historic): For this v ersion, much work was don e to update the SNMPv1 protocol and the SMIv1[...]
-
Page 148
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software B-16 Glossary 202-10010-01 STP Spanning Tree Protocol. See “802.1D” on page 1 for more information. stub area OSPF area that carries a default rout e, intra-area routes, and interarea routes, but does not carry external routes. V irtual links cannot be con figured across a [...]
-
Page 149
User Manual for the NETGEAR 7200 Series La yer 2 Managed Switch Software Glossary B-17 202-10010-01 T runking The process of combing a set of trunks that are tr affic-engineered as a unit for the establishment of connections between switching systems in which a ll of the communications paths are interchangeable. U USP An abbreviation that repr esen[...]
-
Page 150
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software B-18 Glossary 202-10010-01 Wide Area Network A W AN is a computer network that spans a relatively large ge ographical area. T ypically , a W A N consists of two or more local-area networks (LANs). Windows Internet Naming Service WINS. W indows Internet Naming Servi ce is a serv[...]
-
Page 151
Index 1 A Address Resolution Protocol. See ARP ARP cache, displaying 7-3 authentication login create 7-70 login delete 7-71 login set 7-71 show login info 7-73 show login users 7-73 Authentication Flag 7-21 Auto MDI/MDI-X 10-2 Auto Uplink 10-2 B baud rate 7-16 boot code 7-79 Bootstrap Protocol (BOOTP) 7-14 broadcasts broadcast storm recovery mode 7[...]
-
Page 152
2 Index config protocol vlan remove 7-34 config radius accounting mode 7-59 config radius account ing server add 7-60 config radius accounti ng server port 7-60 config radius accounti ng server remove 7-60 config radius accounti ng server secret 7-60 config radius maxretransmit 7-59 config radius server add 7-61 config radius server msgauth 7-62 co[...]
-
Page 153
Index 3 port detailed 7-68 port maxrequests 7-67 port quietperiod 7-66 port reauthenabled 7-68 port reauthen ticate 7-65 port reauthperiod 7-67 port servertimeout 7-67 port stats 7-69, 7-70 port summary 7-68 port transmitperio d 7-67 show port users 7-73 summary 7-68 supptimeout 7-67 downloading data types, setting 7-77 file names, setting 7-77 fil[...]
-
Page 154
4 Index adddest 7-45 addsrc 7-44 create 7-43 deldest 7-45 delsrc 7-44 remove 7-44 show 7-43 Management Access 2-1 management commands 201 commands 7-13 to 7-22 MDI/MDI-X 10-2 MDI/MDI-X wiring 10-1 1 mfdb gmrp 7-40 igmpsnooping 7-41 staticfiltering 7-41 stats 7-42 table 7-40 mirroring create 7-42 delete 7-43 mode 7-43 show 7-42 msg log displaying 7-[...]
-
Page 155
Index 5 server stats 7-63 server summary 7-62 stats 7-65 summary 7-62 timeout 7-59 reset system command 7-79 root traps 7- 21 routing default router IP address, setting 7-16 S save config command 7-58, 7-7 4 Security Commands 7-58 security commands 7-58 to 7-74 serial communication settings 7-15, 7-16 service port configuration 201 commands 7-16 se[...]
-
Page 156
6 Index show sysinfo 7-2 show telnet 7-22 show trapflags 7-20 show traplog 7-12 show users 7-56 show users authentication 7-74 show vlan detailed 7-29 show vlan interface 7-32 show vlan summary 7-29, 7-5 5 SNMP 2-2 SNMP communiti es access rights 7-17 adding 7-18 client IP masks 7-18 deleting 7-18 information 7-17 IP address 7-18 status 7-19 SNMP t[...]
-
Page 157
Index 7 TFTP setting as download mode 7-76 setting as upload mode 7-74 timeouts forwardingdb 7-23 serial 7-16 TIP 4-2 topology change notification traps 7-21 transfer commands transfer download datatype 7-77 transfer download filename 7-77 transfer download mode 7-76 transfer download path 7-77 transfer download serverip 7-77 transfer download star[...]
-
Page 158
8 Index X XMODEM setting as download mode 7-76 setting as upload mode 7-74 Z ZT erm 4-2[...]