Newcon Optik DN310 manual

1
2
3
4
5
6
7
8
9
10

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Newcon Optik DN310, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Newcon Optik DN310 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Newcon Optik DN310. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Newcon Optik DN310 should contain:
- informations concerning technical data of Newcon Optik DN310
- name of the manufacturer and a year of construction of the Newcon Optik DN310 item
- rules of operation, control and maintenance of the Newcon Optik DN310 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Newcon Optik DN310 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Newcon Optik DN310, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Newcon Optik service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Newcon Optik DN310.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Newcon Optik DN310 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    13. QUALITY CERTIFICATE The DN 310 is suited for usage. Production date _____________________________ Serial number ______________________________ Quality control ________________________________ Purchase date ______________________________ Salesman __________________________________ Quality inspector ____________________ (Signatu re) NEWCON TM . 2[...]

  • Page 2

    IMPORTANT INFORMATION Read prior to activation You have just purchased a com plicated electronic device. To operate it properly, please read this m anual carefully . Here are some com m on precautions that m ust be noted. • NEVER di sassemble the unit. This d evic e cont ains high volt age, w hich m ay be hazardous to you r health! • NEVER aim [...]

  • Page 3

    10. TROUBLE SHOOTI NG ] The scope does not work. Check th at the batteries are in stalled properly . Check th e charge of the batteries. Replace if th ey are w eak. Do not use old batteries w ith n ew ones. The image does not appear in focus. Bring the ins pected object to the center of the im age. T urning the objective lens ring (10), and/or the [...]

  • Page 4

    BEF ORE USE CAREFULLY READ ALL THE INSTRUCTIONS! FAILURE TO OBEY THE INSTRUCTIO NS WILL VOID TH E WARRANTY. 1. BRIEF DESCRIPTIO N DN 310 Night V ision Scope is a modern, universal nig ht vision device desig ned for a wide range of activ ities from amateur to professional needs: • Nighttim e observ ation and hunting • Law enforcem ent and securi[...]

  • Page 5

    2. Rem ov e the rubber eyepiece g uard from the scope. 3. Set the ey epiece in the m edium position. 4. Screw the adapter ring with the cam era in an internal g roove of an eyepiece. 5. Switch on the dev ice and focus the assembled sy stem with the help of the objectives of the device and cam era. I f the imag e cannot be focused the camera with th[...]

  • Page 6

    3. TECHNICAL CHARACTERI STICS General Magni ficati on, x 2.8 (5.2*) 4.4 Field of view , degree 17 (9*) 10 Objective lens Focus leng th, m m 64 (128) 100 F-n um ber 1.2 1.5 Focus range 10 m to infinity Eyepiece Focus le ngth, mm 35 Eye R elief Distan ce, mm 45 Dioptre setting +3, -4 Mechanical characteris tics Overall dim ens ions , m m 225 x 82 x 7[...]

  • Page 7

    7. ADJUSTMENT OF THE SCOP E ON THE RIF LE Dimensions of the Reticule The dimensions listed below are g ood for shooting rang e of 100m. For a distance other than 100m the dimensions m ust be calculated accordingly in proportion. Focus l engt h of t he objectiv e lens , mm 64 100 Cross hair w idth - A , m m 17 11 Interv al - B, m 1.4 0.9 Before adju[...]

  • Page 8

    NOTE. In order to ensure the long est operation time of the dev ice and full power of the I R illum inator (using one set of batteries) it is recomm ended to use Alk aline batteries, which ensure the most stable performance. b. Testing of operation During the brig ht time of the day : Turn on the on/off switch (13). Lens cap (12) must be on. Direct[...]

  • Page 9

    1- body of the dev ice 2- adapter rail with 7/8’’ Weav er prism encomp assing : (All parts of the align men t are supplied by New con Optik). Installation of the device is performed as follows : - Check the elevation of the fastening screws (2), pulling the rail (3) to the body of the dev ice (1) above the upper surface of the rail. The height [...]

  • Page 10

    INSTALLATION RULES. a. Variant I – Adapter rail with Standard P rism type. Device is fixed with the help of the following parts: Front and rear feet (2, 3) are the standard feet with Standard prism (4), manufactured by the com panies that produce m ounts (for example, Ernst Apel Gm bH Germ any)). The m ount of Standard prism ty pe (4) and screws [...]