Go to page of
Similar user manuals
-
Binoculars
Newcon Optik LRB 7X50
10 pages 0.26 mb -
Binoculars
Newcon Optik LRM1500SPD
24 pages 0.81 mb -
Binoculars
Newcon Optik NV66-G2-4x
20 pages 0.45 mb -
Binoculars
Newcon Optik NVS 15
28 pages 0.94 mb -
Binoculars
Newcon Optik NVS 7-4X
24 pages 0.78 mb -
Binoculars
Newcon Optik NEWCON LRB 7X50
10 pages 0.27 mb -
Binoculars
Newcon Optik NEWCON Image Stabilizer SIB 16x50M
2 pages 0.04 mb -
Binoculars
Newcon Optik SIB 16X40
8 pages 0.46 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Newcon Optik LRB 4000CI, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Newcon Optik LRB 4000CI one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Newcon Optik LRB 4000CI. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Newcon Optik LRB 4000CI should contain:
- informations concerning technical data of Newcon Optik LRB 4000CI
- name of the manufacturer and a year of construction of the Newcon Optik LRB 4000CI item
- rules of operation, control and maintenance of the Newcon Optik LRB 4000CI item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Newcon Optik LRB 4000CI alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Newcon Optik LRB 4000CI, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Newcon Optik service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Newcon Optik LRB 4000CI.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Newcon Optik LRB 4000CI item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
10. QUALITY CERTIFICATE LRB 4000CI is suited for usage. Production date ____________________________ Serial number _____________________________ Device performance: Actual data Measured data Reflective object, m Non-reflective object, m Azimuth, ° Elevation, ° RS-232 interface Pass Quality Inspect or signature___________________ Purchase date ___[...]
-
Page 2
IMPORTANT INFORMATION Read prior to activation You have just purchased a complicated electronic device. To operate it properly, please read this manual carefully. Here are some comm on precautions that must be noted. • NEVER subject the unit to im pact while operati ng or being transported • NEVER transport the unit without the case • NEVER d[...]
-
Page 3
8. WARRANTY NEWCON OPTIK warrants this product against defects in material and workmanship for one year from the date of the original date of consumer's purchase, but no more than 18 months from the date of m anufacturing. If your Newcon product proves to be defective during this period, please bring the product securely packaged in its origin[...]
-
Page 4
CONTENTS 1. Brief description 2. Appearance of the device 3. Supplied accessories 4. Technical characteristics 5. Operation instructions 5.1. Preparing the device for operation 5.2. Measuring procedure 5.3. Mode switching procedure 5.4. Gating distance selection 5.5. Additional display information 5.6. Computer interconnectivity 5.7. Test modes 6. [...]
-
Page 5
6. STORAGE AND MAINTENANCE INSTRUCTIONS . Precautions: LRB is a sophisticated precision optical instrument equipped with electronics. Therefore, it should be handled with due care. • Keep your device away from direct sunlight, impacts, dust, moisture, and sudden changes of temperatures. • Do not keep the device at temperatures higher than 65 o [...]
-
Page 6
2. APPEARANCE OF THE DEVICE 1 – Eyepieces; 2 – Objective lens – receiving lens; 3 – Objective lens - emitting lens; 4 – Dioptric correctio n rings; 5 – Mo de button; 6 – Action button; 7 – B ody of the device; 8 – Rubber gri p Fig. 1 6 5.6. Computer interconnectivity The unit is equipped with standard RS-232 interface. The data is[...]
-
Page 7
There are four statistical qualifications of the reflected signal: • NO TARGET REFLECTION – when a steady reflected signal isn’t received. Numerical display shows four dashes at the distance displaying area; • TARGET REFLECTION LOW – when the number of steady received reflected signals is just enough to make acceptable conclusion about th[...]
-
Page 8
7 4. TECHNICAL CHARACTERISTICS 1. Optics Magnification, x Objective Lens, mm Exit Pupil Diameter, mm Field of View Type of Coating Interpupilary distance, mm Diopter adjustment range Axial Resolution, ” Image tilt, maximum - Horizontal - Vertical 7 50 7.1 5 ° Fully multi-coated optics 58-72 ±4 6 60” 30” 2. Range Finder Type Measuring Range,[...]
-
Page 9
M/° - units of angular measurement: m ils or degrees Shape of the reticle: cross shape or rectangular shape (2). rEC1 - recall function. Upon pressing the Action button (6) (fig. 1) the Display will sequentially show results of last 10 measurements, starting from the latest one. The number appearing after word " rEC " shows the number of[...]
-
Page 10
5. OPERATION INSTRUCTIONS Liquid Crystal Display (LCD) 1 – Low battery indicat or; 2 – Reticle (cross or rectangular selectable); 3 – Units of measurem ent (Yards, Mete rs, KMH, MPH, Mils or Degrees); 4 – Measur ement result; 5 – Target quality ind icator; 6 – Laser active ind icator 7 – Over 100m gating i ndicator, 8 – Setup m ode [...]
-
Page 11
override reticle type and target selection with the sub selection code. For example, Standard 1 mode im plies cross reticle. If you choose rectangular reticle (sub selection code 10), you change the reticle shape and leave all ot her parameters of this mode intact. If then you choose Standard1 again, the reticle will turn back crosshair. The last s[...]
-
Page 12
The mode selection logic allows choosing the nearest (‘first’), the farthest (‘last’) or the most reflective (‘auto’) target. Besides, you can exclude all targets that are closer than the predefined distance (gating distance selection, see below). 5.3. Mode switching procedure By pressing M button (5) (Fig.1) when the System is in READY[...]
-
Page 13
Fig.4 Mode switching trek Mode Screen display Dis t anc e Spee d H orizontal Angl e Ver t ic al Angl e Ret ic le Tar get Typ e 1) Standar d 1 M Select this mode Go to next mode A , , , Meter Degree Degree 1) Standard 2 M Go to next mode A , , , Meter Mills Mills Codes 3) A M Go int o sub menu Code 1 A M Meter Code 2 A M Go to next mode Yard Code 3 [...]