Vacuum Cleaner
NuTone CV570
23 pages 1.36 mb -
Vacuum Cleaner
NuTone CT350B
32 pages 3.25 mb -
Vacuum Cleaner
NuTone UPC# 784891983535
1 pages 1.46 mb -
Vacuum Cleaner
NuTone VX550C
1 pages 1.03 mb -
Vacuum Cleaner
NuTone CV554
23 pages 1.36 mb -
Vacuum Cleaner
NuTone CH615
32 pages 3.25 mb -
Vacuum Cleaner
NuTone AB0008
16 pages 2.14 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of NuTone CV554, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of NuTone CV554 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of NuTone CV554. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of NuTone CV554 should contain:
- informations concerning technical data of NuTone CV554
- name of the manufacturer and a year of construction of the NuTone CV554 item
- rules of operation, control and maintenance of the NuTone CV554 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of NuTone CV554 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of NuTone CV554, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the NuTone service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of NuTone CV554.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the NuTone CV554 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Built-In Central Cleaning System MODELS: CV554, CV556, and CV570 SYSTEM PLANNING AND LAYOUT . . . . . . . . . . . . . . . . . . . . . . 2 Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Locating the Power Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Tubing and Wall Inlet L[...]
-
Page 2
2 SYSTEM PLANNING AND LA YOUT The Nu T one Central Cleaning System consists of a Power Unit, PVC Tubing and Fittings, Wall Inlets, a flexible Hose and various cleaning Attachments. The Power Unit is designed to be wall-mounted away from the living area of the home and connected to the living area by means of permanently installed in-wall tubing, fi[...]
-
Page 3
3 • Locate the power unit away from the general living area in an accessible location for emptying the lower dirt cannister and periodically cleaning the filter. • When planning, remember the power unit is equipped with an inlet to service a garage, basement, utility room, etc., wherever it is located. • Locate the power unit within six feet [...]
-
Page 4
4 INST ALLA TION IN NEW CONSTRUCTION Once the locations for wall inlets have been determined, mount all inlet brackets. 1. Choose the appropriate mounting bracket for the inlet being installed. (See chart.) 2. To locate bracket on wall stud, measure approximately 18" up from finished floor level. (Height may vary according to individual prefer[...]
-
Page 5
5 INST ALLA TION IN NEW CONSTRUCTION (continued) Use the following installation guidelines when installing tubing. 1. Start tubing installation at farthest inlet and work toward the power unit. 2. Tubing run to the power unit should be as straight as possible. 3. When assembling sections with elbows and tees, make sure the curve in the fitting is a[...]
-
Page 6
6 INST ALLA TION IN NEW CONSTRUCTION (continued) FIGURE 19 FIGURE 21 MODEL 365 DOUBLE FLANGED TEE W ALL INLET MOUNTING BRACKET SHORTEN W ALL FIGURE 17 MODEL 360 WALL INLET (361 Rough-In) 1. Remove the cardboard plaster guard. 2. Refer to Figure 17. For some drywall or panel construction, the plaster frame will extend beyond the finished wall. In th[...]
-
Page 7
7 INST ALLA TION IN NEW CONSTRUCTION (continued) 1. See Figure 23. Fasten the mounting plate to a stud within three studs (48") of an electrical outlet box. Measure and mark the wire 10" from the plug (A). Feed the wire through the top hole in the mounting plate (just above the circular opening). Snap the molded plug into the mounting pla[...]
-
Page 8
8 1. Use black rubber connectors and hose clamps to connect intake and exhaust tubing. 2. Connect intake tubing to intake tube on power unit. 3. Connect exhaust tubing to upper exhaust tube on power unit. 4. Make sure all tubing connections are securely fastened. 5. An optional muffler (Model 392) may be installed to reduce motor noise. 6. The exha[...]
-
Page 9
9 Use the following procedures for installation in existing construction. Starting from farthest wall inlet location, install each inlet as described below. Working back toward power unit, connect each inlet line and branch line into main trunk line. See page 5. Complete low voltage wiring as main trunk line is continued back to power unit. Mount p[...]
-
Page 10
10 INST ALLA TION IN EXISTING CONSTRUCTION (continued) MOUNTING PLA TE MOUNTING HOLE (2) ELBOW FIGURE 36 MOUNTING PLA TE INLET FIGURE 37 1. Make cutout according to dimensions in Figure 34. 2. Refer to Figure 35. Break off nail plate at scored line. 3. Refer to Figure 36. Glue elbow to mounting plate, place assembly into cutout, and attach elbow to[...]
-
Page 11
11 FLOOR INLET INST ALLA TION FLOOR SUB-FLOOR 2 9 / 16 " 3 1 / 16 " INLET EXTENSION FLOOR INLET FRAME MOUNTING BRACKET SEAL FLANGED FITTING FIGURE 40 CUT TO LENGTH EXTENSION SLEEVE FLANGED FITTING MOUNTING BRACKET FLANGE FIGURE 41 W ALL INLET EXTENSION SLEEVE BRACKET FLANGED FITTING TUBING FIGURE 42 FINAL SYSTEM CHECK Be sure all inlets a[...]
-
Page 12
Systè me Central PLANIFICATION ET DISPOSITION DU SYSTEME . . . . . . . . . . . 2 Exemples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Emplacement du Groupe d’Aspiration . . . . . . . . . . . . . . . . . . . . . .3 Tuyauterie et Emplacement des Prises Murales . . . . . . . . . . . . . .3 Emplacement de[...]
-
Page 13
2 PLANIFICA TION ET DISPOSITION DU SYSTEME Le système central d'aspiration intégré de NuTone comprend un groupe d'aspiration, une tuyauterie et des raccords en PVC, des prises d'aspiration murales, un tuyau souple et de différents accessoires de nettoyage. Le Groupe d'Aspiration est conçu pour un montage mural éloigné de [...]
-
Page 14
3 • Installez le groupe d’aspiration à l’écart de la zone habitée, à un endroit facile d’accès pour le nettoyage du filtre et la vidange du bac à saleté. • Lors de votre planification, rappelez-vous que le groupe d'aspiration est équipé d'une prise pour vous servir dans le garage, le sous-sol, la buanderie, etc., où qu[...]
-
Page 15
4 INST ALLA TION DANS UNE NOUVELLE CONSTRUCTION Une fois l'emplacement des prises murales déterminé, mettez en place tous les supports de prise. 1. Choisissez les supports de fixation appropriés pour la prise à installer. (Voyez le tableau). 2. Pour positionner le support sur le montant, mesurez approximativement 45,7 cm au-dessus du nivea[...]
-
Page 16
5 INST ALLA TION DANS UNE NOUVELLE CONSTRUCTION (suite) Suivez les lignes directrices ci-dessous lors de la mise en place de la tuyauterie. 1. Commencez l'installation de la tuyauterie par la prise la plus éloignée et avancez vers le groupe d'aspiration. 2. La tuyauterie qui rejoint le groupe d'aspiration devrait être la plus droi[...]
-
Page 17
6 INST ALLA TION DANS UNE NOUVELLE CONSTRUCTION (suite) FIGURE 19 FIGURE 21 MODEL 365 DOUBLE FLANGED TEE W ALL INLET MOUNTING BRACKET SHORTEN W ALL FIGURE 17 MODELE 360 PRISE MURALE (ENCASTREMENT 361) 1. Enlevez le carton du cadre protecteur. 2. Voyez la figure 17. Pour certaines cloisons sèches ou constructions à panneaux, le cadre va s'ete[...]
-
Page 18
7 INST ALLA TION DANS UNE NOUVELLE CONSTRUCTION (suite) 1. Voyez la figure 23. Attachez la plaque de montage à un montant à une distance maximum de trois montants (1,22 m) d'un coffret de sortie électrique. Mesurez et marquez le câble à 25,4 cm de la prise (A). Avancez le câble à travers le trou du haut de la plaque de montage juste au-[...]
-
Page 19
8 1. Utilisez des raccords de caoutchouc noir et des brides pour connecter les conduites d'arrivée et d'évacuation. 2. Raccordez la conduite d'arrivée à l'entrée du groupe d'aspiration. 3. Raccordez la conduite d'évacuation à l'échappement supérieur du groupe d'aspiration. 4. Assurez-vous que tous le[...]
-
Page 20
9 Utilisez les procédures suivantes pour une installation dans une construction existante. En commençant par la prise murale la plus éloignée, installez chaque prise tel qu' il vous est décrit ci-dessous. Travaillez vers le groupe d'aspiration; connectez chaque ligne de prise et ligne secondaire à la ligne principale. Voyez la page [...]
-
Page 21
10 INST ALLA TION DANS UNE CONSTRUCTION EXIST ANTE (suite) MOUNTING PLA TE MOUNTING HOLE (2) ELBOW FIGURE 36 MOUNTING PLA TE INLET FIGURE 37 1. Faites la découpe en accord avec les dimensions de la Figure 35. 2. Voyez la Figure 36. Détachez la plaque suivant les pointillés. 3. Voyez la Figure 37. Collez le coude à la plaque de montage, placez l[...]
-
Page 22
11 INST ALLA TION DES PRISES AU SOL FLOOR SUB-FLOOR 2 9 / 16 " 3 1 / 16 " INLET EXTENSION FLOOR INLET FRAME MOUNTING BRACKET SEAL FLANGED FITTING FIGURE 40 CUT TO LENGTH EXTENSION SLEEVE FLANGED FITTING MOUNTING BRACKET FLANGE FIGURE 41 W ALL INLET EXTENSION SLEEVE BRACKET FLANGED FITTING TUBING FIGURE 42 VERIFICA TION FINALE DU SYSTEME A[...]
-
Page 23
4820 Red Bank Road, Cincinnati, Ohio 45227 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9 www.nutone.com T wo Y ear Limited W arranty WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of two (2) years from the date of ori[...]