The rules should oblige the seller to give the purchaser an operating instrucion of Omega Engineering OS1592, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omega Engineering OS1592 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omega Engineering OS1592. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omega Engineering OS1592 should contain:
- informations concerning technical data of Omega Engineering OS1592
- name of the manufacturer and a year of construction of the Omega Engineering OS1592 item
- rules of operation, control and maintenance of the Omega Engineering OS1592 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omega Engineering OS1592 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omega Engineering OS1592, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omega Engineering service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omega Engineering OS1592.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omega Engineering OS1592 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OS1592 Infrared Fiber Optic Thermometer/T ransmitter MADE IN omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info Shop online at U ser ’ s Guide[...]

  • Page 2

    Servicing Nor th America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canad[...]

  • Page 3

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal two (2) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s custo[...]

  • Page 4

    T ABLE OF CONTENTS SECTION ..................................................................P AGE Section 1 Introduction ........................................................................ 1 Section 2 Installation ........................................................................... 1 2.1 Unpacking ......................................[...]

  • Page 5

    T ABLE OF FIGURES FIGURE ..................................................................P AGE 1 OS1592 Main Unit ............................................................................ 3 2 Power Supply and Analog Output Connections ........................... 3 3 V isual Functional Flow Chart ................................................[...]

  • Page 6

    INTRODUCTION The new OS1592 series Infrared Fiber Optic Thermometer/T ransmitter provides non-contact temperatur e measurement for industrial applications. The unit measures temperatur e starting at 260°C (500°F) and up to 2482°C (4500°F). It provides dual analog outputs (4-20 mA, 0-5 VDC, 0-10 VDC, 1 mV/Deg, J & K type T/Cs) electrically i[...]

  • Page 7

    The following describes the ordering information: The unit provides two separate analog outputs. The first is 1mV/Deg (Standard). The second analog output to be specified as follows : - * , where, - mA , 4-20 mA output - V1, 0/5 VDC output - V2, 0/10 VDC output - K, Thermocouple output, K type (For R1 & R2 T emperature range only) - J , Thermoc[...]

  • Page 8

    2.2 – Electrical Connection Attach the optical assembly to the optical adapter located on the side of the housing. Refer to Fig. 1 for the overall appearance of the unit. Open the cover of the aluminum housing. Slide your cable through the metal feed thru and connect the wir es to the 9 position terminal block (J101) as shown in Fig. 2. Depending[...]

  • Page 9

    OPERA TION T able 1 shows all the display modes of the model OS1592, as well as all the functions of the membrane keypad. Fig 3 shows the V isual Functional flow chart of the display . Table 1 - Functional Flow Chart Figure 3 - Visual Functional Flow Chart OS1592 Infrared Fiber Optic Thermometer/T ransmitter 3 4 DISPLA Y MODE: Press to... Go to Go [...]

  • Page 10

    The Emissivity setting as well as the temperature Engineering unit (°F or °C) are stored in the non-volatile memor y . Removing the main power will not erase or change these settings. 3.1 - Changing the T emperature from °F to °C (or vice versa) Press the key to go to either the MAX , MIN, or DIF display mode. Press the key to change the temper[...]

  • Page 11

    0-5VDC: Measured T emp = [ ( V oltage Output ) x (T2 - T1) ] + T1 5 0-10VDC: Measured T emp = [ ( V oltage Output ) x (T2 - T1) ] + T1 10 Where, T1 is the minimum temperature range T2 is the maximum temperature range 3.5 - Resetting T emperature V alues The calculated temperature values (Min, Max, and Dif f) can be reset at any time by pressing the[...]

  • Page 12

    Figure 5 - Optical Lens Assembly (L1) .25" @ 8" FOV Figure 6 - Optical Lens Assembly (L1) .19" @ 20" FOV Figure 7 - Optical Lens Assembly (L1) .076" @ 6" FOV Figure 8 - Ceramic Tip Assembly (L2) OS1592 Infrared Fiber Optic Thermometer/Transmitter 3 7 111 (4.38) 159 (6.25) Dimensions mm (in.) FIBER 19 (.75) DIA. 25.4 (1[...]

  • Page 13

    Figure 9 - Polymer Bolt Assembly (L3) with 90° Angle Air Purge Fitting Figure 10 - Optical Head, Mounting Bracket OS1592-MB Figure 11 - Air Purge Collar OS1592 Infrared Fiber Optic Thermometer/Transmitter 3 8 FIBER 72 (2.84) 53 ± 1.5 (2.10 ± 0.06) 12.7 ± 1.5 (.50 ± 0.06) 11 (0.438) 102 ± 1.5 4.00 ± 0.06 25.4 ± 1.5 (1.00 ± .06) FULL THREAD [...]

  • Page 14

    SPECIFICA TIONS T emperature Range R1 260 to 538°C (500 to 1000°F) R2 538 to 1093°C (1000 to 2000°F) R3 1093 to 2482°C (2000 to 4500°F) Accuracy at 22°C (72 °F) 1% of Rdg. ambient temperature and at Emissivity of 0.95 or greater Repeatability 0.5% of Rdg Resolution 1°C or 1°F Response T ime 25 msec (0 to 63% of Final value) Spectral Respo[...]

  • Page 15

    Display Backlit LCD dual display Keypad switch 4 position, tactile feed back membrane Electrical Isolation Between Input supply and Analog outputs, 1000 V AC Calculated T emperature Maximum (MAX), Minimum (MIN) values and Differ ential (DIF), Reset via keypad High Alarm LED & Display Icon indication Set & enabled via Keypad Alarm set point [...]

  • Page 16

    OS1592 Infrared Fiber Optic Thermometer/T ransmitter 5 11 MAINTENANCE Routine maintenance is not requir ed except for periodic re-calibration, occasional inspection of the input and output ends of the fiber assembly for cleanliness, and a check for broken fibers if damage is suspected. The optical fibers will provide satisfactory service indefinite[...]

  • Page 17

    OS1592 Infrared Fiber Optic Thermometer/Transmitter Addendum 12 Safety W arnings and IEC Symbols This device is marked with international safety and hazardous symbols in accordance with IEC1010. It is important to r ead and follow all the precautions and instructions in this manual befor e operating or commissioning this device as it contains impor[...]

  • Page 18

    M3672/0905 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Contr[...]