Omega Vehicle Security CCT-80 Series manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omega Vehicle Security CCT-80 Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omega Vehicle Security CCT-80 Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omega Vehicle Security CCT-80 Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omega Vehicle Security CCT-80 Series should contain:
- informations concerning technical data of Omega Vehicle Security CCT-80 Series
- name of the manufacturer and a year of construction of the Omega Vehicle Security CCT-80 Series item
- rules of operation, control and maintenance of the Omega Vehicle Security CCT-80 Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omega Vehicle Security CCT-80 Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omega Vehicle Security CCT-80 Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omega Vehicle Security service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omega Vehicle Security CCT-80 Series.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omega Vehicle Security CCT-80 Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    M2218/1201 http://www.omega.com e-mail: info@omega.com ® U ser ’ s Guide CCT -80 Strain Gage Signal Conditioners[...]

  • Page 2

    Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.com For immediate technical or application assistance: USA and Canada: Sales Service:[...]

  • Page 3

    NOTES T ABLE OF CONTENTS PAGE Open the Housing . . . . . . . . . . . . . . . . . . . . . . . . 3 Internal Overview . . . . . . . . . . . . . . . . . . . . . . . . 3 Power Supply module MA . . . . . . . . . . . . . . . . . . 4 Changing the Power Supply . . . . . . . . . . . . . . . . 4 Signal Output module MS . . . . . . . . . . . . . . . . . . 5 Ch[...]

  • Page 4

    PROCEDURE 1. Insert a screwdriver or similar tool in the points marked c . 2. Turn the screwdriver until the case walls begin to separate towards A and B , so the two side lugs e , are free. 3. Grab the Signal Conditioner body, at the points marked d ‚ and pull it towards C , until the two side lugs e are out of their housing and the internal cir[...]

  • Page 5

    - +10 Vdc FIG.10 350 Ω + - + - POWER SUPPLY The side label, shows the type and value of the power supply. SIGNAL OUTPUT Current SIGNAL OUTPUT Voltage POWER SUPPLY OUTPUTS / SALIDAS mA Vdc INPUT / ENT RADA SUPPL Y / ALIMENTA CION 3 4 5 6 9 10 11 12 7 1 + Lo H i + -- OUTPUTS SALI DAS A C VOLTAGE 3 4 5 6 1 2 POWER SUPPL Y FUENTE A LIMENTACION TARE A[...]

  • Page 6

    FIG.8 "MP" input board PT1 SIGNAL INPUT RANGE SELECTION The "MP" input board for this signal conditioner, does not have jumpers because it allows only one signal input (0 to 20 mV). To calibrate the signal conditioner, follow the adjustment and calibration procedure. The user can field adjust the tare using the trim- mer PT1, lo[...]

  • Page 7

    INPUT STANDARD SIGNAL 20 mV TARE by internal trimmer PT1, located on the "MP" input board OUTPUT 0 to 20 mA or 4 to 20 mA R L < 600 Ω max. 22 mA ±3% 0 to 10 Vdc R L > 1000 Ω max. 11 V ±3% ACCURACY ≤ 0.2 % FS RESPONSE TIME ≤ 250 mS GALVANIC ISOLATION Input, Output and Power Supply are all isolated to 2 kVeff . 50 Hz/1 m. GE[...]

  • Page 8

    INPUT STANDARD SIGNAL 20 mV TARE by internal trimmer PT1, located on the "MP" input board OUTPUT 0 to 20 mA or 4 to 20 mA R L < 600 Ω max. 22 mA ±3% 0 to 10 Vdc R L > 1000 Ω max. 11 V ±3% ACCURACY ≤ 0.2 % FS RESPONSE TIME ≤ 250 mS GALVANIC ISOLATION Input, Output and Power Supply are all isolated to 2 kVeff . 50 Hz/1 m. GE[...]

  • Page 9

    FIG.8 "MP" input board PT1 SIGNAL INPUT RANGE SELECTION The "MP" input board for this signal conditioner, does not have jumpers because it allows only one signal input (0 to 20 mV). To calibrate the signal conditioner, follow the adjustment and calibration procedure. The user can field adjust the tare using the trim- mer PT1, lo[...]

  • Page 10

    - +10 Vdc FIG.10 350 Ω + - + - POWER SUPPLY The side label, shows the type and value of the power supply. SIGNAL OUTPUT Current SIGNAL OUTPUT Voltage POWER SUPPLY OUTPUTS / SALIDAS mA Vdc INPUT / ENT RADA SUPPL Y / ALIMENTA CION 3 4 5 6 9 10 11 12 7 1 + Lo H i + -- OUTPUTS SALI DAS A C VOLTAGE 3 4 5 6 1 2 POWER SUPPL Y FUENTE A LIMENTACION TARE A[...]

  • Page 11

    PROCEDURE 1. Insert a screwdriver or similar tool in the points marked c . 2. Turn the screwdriver until the case walls begin to separate towards A and B , so the two side lugs e , are free. 3. Grab the Signal Conditioner body, at the points marked d ‚ and pull it towards C , until the two side lugs e are out of their housing and the internal cir[...]

  • Page 12

    NOTES T ABLE OF CONTENTS PAGE Open the Housing . . . . . . . . . . . . . . . . . . . . . . . . 3 Internal Overview . . . . . . . . . . . . . . . . . . . . . . . . 3 Power Supply module MA . . . . . . . . . . . . . . . . . . 4 Changing the Power Supply . . . . . . . . . . . . . . . . 4 Signal Output module MS . . . . . . . . . . . . . . . . . . 5 Ch[...]

  • Page 13

    WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers recei[...]

  • Page 14

    Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Thermocouple, RTD & Thermistor M U Calibrators & Ice Point References M U Recorders, Controllers & Process Monitors M U Infrared Pyrometers PRE[...]