Go to page of
Similar user manuals
-
Thermometer
Omega Vehicle Security HH508
20 pages 0.21 mb -
Thermometer
Omega Vehicle Security HHLM-2
13 pages 0.18 mb -
Thermometer
Omega Vehicle Security HH501BJ
12 pages 0.17 mb -
Thermometer
Omega Vehicle Security OS642F
16 pages 0.2 mb -
Thermometer
Omega Vehicle Security HH-21
31 pages 1.09 mb -
Thermometer
Omega Vehicle Security OS530 Series
2 pages 0.31 mb -
Thermometer
Omega Vehicle Security HH506
15 pages 0.18 mb -
Thermometer
Omega Vehicle Security OS643W
19 pages 0.19 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Omega Vehicle Security CL3512A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omega Vehicle Security CL3512A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Omega Vehicle Security CL3512A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Omega Vehicle Security CL3512A should contain:
- informations concerning technical data of Omega Vehicle Security CL3512A
- name of the manufacturer and a year of construction of the Omega Vehicle Security CL3512A item
- rules of operation, control and maintenance of the Omega Vehicle Security CL3512A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omega Vehicle Security CL3512A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omega Vehicle Security CL3512A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omega Vehicle Security service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omega Vehicle Security CL3512A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Omega Vehicle Security CL3512A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
CL3512A CL3512A CL3512A CL3512A CL3512A Digital Thermometer & Calibrator Digital Thermometer & Calibrator Digital Thermometer & Calibrator Digital Thermometer & Calibrator Digital Thermometer & Calibrator[...]
-
Page 2
OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail info@omega.com Servicing North America: USA: ISO 9001 Certified Canada: One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 Laval (Quebec) H7L5A1 Tel: (203) 359-1660 Tel: (514) 856-6928 FAX: (203)359-7700 FAX: (514) 856-6886 e-mail: info@omega.com e-mail: info@omega.com omega[...]
-
Page 3
Table of contents 1.0 Introduction 1.1 Safety Information 1.2 Unpacking 2.0 Operation Procedure 2.1 Unit Drawing 2.2 Description of Buttons and Switches 2.3 Read Mode Procedure 2.4 Source Mode Procedure 3.0 Operator Maintenance 4.0 Specifications 5.0 Calibration Procedure[...]
-
Page 4
1 1.0 Introduction The OMEGA ® CL3512A calibrator/thermometer is two meters in one. The CL3512A simulates type J/K/T/E thermocouple signals. Each signal is adjustable by using the coarse and fine dials. The CL3512A can also be used as a dual type J/K/T/E thermocouple input thermometer. Features include a large 3½ digit display with backlighting a[...]
-
Page 5
2 1.2 Unpacking Remove the packing list and verify that all equipment has been received. If there are any questions about the shipment, please call the OMEGA Customer Service Department. Upon receipt of shipment, inspect the container and equipment for any signs of damage. Immediately report any damage to the shipping agent. NOTE The carrier will n[...]
-
Page 6
2.0 Operation Proceedure 2.1 Drawing of Unit 3 Actual Dimensions: 195mm(H) x 92mm(W) x 53mm(D)[...]
-
Page 7
4 2.2 Descriptions of Buttons and Switches / Buttons Temperature is displayed in either degrees Celsius(°C) or degrees Fahrenheit(°F). When the thermometer is turned on, it is set to the temperature scale that was in use when the thermometer was last turned off. To change the temperature scale, press the °C or °F key. Button Press " "[...]
-
Page 8
5 / / Input Selections The input selection indicates which input is selected; T1 thermocouple, T2 thermocouple or the difference between the two thermocouples (T1-T2).When the thermometer is turned on, it is set to the temperature input that was in use when the thermometer was last turned off. Selector Switch The circular selector switch is used to[...]
-
Page 9
6 2.3 Read Mode Proceedure 1. Plug Thermocouple Sensor into input T1 and/or T2. 2. Turn selector switch to Input. 3. Select proper thermocouple type (J, K, T or E) using type button. 4. Press T1 button to read thermocouple connected to input T1. Press T2 button to read thermocouple connected to input T2. Press T1-T2 if difference between T1 and T2 [...]
-
Page 10
7 2.4 Source Mode Procedure (Calibration Simulation) 1. Turn CL3512A on by turning selector switch to any one of the output selector positions. 2. Press T1 button. 3. Select thermocouple type (J, K, T or E) using type button. Select °C or °F using °C or °F buttons. 4. Plug proper type of thermocouple wire into either one of the two output conne[...]
-
Page 11
Source Mode Diagram 8[...]
-
Page 12
9 3.0 Operator Maintenance WARNING To avoid possible electrical shock, disconnect the thermocouple connectors from the thermometer before removing the cover. Battery Replacement Power is supplied by a 9 volt "transistor" battery. The " " appears on the LCD display when replacement is needed. To replace the battery, remove the tw[...]
-
Page 13
10 4.0 Specifications ELECTRICAL Temperature Scale: Celsius or Fahrenheit user-selectable Measurement Range: Thermocouple Range K-TYPE(0.1°C) -200°C to 1372°C , -328°F to 1999°F J-TYPE(0.1°C) -210°C to 1200°C , -346°F to 1999°F T-TYPE(0.1°C) -200°C to 400°C , -328°F to 752°F E-TYPE(0.1°C) -220°C to 1000°C , -364°F to 1832°F Cali[...]
-
Page 14
GENERAL Display: 3½ digit liquid crystal display (LCD) with a maximum reading of 1999. Polarity: Automatic,positive implied,negative polarity indication. Overrange: -OL is displayed. Zero: Automatic. Low battery indication: the" "is displayed when the battery voltage drops below the operating level. Measurement rate: 1 times/second. Accu[...]
-
Page 15
5.0 CL3152A Calibration Procedure Note: The following calibration procedure should be performed only by qualified technicians who have access to the items as following items: Equipment: 1) A very accurate millivolt source. 2) A TRC III ICE Point Reference or ice bath with type K thermocouple. Input Funtion "Calibration" 1. Before turning [...]
-
Page 16
13 "Simulated Output" Test 1. Turn the knob "COARSE" right to the end, knob of RANGE turn right to the last two position, press "TYPE" key to select "TYPE-E", if display does not show "OL" then adjust VR4 slowly to make display ="OL" (Note: Take care not to adjust VR4 too far) .[...]
-
Page 17
1 CL3512A CA LIBRA TION PROCEDURES Note: The following calibration procedure s hould perform only by qualified technicians who have access to the items as fol lowing. Equipment: The class of calibrator ha d better 10 times g reater than the measur ed meter. INPUT FUNTI ON C ALI BR ATE 1. Before turn on the meter, turn the R ANGE knob to position &q[...]
-
Page 18
WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of def ects in mater ials and workmanship f or a period of 13 months from date of purchase. OMEGA W arranty adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cov er handling and shipping time. This ensures that OMEGA's custom[...]
-
Page 19
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERATURE " Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies " Wire: Thermocouple, RTD & Thermistor " Calibrators & Ice Point References " Recorders, Controllers & Process Monitors " Infrared[...]