Go to page of
Similar user manuals
-
Electric Heater
Omega Vehicle Security SH73343
4 pages 0.48 mb -
Electric Heater
Omega Vehicle Security DRF-RES Series
12 pages 0.36 mb -
Electric Heater
Omega Vehicle Security SSHB
5 pages 0.33 mb -
Electric Heater
Omega Vehicle Security KH
4 pages 0.23 mb -
Electric Heater
Omega Vehicle Security KHLV Series
4 pages 0.23 mb -
Electric Heater
Omega Vehicle Security LSC6400
6 pages 1.26 mb -
Electric Heater
Omega Vehicle Security KHR
4 pages 0.23 mb -
Electric Heater
Omega Vehicle Security OM5-C
56 pages 0.73 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Omega Vehicle Security DRF-POT, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omega Vehicle Security DRF-POT one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Omega Vehicle Security DRF-POT. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Omega Vehicle Security DRF-POT should contain:
- informations concerning technical data of Omega Vehicle Security DRF-POT
- name of the manufacturer and a year of construction of the Omega Vehicle Security DRF-POT item
- rules of operation, control and maintenance of the Omega Vehicle Security DRF-POT item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omega Vehicle Security DRF-POT alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omega Vehicle Security DRF-POT, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omega Vehicle Security service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omega Vehicle Security DRF-POT.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Omega Vehicle Security DRF-POT item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info Shop online at DRF-POT FOR POTENTIOMETER INPUT , DRF-RES FOR RESIST ANCE INPUT DRF Series Signal Conditioners U ser ’ s Guide[...]
-
Page 2
OMEGAnet ® On-Line Service Internet e-mail omega.com info@omega.com It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certi[...]
-
Page 3
Page 3 User’s Manual DRF Series INDEX GENERAL INFORMATION .................................................. 4 QUICK GUIDE .................................................................... 5 POWER SUPPLY CONNECTIONS ................ 5 SIGNAL ADJUSTMENT .................................. 6 and 7 DIMENSIONS AND CONNECTIONS .............. 8 TECHN[...]
-
Page 4
Page 4 User’s Manual DRF Series GENERAL INFORMATION The DRF series of Isolated Signal Converters, allow to convert process signals, temperatures, electrical signals, etc, to current loops or voltage signals for further retransmision, while introducing into the system galvanic isolation barriers between the input, the output and the power supply c[...]
-
Page 5
Page 5 User’s Manual DRF Series QUICK GUIDE The DRF units have a front cover which can be opened down. This cover gives access to the Span and Offset potentiometers, and to the selection jumpers for input and output signal ranges. To open the front cover, press slightly the sides of the cover at the upper side, close to the OUTPUT terminals, as i[...]
-
Page 6
Page 6 User’s Manual DRF Series SIGNAL ADJUSTMENT To proceed to adjust a range of input and output signals, first select with the appropriate jumpers, the signal ranges Adjustment Example for model DRF-POT 1.- Connect potentiometer to input terminals (8 «term+», 9 «term-» and 7 «signal») 2.- Connect a multimeter to the output signal termina[...]
-
Page 7
Page 7 User’s Manual DRF Series S ELECTION J UMPERS : I NPUT S IGNAL R ANGE Range : 100% FS Range : 25% FS Range : 50% FS Range : 3 KOhms Range Min : 1.5 KOhms Range : 1.5 KOhms Range Min : 750 Ohms Range : 5 KOhms Range Min : 3 KOhms Range : 10 KOhms Range Min : 5 KOhms DRF-POT for POTENTIOMETER SIGNALS Range : 12.5% FS DRF-RES for RESISTANCE SI[...]
-
Page 8
Page 8 User’s Manual DRF Series Input Connections POTENTIOMETER RESIST ANCE 9mm (0.35’’) 93mm (3.66’’) 24 Vdc ~ 0 Vdc ~ 110 mm (4.33’’) DIMENSIONS AND CONNECTIONS S pecial Width for AC Power models AC Powered DC Powered Output Connections 37mm (1.46’’) 22,5mm (0.89’’)[...]
-
Page 9
Page 9 User’s Manual DRF Series INPUT SIGNAL for POTENTIOMETER RANGES 0/100 % 0/50 % 0/25 % 0/12.5% (minimum 8%) Potentiometer value min 100Ohms max 1MOhm 3 Wire System, 1 Vdc Excitation INPUT SIGNAL in RESISTANCE RANGES 0/10 KOhms 0/5 KOhms 0/3 KOhms 0/1.5 KOhms (minimum 750 Ohms) 2 Wire System, 0.2 mA Excitation OUTPUT SIGNAL in VDC RANGES 0/10[...]
-
Page 10
Page 10 User’s Manual DRF Series INSTALATION PRECAUTIONS.- The installation and the future use of this unit must be done by qualified personnel. The unit has not AC (mains) switch, neither internal protection fuse. It will be in operation as soon as power is connected. The installation must incorporate an external mains switch with a protection f[...]
-
Page 11
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repa[...]
-
Page 12
Where Do I Find Everything I Need for Process Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com M4138/0305 TEMPERATURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Controll[...]