Go to page of
Similar user manuals
-
Switch
Omega Vehicle Security PSW490B
8 pages 0.83 mb -
Switch
Omega Vehicle Security PSW790B
8 pages 0.83 mb -
Switch
Omega Vehicle Security FSW-420
3 pages 0.34 mb -
Switch
Omega Vehicle Security PSW18H Seriers
8 pages 0.09 mb -
Switch
Omega Vehicle Security LV-1203
8 pages 0.34 mb -
Switch
Omega Vehicle Security LV-1202
8 pages 0.34 mb -
Switch
Omega Vehicle Security 430
3 pages 0.34 mb -
Switch
Omega Vehicle Security LVUN-600
16 pages 0.2 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Omega Vehicle Security LVP-51 Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omega Vehicle Security LVP-51 Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Omega Vehicle Security LVP-51 Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Omega Vehicle Security LVP-51 Series should contain:
- informations concerning technical data of Omega Vehicle Security LVP-51 Series
- name of the manufacturer and a year of construction of the Omega Vehicle Security LVP-51 Series item
- rules of operation, control and maintenance of the Omega Vehicle Security LVP-51 Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omega Vehicle Security LVP-51 Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omega Vehicle Security LVP-51 Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omega Vehicle Security service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omega Vehicle Security LVP-51 Series.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Omega Vehicle Security LVP-51 Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Where Do I Find Everything I Need for Process Measurement and Contr ol? OMEGA…Of Course! TEMPERA TURE 䡺 ⻬ Thermocouple, RTD & Thermistor Pr obes, Connectors, Panels & Assemblies 䡺 ⻬ W ire: Thermocouple, R TD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Controllers & Pr ocess Monitors 䡺 ?[...]
-
Page 2
Step One SPECIFICA TIONS T echnology: The non-intrusive RF capacitance switch detects the pres- ence of liquid or air by measuring the conductive or dielec- tric values which are present in all materials. An electrical capacitor is formed between the level switch and the outer tank wall. As liquid rises and falls against the inner wall, the capacit[...]
-
Page 3
Step T wo Step Three SAFETY PRECAUTIONS INTRODUCTION About this Manual: PLEASE READ THE ENTIRE MANUAL PRIOR TO INST ALLING OR USING THIS PRODUCT . This manual includes information on all models of the L VP-51 series Non- Intrusive RF Capacitance level switch from Omega. Please refer to the part number located on the switch label to verify the exact[...]
-
Page 4
Step Four Step Five INST ALLA TION ELECTRICAL OMEGA's L VP-51 series level switch may be installed anywhere on a tank wall using the supplied PE fitting that the switch slides into. The fitting comes with adhesive on the tank side that is sufficient to hold the sensor in position temporarily while the installation is tested, but for permanent [...]
-
Page 5
Step Six Step Seven WIRING WIRING Wiring to a Omega Controller L VCN-120/-130/-140 Series Controller: Blac k Shield White and Green - Not Used Red + - - + - - INVER T INVER T DELA Y DELA Y POWER RELA Y 1 RELA Y 2 INPUT 1 INPUT 2A INPUT 2B LA TCH ON OFF Wiring as a P-Channel or N-Channel output: The L VP-51 series can be substituted for either a P-C[...]
-
Page 6
Step Eight Step Nine CALIBRA TION CALIBRA TION After it is installed in place, the L VP-51 series must be calibrated by the user before operation. Everything needed for the procedure is self-con- tained within the electronics of the L VP-51 series level switch. T wo dielectric states—full condition and empty condition—are measured by the L VP-5[...]