A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omega FPDM1000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omega FPDM1000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omega FPDM1000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omega FPDM1000 should contain:
- informations concerning technical data of Omega FPDM1000
- name of the manufacturer and a year of construction of the Omega FPDM1000 item
- rules of operation, control and maintenance of the Omega FPDM1000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omega FPDM1000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omega FPDM1000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omega service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omega FPDM1000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omega FPDM1000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    FPDM1000 SERIES Positive Displacement Mechanical Flowmeters[...]

  • Page 2

    [...]

  • Page 3

    Please read this information carefully befor e use! Before use, confirm the fluid to be used is compatible with the meter or consult with OMEGA for advice. To prevent damage fr om dirt or foreign matter , OMEGA recommends a Y or bas- ket type 60 mesh strainer be installed as close as possible to the inlet side of the meter . (If requir ed, contact [...]

  • Page 4

    1. OMEGA recommends that when set- ting up pipework for meter installations, a bypass line be included in the de- sign. This provides the facility for a meter to be removed for maintenance without interrupting production. (See Figure 1) 2 NOTE: Incorrect installation can cause pr e- mature wear of meter components 7. Do not overtighten meter connec[...]

  • Page 5

    3 OPERA TION SERVICE INSTRUCTIONS When fluid passes through the meter , the ro tors tur n. The gear located on top of one of the rotors drives the mechanical r egis- ters gear train which provides an accurate r eadout. Figure 3 Rotor #2 Rotor #1 Rotors must be at 90 ° to each other Disassembly: Ensure that the fluid supply to the meter is disconne[...]

  • Page 6

    4 Check rotor operation by turning either of the rotors. If the r otors are not in mesh correctly or do not move fr eely , remove one of the rotors and r eplace it correctly at 90 degrees to the other r otor . Recheck the operation of the rotors. 4. Inspect the gears in the meter cap for wear . Replace if requir ed - refer to spar e parts on page 6[...]

  • Page 7

    5 Symptom Probable Cause Corrective Action FLUID WILL NOT 1. Foreign matter blocking Dismantle meter , clean rotors. Strainer must FLOW THROUGH rotors be fitted in-line. THE METER 2. Line strainer blocked Clean strainer . 3. Damaged rotors Replace rotors. Strainer must be fitted in-line. 4. Meter connections over - Re-adjust connections. tightened [...]

  • Page 8

    6 4 3 2 1 20 * 21 * 7 10 11 13 12 14 15 16 17 8 / 9 8A / 9A O-Ring Only 5 6 METER P ARTS LISTING Model: FPDM1004 Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS298N Meter Body 1/2 in. NPT (Aluminum) 11 MS337N Meter Body 1/2 in. NPT (Stainless Steel) 21 u BS145TES O-Ring (T eflon ® ) 21 u BS145VS O-Ring ([...]

  • Page 9

    7 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 1 to 30 / 0.26 to 8 Below 5 centipoise 3 to 25 / 0.8 to 6.6 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e 3450 kPa / 500 PSI / 34.5 Bar Operating T emperature Range -10 ° C to 80 ° C (+14 ° F to +176 ° F) * Unless hi[...]

  • Page 10

    8 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS188N Meter Body 1 in. NPT (Aluminum) 11 MS186N Meter Body 1 in. NPT (Stainless Steel) 11 MS188F Meter Body 1 in. ANSI 150 lb. Flange (Aluminum) 11 MS186F Meter Body 1 in. ANSI 150 lb. Flange (S/Steel) 21 u BS235TES O-Ring (T eflon ® ) [...]

  • Page 11

    9 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 6 to 120 / 1.6 to 32 Below 5 centipoise 10 to 100 / 2.6 to 26 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e 3450 kPa / 500 PSI / 34.5 Bar or Flange Rule Maximum Operating T emperature 80 ° C / 176 ° F (Stainless Steel [...]

  • Page 12

    10 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS192N Meter Body 1 1 / 2 in. NPT (Aluminum) 11 MS190N Meter Body 1 1 / 2 in. NPT (Stainless Steel) 11 MS192F Meter Body 1 1 / 2 in. ANSI 150 lb. Flange (Aluminum) 11 MS190F Meter Body 1 1 / 2 in. ANSI 150 lb. Flange (S/Steel) 21 u BS243[...]

  • Page 13

    11 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 10 to 250 / 2.6 to 66 Below 5 centipoise 15 to 235 / 4 to 62 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e ** 1800 kPa / 260 PSI / 18 Bar or Flange Rule Maximum Operating T emperature -10 ° C to +80 ° C (+14 ° F to +[...]

  • Page 14

    6 2 10 11 13 12 14 15 16 17 8 / 9 8A / 9A O-Ring Only 5 4 3 1 1 10 20 * * 7 5 12 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS520N Meter Body 2 in. NPT (Aluminum) 11 MS520-1N Meter Body 2 in. NPT (Stainless Steel) 11 MS483F Meter Body 2 in. ANSI 150 lb. Flange (Aluminum) 11 MS481F M[...]

  • Page 15

    13 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 15 to 350 / 3.96 to 92.46 Below 5 centipoise 30 to 300 / 7.93 to 79.25 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e ** 1800 kPa / 260 PSI / 18 Bar Operating T emperature Range -10 ° C to +80 ° C (+14 ° F to +176 ° [...]

  • Page 16

    [...]

  • Page 17

    [...]

  • Page 18

    [...]

  • Page 19

    [...]

  • Page 20

    M- 4103/ 04 05[...]