Go to page of
Similar user manuals
-
Blood Pressure Monitor
Omron Healthcare HEM-790IT
132 pages 6.99 mb -
Blood Pressure Monitor
Omron Healthcare HEM-7211-E
27 pages 1.09 mb -
Blood Pressure Monitor
Omron Healthcare HEM-780
104 pages 1.72 mb -
Blood Pressure Monitor
Omron Healthcare HEM-907
26 pages 0.61 mb -
Blood Pressure Monitor
Omron Healthcare 7300IT
92 pages 3.6 mb -
Blood Pressure Monitor
Omron Healthcare HEM-711DLX
72 pages 2.1 mb -
Blood Pressure Monitor
Omron Healthcare M3
38 pages 1.53 mb -
Blood Pressure Monitor
Omron Healthcare HEM-422CRLC
40 pages 0.81 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Omron Healthcare HEM-412C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron Healthcare HEM-412C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Omron Healthcare HEM-412C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Omron Healthcare HEM-412C should contain:
- informations concerning technical data of Omron Healthcare HEM-412C
- name of the manufacturer and a year of construction of the Omron Healthcare HEM-412C item
- rules of operation, control and maintenance of the Omron Healthcare HEM-412C item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron Healthcare HEM-412C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron Healthcare HEM-412C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron Healthcare service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron Healthcare HEM-412C.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron Healthcare HEM-412C item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
INSTRUCTION MANUAL MANUAL INFLA TION BLOOD PRESSURE MONITOR Model HEM-412C[...]
-
Page 2
2 Introduction ……………………………………………………………… 3 Know Y our Unit ………………………………………………………… 4 Quick Reference Guide …………………………………………………… 5 Battery Installation/Replacement ………………………………………… 6 How T [...]
-
Page 3
3 Thank you for purchasing the Omron HEM-412C Manual Inflation Blood Pressure Monitor . This easy-to-use monitor quickly detects your blood pressure and pulse measurements and displays them on a large, clear digital panel. Y our new HEM-412C uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood'[...]
-
Page 4
4 Diastolic Blood Pressur e /Pulse Display Systolic Blood Pressur e Display Air J ack Air T ube Air Inflation Bulb Air Release Button Cuff T ab Arm Cuff Air Plug (Connects to the air jack) On/Off Button KNOW YOUR UNIT[...]
-
Page 5
5 1. A void eating, smoking, and ex ercising for at least 30 minutes before taking a measurement. 2. Put your left arm through the cuff loop. The bottom of the cuff should be about 1/2'' abov e the elbow . The cuf f tab should lie ov er the brachial artery on the inside of the arm. 3. Pull the cuff so that it is tightened e venly around y[...]
-
Page 6
6 1. Slide the battery cov er off in the direction of the arrow . 2. Install 4 “ AA” size batteries so + (positiv e) and – (negativ e) polarities match the polarities of the battery compartment as indicated. 3. Replace the battery cov er . 4. If the Low Battery Indicator appears on the display , replace all four batteries. Long-life alkaline [...]
-
Page 7
7 HOW TO APPL Y THE ARM CUFF 1. Locate your brachial artery by pressing two f ingers approximately one inch abov e the elbow crease on the inside of the left arm. Determine where your pulse is strongest. 2. The cuff should be assembled correctly when it is remov ed from the box. If it is not, pass the end of the cuff furthest from the tubing throug[...]
-
Page 8
8 HOW TO APPL Y THE ARM CUFF 5. Pull the cuff so that the top and bottom edges are tightened ev enly around your arm. 6. When the cuff is positioned correctly , press the sewn hook material FIRML Y against the pile side of the cuff. 7. Make certain the cuf f fits snugly around your arm. The cuf f should make good contact with your skin. 8. Sit in a[...]
-
Page 9
9 HOW TO T AKE A READING 1. Press the On/Off b utton. a) All display symbols appear for about one second. This is the initial LCD T est. b) The display symbols disappear and the Deflation Indication Symbol ( ) starts to flash. c) When the monitor completes the necessary preparations before measurement, the Ready T o Measure Symbol ( ) appears next [...]
-
Page 10
6. When the Deflation Indication Symbol ( ) appears on the display , push the air release button to release any air left in the cuf f. NO TE: W ait 5-10 minutes before taking another blood pressure measurement. W aiting allows the engorged blood v essels to return to normal. Y ou may require more rest time between readings depending on your individ[...]
-
Page 11
11 To pr otect your monitor from damage, please do the f ollowing: • Do not subject your monitor to extreme temperatures, humidity , and direct sunlight. • Do not fold the cuff and tubing tightly . • Do not inflate the monitor ov er 280 mmHg. • Do not disassemble the monitor . • Do not subject the monitor to strong shocks (for example, dr[...]
-
Page 12
12 ERROR INDICA TORS Error Symbol Cause Correction If you continue to hav e diff iculty obtaining a reading, call OMRON HEAL THCARE CUSTOMER SER VICE TOLL FREE 1-800-634-4350 . Please tell the representati ve you hav e a Omron Model HEM-412C Manual Inflation Blood Pressure Monitor . Cuff under -inflated. W ait 10 minutes before taking another measu[...]
-
Page 13
13 NOTE: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product generates, uses[...]
-
Page 14
14 Model: HEM-412C Display: LCD digital display Measurement Range: Pressure: 0-280 mmHg Pulse: 40-200/min. Accuracy/Calibration: Pressure: ±3 mmHg or 2% of reading Pulse: ±5% of reading Inflation: Manual by inflation bulb Deflation: Automatic pressure release valv e Rapid Air Release: Push button v alve Pressure Detection: Capacitiv e pressure se[...]
-
Page 15
15 LIMITED ONE YEAR W ARRANTY Y our HEM-412C Manual Inflation Blood Pressure Monitor is warranted to be free from manufacturing defects for a period of one year under normal use. This w arranty e xtends only to the original retail purchaser . Should repair be needed within the warranty period, ship the unit prepaid to Omron Healthcar e, Inc., 300 L[...]
-
Page 16
Manufactured for: OMR ON HEAL THCARE, INC. 300 Lake view P arkway V ernon Hills, Illinois 60061 www .omronhealthcare.com Copyright © 2002 OMR ON HEAL THCARE, INC. HEM-412CINST Rev A F or Customer Service Call T oll Free 1-800-634-4350[...]