Omron Healthcare HEM-432C manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron Healthcare HEM-432C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron Healthcare HEM-432C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron Healthcare HEM-432C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron Healthcare HEM-432C should contain:
- informations concerning technical data of Omron Healthcare HEM-432C
- name of the manufacturer and a year of construction of the Omron Healthcare HEM-432C item
- rules of operation, control and maintenance of the Omron Healthcare HEM-432C item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron Healthcare HEM-432C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron Healthcare HEM-432C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron Healthcare service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron Healthcare HEM-432C.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron Healthcare HEM-432C item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INSTRUCTION MANUAL MANUAL INFLA TION BLOOD PRESSURE MONITOR Model HEM-432C R[...]

  • Page 2

    2 T ABLE OF CONTENTS Introduction …………………………………………………………… 3 Important Safety Notes ……………………………………………… 4 Know Y our Unit ……………………………………………………… 5 Quick Reference Guide ……………………………………………… 6 Bat[...]

  • Page 3

    3 INTRODUCTION Thank you for purchasing the Omron HEM-432C Manual Inflation Blood Pressure Monitor . Fill-in for future reference DA TE PURCHASED: ______________ SERIAL NUMBER: ________________ Staple your purchase receipt here. The monitor features an easy-to-squeeze inflation bulb that allo ws you to quickly inflate the cuff. The measurement read[...]

  • Page 4

    4 IMPORT ANT SAFETY NOTES To assur e the correct use of the pr oduct basic safety measures should always be followed including the pr ecautions listed below:  Read all information in the instruction book and any other literature included in the box before using the unit.  Contact your physician for specific information about your blood pressu[...]

  • Page 5

    5 KNOW YOUR UNIT Systolic Blood Pressure Display ON/Off Button Air Release Button Air Inflation Bulb Air Plug Air T ube (Connects to the air plug) Air T ube Arm Cuff Diastolic Blood Pressure / Pulse rate Display Air Plug Air T ube (Connects to the air plug) MEMORY Button[...]

  • Page 6

    6 QUICK REFERENCE GUIDE 1. Av oid eating, smoking, and exercising for at least 30 minutes before taking a measurement. 2. Put your left arm through the cuff loop. The bottom of the cuff should be about 1/2 inch abov e the elbow . The cuf f tab should lie ov er the brachial artery on the inside of the arm. 3. P ull the cuf f so that it is tightened [...]

  • Page 7

    7 BA TTER Y INST ALLA TION / REPLACEMENT 1. Slide the battery cov er off in the direction of the arrow . 2. Install 4 “ AA” size batteries so + (positiv e) and – (negati ve) polarities match the polarities of the battery compartment as indicated. 3. Replace the battery cov er . NO TE: If the Low Battery Indicator appears on the display , repl[...]

  • Page 8

    8 CARE AND MAINTENANCE To k eep your digital blood pressur e monitor in the best condition and pr otect the unit fr om damage follow the dir ections listed below: Clean the monitor with a soft dry cloth. Do not use any abrasi ve or v olatile cleaners. Do not attempt to clean the cuf f. Nev er immerse the monitor or any components in water . Store t[...]

  • Page 9

    9 HOW TO APPL Y THE ARM CUFF 1. If the cuff is assembled correctly , the se wn hook material will be on the outside of the cuff loop and the metal D-ring will not touch your skin. 2. P ass the end of the cuff furthest from the tubing through the metal D-ring to form a loop. The smooth cloth should be on the inside of the cuff loop. 3. Put your left[...]

  • Page 10

    10 HOW TO APPL Y THE ARM CUFF 4. Pull the cuff so that the top and bottom edges are tightened ev enly around your arm. 5. When the cuff is positioned correctly , press the sewn hook material FIRML Y against the pile side of the cuff. 6. Make certain the cuf f fits snugly around your arm. The cuff should mak e good contact with your skin. 7. Sit in [...]

  • Page 11

    11 HOW TO T AKE A MEASUREMENT Please read “How T o Apply The Arm Cuff” before taking a reading. 1. Press the ON/OFF Button. a) All display symbols appear for about one second. This is the initial LCD T est. b) The display symbols disappear and the Deflation Indication Symbol ( ) starts to flash. c) When the monitor completes the necessary prepa[...]

  • Page 12

    12 HOW TO T AKE A MEASUREMENT 3. Remain still. The cuff will begin to deflate automatically . 4. As the cuff deflates, decreasing numbers appear on the display . The Heart Symbol ( ) flashes at ev ery heartbeat. 5. When measurement is complete, the Heart Symbol ( ) stops flashing and your blood pressure and pulse rate are displayed alternately . 6.[...]

  • Page 13

    13 HOW TO USE THE MEMOR Y FUNCTION This monitor has a memory capable of storing fourteen (14) sets of readings. E v ery time you complete the measurement, the monitor automatically stores blood pressure and pulse rate. • Press the ON/Off Button. • Press the MEMOR Y Button to recall stored readings while the Heart Symbol ( ) is displayed. • Wh[...]

  • Page 14

    14 ERROR INDICA TORS Error Symbol Correction Cause Cuff under -inflated. Residual air pressure in cuff. Movement during Measurement No pulse or blood pressure reading due to very weak artery pulse. Cuff o ver-inflated (more than 300 mmHg). Batteries hav e run down. Press Air Release Button for 4-5 seconds to release air pressure in cuff. Carefully [...]

  • Page 15

    15 FCC ST A TEMENT Note: PO TENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The produc[...]

  • Page 16

    16 W ARRANTY INFORMA TION Y our HEM-432C Manual Blood Pressure Monitor , excluding the monitor cuff, is w arranted to be free from defects in materials and workmanship appearing within 1 year , when used in accordance with the instructions provided with the monitor . The monitor cuff is warranted to be free from defects in materials and workmanship[...]

  • Page 17

    17 SPECIFICA TIONS Model: HEM-432C Display: LCD Digital Display Measurement Range: Pressure: 0 to 280 mmHg Pulse: 40-180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Manual by inflation bulb Deflation: Automatic pressure release valv e Rapid Air Release: Push button v alve Pressure Detection: Capac[...]

  • Page 18

    18 NOTES[...]

  • Page 19

    19 NOTES[...]

  • Page 20

    Made in China Manufactured by: OMR ON HEAL THCARE, INC. 300 Lake view Parkw ay V ernon Hills, Illinois 60061 www .omronhealthcare.com Copyright © 2003 Omron Healthcare, Inc. 432CINST Rev A[...]