Go to page of
Similar user manuals
-
Blood Pressure Monitor
Omron Healthcare HXA-GCUFF-LLA
1 pages 0.62 mb -
Blood Pressure Monitor
Omron Healthcare HEM-790IT
132 pages 6.99 mb -
Blood Pressure Monitor
Omron Healthcare HEM-712C
40 pages 0.74 mb -
Blood Pressure Monitor
Omron Healthcare HEM-18
7 pages 0.44 mb -
Blood Pressure Monitor
Omron Healthcare HEM-757
20 pages 0.19 mb -
Blood Pressure Monitor
Omron Healthcare HEM-773AC
20 pages 0.65 mb -
Blood Pressure Monitor
Omron Healthcare BP760
44 pages 0.9 mb -
Blood Pressure Monitor
Omron Healthcare M3
38 pages 1.53 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Omron Healthcare HEM-7211-E8, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron Healthcare HEM-7211-E8 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Omron Healthcare HEM-7211-E8. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Omron Healthcare HEM-7211-E8 should contain:
- informations concerning technical data of Omron Healthcare HEM-7211-E8
- name of the manufacturer and a year of construction of the Omron Healthcare HEM-7211-E8 item
- rules of operation, control and maintenance of the Omron Healthcare HEM-7211-E8 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron Healthcare HEM-7211-E8 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron Healthcare HEM-7211-E8, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron Healthcare service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron Healthcare HEM-7211-E8.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron Healthcare HEM-7211-E8 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Check following components! Vérifier les composants suivants ! Prüfen Sie folgende T eile des Lieferumfangs! Controllare i componenti indicati di seguito! ¡Compruebe los siguientes componentes! Controleer de volgende onderdelen! Проверь те следующие ко мпоненты! HEM-721 1-E_B_M02_100928.pdf Manufacturer OMRON HEAL THC[...]
-
Page 2
Content s Thank you for purchasing the OMRON M6 Au tomatic Blood Pressure Monitor . The OMRON M6 is a compact, fu lly automatic blood pressur e monitor , operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly . For comfortable controlled in flation without the need of pressure pre-setting or re-i[...]
-
Page 3
1 EN Import ant Safety In formation Consult your doctor prior to using in pregnancy or if diagnosed with arrhyt hmia or arteriosclerosis. Please read t his section carefully b efore using the unit. War ni n g: • Indicates a pot entially hazardous situation which, if not avoided, could re sult in death or seriou s injury . (General Usage) • Alwa[...]
-
Page 4
2 Impor tant Safet y Inform ation (AC Adapter Usage) • Use only the original AC adapter (optional) designed f or this unit. Use of unsupported adapters may damage and/or may be hazardous to the unit. • Plug the AC adapter into the appropriate voltage outlet. Do not use a multiple-tap. • Do not use the AC adapter if the unit or the power cord [...]
-
Page 5
3 EN 1. Overview Main unit Display Memory button O/I ST ART ( ) button Up/Down ( ) buttons Date/T ime setting ( ) button Air Jack Battery compartment AC adapter jack (for optiona l AC adapter) Arm cuff Arm cuff (Medium cuf f: arm circumference 22-32cm ) Coloured Marker Air tube Air plug Display Date/T ime display Dual Check System Systolic blood pr[...]
-
Page 6
4 2. Prep aration 2.1 Inst alli ng/Replaci ng the Batteries 1. Remove the battery cover . 2. Insert four “AA” batteries as indicated in the battery comp artment and then replace the battery cover . Not es: • If the ba ttery low symb ol ( ) appea rs on the display , turn the unit of f then replace all bat teries at the same time. • The me as[...]
-
Page 7
5 2. Prep arat ion EN 2.2 Setting the Date and T ime 1. Pr ess th e butt on. 2. Set the monitor to t he correct date and t ime before t aking a measureme nt for the first time. 3. Press the O/I ST ART button to store the setting. Not es: • If the batteries have been removed for 30 seco nds or more, the date and time setting will need to be reset.[...]
-
Page 8
6 3. Using the Unit 3.1 Appl ying the Arm Cuff Remo ve tight-fi tting clo thing or tigh t rolled up sleeve f rom your u pper arm. Do no t place the c uff over thic k cloth es. 1. Insert the air plug into t he air j ack . 2. Put your arm through the cuff loop . 3. Position the arm correctly . The bottom edge of the cuff should be 1 to 2 cm above the[...]
-
Page 9
7 3. Using the Unit EN 3.2 How to Sit Correctly T o take a meas urement , you need to b e relaxed a nd comfor tably seated, u nder comfor table room temp erature. No b athing, dr inking alcohol or caffeine, smoki ng, exerci sing or eati ng 30 min utes befor e taking a meas urement. • Sit on a chair with your feet flat on the floor . • Sit uprig[...]
-
Page 10
8 3. Using the Unit 3.3 T aki ng a Readin g Not es: • T o cancel a mea surem ent, pr ess th e O/I ST ART b utton to turn the uni t of f and to rel ease t he air i n the arm cuf f. • Remain still while taking a measurement. 1. Press t he O/I ST ART button. The c uff will start to infl ate automa tically . If your sy stolic pressure is more than [...]
-
Page 11
9 3. Using the Unit EN Dual Check System Press the O/I ST ART button, then the Dual Check System lamp lights and the unit sta rts detecting a device error . If the unit is accurate and functioning correctly , the Du al Check System lamp remains lit dur ing the meas urement. If an error is detected , the Dua l Check System lamp flash es and “Er”[...]
-
Page 12
10 3. Using the Unit • Y our blood pr essure monitor includes an irregular heartbeat feature. Irregular heartbeats can influence the results of t he measur ement. The irregular heartbeat algorithm automatically determines if the m easurement is usable or needs to be repeat ed. If the measurement results are affected by irregular heartbeats but th[...]
-
Page 13
11 3. Using the Unit EN 3.4 Using the Memo ry Func tion The m onitor automa tically s tores the r esult up to 9 0 sets. It can also ca lculate an avera ge reading b ased on th e measurem ents from the las t three rea dings taken within 10 minutes . If there are only two readings i n memory fo r that peri od, the avera ge will be ba sed on two readi[...]
-
Page 14
12 3. Using the Unit T o V iew the Rea dings S tored in Memory 1. Press the button, while the aver age value is dis played. The M emory numbe r appears for a secon d before the pulse rate is di splayed . The newe st set i s numb ered “1” . 2. Press the or button to view the readings stored in memory . : T o the older read ings : T o the more re[...]
-
Page 15
13 EN 4. T roubl eshooting and Maintenance 4.1 The Ico ns and Error Mes sages Error Display Cause Remedy Irregular heartbeats are detected. Remove the arm cuff. W ait 2-3 minutes and then t ake another measureme nt. Repeat the steps in section 3.3. If this error continues to appear , contact your doctor . Movement durin g measurement. Carefully rea[...]
-
Page 16
14 4. Troub leshoot ing a nd Maint enance Air plug disconnected. Insert the plug securely . Refer to section 3. 1. Arm cuff not app lied correctly . Apply the arm cuff correctly . Refer to section 3. 1. Air is leaking from the arm cuff . Replace the cuf f with the new one. Refer to Chapter 5. Cuff over inflated. Repeat measurement. Remain still and[...]
-
Page 17
15 4. Troub leshoot ing a nd Maint enance EN 4.2 T roubles hooting Problem Cause Remedy The reading is extremely low (or high). Arm cuff not applied correctly . Apply the arm cuff correctly . Refer to section 3.1. Movement or talking during measurement. Remain still and do not talk during measurement. Refer to section 3.3. Clothing is interfering w[...]
-
Page 18
16 4. Troub leshoot ing a nd Maint enance Nothing happens when you pres s the buttons. The batteries are empty . Replace the batteries with new ones. Refer to section 2.1. The batteries have been inserted incorrectly . Insert the batteries wi th the corr ect (+/-) polarity . Refer to section 2.1. Other problems. • Press t he O/I ST AR T button a [...]
-
Page 19
17 4. Troub leshoot ing a nd Maint enance EN 4.3 Maintenance T o protec t your uni t from damage , please o bserve the following: • Do not subject the main unit and the cuf f to extreme te mperatures, humidity , moisture or direct sunlight. • Do not fold the cuff or tubing tightly . • Do not disassemble the unit. • Do not subject the unit t[...]
-
Page 20
18 4. Troub leshoot ing a nd Maint enance 4.4 St or a ge Keep th e unit in i ts storage ca se when no t in use. 1. Unplug th e air plu g from the air j ack. 2. Gently fold the air tube into the arm cuff. Not e: Do not bend the air tube excessively . 3. Place t he arm cuff and main unit in the storage case. Do no t store the u nit in the following s[...]
-
Page 21
19 EN 5. Optional Part s Using th e Optional AC Adapter 1. Insert the AC ada pter plug into the AC adapter jack on the rear s ide of the main unit . 2. Plug the AC adapter into an electrical outlet. T o disc onnect the AC adapter , unplu g the AC ada pter from th e electric al outlet first and then remove the AC adap ter plug from the main unit. Me[...]
-
Page 22
20 6. T echnical Dat a Note: Subject to technical modification without prior noti ce. Pro duct D escr iptio n Autom atic Blood Pressure Monitor Model O MRON M6 (HEM -721 1-E / HEM-72 1 1-E8) Display LCD Digital Display Meas urement Method Oscillometric me thod Measure ment R ange Pres sure : 0 to 299 m mHg Puls e: 40 to 1 80/min. Accuracy P ressure[...]
-
Page 23
21 6. Techni cal Data EN • This dev ice ful fils the p rovision s of EC di rectiv e 93/42/EE C (Medic al Device Directi ve). • This bloo d pressure monitor is des igned accordi ng to the Euro pean S t andard E N1060, Non- invasiv e sphygmom anomete rs Part 1: Ge neral Re quirements and Part 3: S upplementary requir ements for electromec hanical[...]
-
Page 24
22 6. Techni cal Data Import ant in formation re garding Electro Magnetic Com p atibility (EM C) With the increased num ber of electronic devices such as PC’s and m obile (cellular) telephones, medical devic es in use may be suscep tible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect opera[...]
-
Page 25
23 EN 7. Some Useful In formati on about Bl ood Pressur e What is Blood Pressure? Blood pres sure is a measure of the forc e of blood flowing ag ainst the walls of t he arteries. Arterial blood pres sure is c onstantly chan ging durin g the cours e of the hea rt’s cycle. The hig hest press ure in the c ycle is called th e Systol ic Bl ood Pressur[...]
-
Page 26
24 7. Some Useful In formation a bout B lood Pre ssure Why is it a Good Thing to me asure Blood Pressure at Home? Many fac tors such as phys ical acti vity , anxiety , or the time of day , ca n influ ence your blood pr essure. A singl e measur ement may not be sufficient for an accu rate diagnos is. Thus it is best to try and measure you r blood p [...]
-
Page 27
25 7. Some Useful In formation a bout B lood Pre ssure EN Classification of Blood P ressure by the Wo rld Health Organiza tion The World Hea lth Organi zation ( WHO) and th e Internati onal So ciety o f Hype rtensio n (ISH) d eveloped the Bloo d Pressure C lassificatio n shown in thi s figure. This cl assificati on is ba sed on the blood pressure v[...]