A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron Healthcare HEM-907, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron Healthcare HEM-907 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron Healthcare HEM-907. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron Healthcare HEM-907 should contain:
- informations concerning technical data of Omron Healthcare HEM-907
- name of the manufacturer and a year of construction of the Omron Healthcare HEM-907 item
- rules of operation, control and maintenance of the Omron Healthcare HEM-907 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron Healthcare HEM-907 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron Healthcare HEM-907, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron Healthcare service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron Healthcare HEM-907.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron Healthcare HEM-907 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 INS TR U CTION MAN U AL OMR ON Digital Automatic Blood P ressure Mon itor Model HEM - 9 0 7 HID E P - SE T 1 00 AU T O 1 40 1 80 220 260 280 MOD E A VG. M AN U . CHE CK SI N G LE O N / OF F A V G . / 1 s t / 2 n d / 3 r d D E F L A T I O N STA RT STO P mm Hg SYS mmHg DIA BPM PU L SE A RT . INDEX M A X Tha nk yo u very much for pu rchas ing the OM[...]

  • Page 2

    2 Intended Us e Medical P urpose This i s a medical de vice that meas ures the bra chial blood pressu re in a non-inv asiv e mann er . Intended Us er Legally c er ti ed : such as d octor , nu rse and med ic al e xpert. Pa tien t Popu lation It is us ed on adult p atien ts only . En vir onment The inst rument is used in physicians ’ of  ce s[...]

  • Page 3

    3 E x emptions OM RON will not be ar any responsibilitie s on t he following mat ters. When a p roblem or d amage occu rs c au sed by th e main ten ance an d/or r epai r c on- du cted b y a person oth er tha n OM RON or th e deale r speci ed b y OMR ON The prob lem or da mage o f O MRON pr oduct caused b y the p roduct of o ther ma nu- fact urer[...]

  • Page 4

    4 Names and F unctions of the P ar ts HIDE P - SET 10 0 AUTO 14 0 18 0 220 260 280 MODE A VG. MANU. CHECK SINGLE ON/OFF A V G . / 1 s t / 2 n d / 3 r d D E F L A T I O N START ST OP mmHg SYS mmHg DIA BPM PULSE AC DC8V 1 . L CD display 2. HID E ( non- display ) Button 3. DC jack 4 . P- SET (press ure setting ) V olume 5. MO DE Selector 1 0 . ST OP B[...]

  • Page 5

    5 Ba t tery lev el Displays for the usable level. Displays for the l ow level. Displays for the unusable level. Names and F unctions of the P ar ts Displa y HIDE BPM mmHg PULSE SYS mmHg DIA AC Systolic blood pressure Dias tolic b lood pressure Con ten ts when the A V G. Mode is selected A VG. : Mean value 1 st : First me asurement 2nd : Sec ond mea[...]

  • Page 6

    6 Names and F unctions of the P ar ts Explanation of F unct ions ( 1 ) P ressure sett ing function P - SET In ation c an be set by AUT O (automatic set ting ) or th e target value. A UTO ( automatic setting) : In the SIN GLE (single measurement ), A VG. ( av erage ), and MA NU. ( auscult ation ) Mo des, the monitor est imates the systolic blo od[...]

  • Page 7

    7 Names and F unctions of the P ar ts ( 4) Set ting mo de ch ange func ti on Y o u can set th e number of times to m easure, the waiting ti me until the st ar t of measurem ent, and the inter val bet ween measurements. It em s to se t Set va lu e F 1 Number of measurem ents 2 times, 3 t imes F2 W aitin g time until t he star t of m easurement 0 sec[...]

  • Page 8

    8 Notes on S afet y The war ning signs and the sample ic ons show n here are listed for you to use t he product s afely and cor rect ly as well as to prevent the risk and the damag e to you and others f rom happening. The ic ons and meanings are as follow. Warning sign Contents Warning Indicates mat ter s in which deat h or sever bodily damage may [...]

  • Page 9

    9 Notes on S afet y Caution When you are n ot going to use t he unit for a long p eri od of time, be sure to remove the AC adapter from the electric outlet. Y ou may suf fer elect ric shoc k, or electr ic leak or  re may arise beca use of deter iorated insulation. Be sure to remove the AC adapter from the elec tr i c outlet w hen installing, rem[...]

  • Page 10

    10 Notes on S afet y Caution Be sure to use the p ower supply of 23 0 V AC. It may cause  re or electr ic shock. Do not share an elect ric outl et with other unit or elec tric applianc e. It may c ause  re or electric leak. Do not pull the p ower co rd when pulling out the AC adapter fro m the elect ric out let. The power c ord will be disc o[...]

  • Page 11

    11 Notes on S afet y Maintenance Be sure to inspec t the unit on regular basis. Check ac curac y on a 1 year inter val. If the unit has not be en used for a while, be sure to c on rm t hat the unit oper ates nor mally and safely before us e Durabilit y The durabilit y of thi s unit is  ve y ear s. (Ar m cuf f is a c onsumable. ) Me asur es t [...]

  • Page 12

    12 Components of the P roduct Main unit Access ories HIDE P - S E T 10 0 A U TO 14 0 1 80 2 2 0 260 280 MODE AVG . MA N U . C HE C K S IN G L E ON/OFF A V G . / 1 s t / 2 n d / 3 r d D E F L A T I O N START STOP Medium size ar m cuf f ( with built- in air bag ) Model : HE M -9CMC Ar t.no. : 492864 0 - 0 Applic able ar m circumferenc e: 22 to 32 cm [...]

  • Page 13

    13 Sel ec t th e ar m cu f f ac cor din g to t he ar m c ircu mf ere nce o f th e pat ie nt . Ar m circumferenc e Name of the ar m cuf f 1 7 - 22 cm 22 - 32 c m 32 - 42 cm Small size adult arm c uf f ( option ) Adult arm c uf f Larg e size adult arm cu f f ( opti on ) Be sure to use the ar m cuf f suitable for the size of the pat ient ’ s arm. If[...]

  • Page 14

    14 Ho w to Apply the Ar m C uf f (c o n t .) R A N G E ART . RA N G E A R T. INDE X 22 ~ 32cm ( 9" ~ 13" ) R EF HEM - CR 19 Adju st t he l evel of t he a rm c uf f t o th e leve l of th e he ar t. Keep the level of the arm c uf f at the s ame level as the hear t dur ing the measure - ment. Ho w to use the P ow er So urce (A C ad apt er ex[...]

  • Page 15

    15 Ho w to Measure B lood P ress ure Warning If any abnormal mat ter oc curs dur ing the me a- surement such as t he in ation does not sto p , remove the arm c uf f or pull the air tub e from t he main unit.  Y ou may suf fer per ipheral neuropathy . Requests from OMRON  Be sure that the patient should n ot touch the unit.  Be sure to m[...]

  • Page 16

    16 Ho w to Meas ure Blood P ress ure (in SI NGLE M ode) Wrap t h e ar m cuf f ov e r th e patient’s ar m. 1. Set t he M OD E Sel ec to r to “SINGLE” . 3. ON/OFF A V G . / 1 s t / 2 n d / 3 r d D E F L A T I O N START STOP HIDE P - SET 100 AUTO 140 18 0 220 260 280 MODE AVG. MANU. CHECK SINGLE Push t he ST ART B ut to n to st ar t the meas ure[...]

  • Page 17

    17 Wrap t h e ar m cuf f ov e r th e patient’s ar m. 1. Set t he M OD E Sel ec to r to “AV G . ”. 3. ON/OFF A V G . / 1 s t / 2 n d / 3 r d D E F L A T I O N START STOP HIDE P - SET 100 AUTO 140 18 0 220 260 280 MODE AVG. MANU. CHECK SINGLE Push t he ST ART B ut to n to st ar t the meas urement. Set the unit to th e star t t ime of the  rs[...]

  • Page 18

    18 Ho w to Meas ure Blood P ress ure (in MA NU. Mode) Wrap t h e ar m cuf f ov e r th e patient’s ar m. 1. Push t he O N/OFF (p owe r) But t on to t ur n on t he pow er . 3. ON/OFF A V G . / 1 s t / 2 n d / 3 r d D E F L A T I O N START STOP HIDE P - SET 100 AUTO 140 18 0 220 260 280 MODE AVG. MANU. CHECK SINGLE Set t he P- S ET (pr es sure s et-[...]

  • Page 19

    19 Ho w to Meas ure Blood P ress ure (in CHECK M od e) Disp lay of pre ssure c an b e con r me d by the CH ECK Mode (yea rly p roc edur e ). Wha t you nee d to pre pare ( 1 ) Well- adjusted reference pre ssure monitor (inc luding rubber ball), (2 ) T -shaped tub e, (3 ) T wo r ubber tubes, and (4 ) something in th e cylindr ical shape to w rap t[...]

  • Page 20

    20 Installation and R eplacement of Ba t t er y Pa ck Rem ove the b at t er y c over on t he b ack o f th e main unit. Installation: T o install the bat ter y pack, c onnec t the bat ter y pack c onnec tor to the c onnecto r in the bat ter y cover . Replacement: Remove the batter y pac k fro m the co nnector and replac e wit h a new one. In sta ll [...]

  • Page 21

    21 Cle an th e bl ood p re ssur e mon it or ,t he cu f f an d th e ca bl es usi ng a cl ot h da mp ene d wi th wa te r ,dilu te d disinfectant alcohol or diluted mild detergent. T o disinfect, wipe t he unit with a s of t clot h squeezed well af ter moistened w ith the foll owing disinfect ant. Benzalkonium c hlor ide 0.01 - 0.2 w/ v% Chlor hexizin[...]

  • Page 22

    22 L ist o f Error C odes Erro r cod e Cause How to co rre ct Er1 In at ion erro r When the pre ssure does n ot ex ce ed 1 5 mmHg af ter oper ating a pump for 15 se conds from t he star t of in ati on When th e in ation does not re ach the set pressure of th e arm cu f f within the sp eci ed time after starting the in ation • • I[...]

  • Page 23

    23 If a t roubl e occur s whil e using th e unit , pl ease che ck th e followin g. Proble m Wha t to inspe ct How to co rre ct The unit in ates to abnor mally high (low) pressure. Is the ar m cuf f w rapped c or rec tly ? Wrap the arm c uf f c orrec tly , and measure again. Is the patient m oving his/ her arm or b ody during in ati on ? Ask t[...]

  • Page 24

    24 Speci  cati on s Name : OM RON Di gital Automat ic Bloo d Pressure M onitor H EM - 907 Model : HEM- 907 - E / HEM- 907 - E7 Display : Digita l display Measurement : Osc illometr ic method Measurement Range : Pressure; 0 to 29 9 mmHg Pulse rate: 30 to 199 beat s/min Acc uracy : Pressure; Within +/- 3 mmHg Pulse rate; Within +/- 5% of reading I[...]

  • Page 25

    25 Manufacturer OMRON HEAL THC ARE Co., L td. 53, K unots ubo , T era do - cho , Muk o , K y ot o, 6 1 7 - 00 02 JAP A N EU- representative OMRON HEAL THCARE EUR OPE B. V . Scorpiu s 33, 2 1 3 2 LR Hoo fddo r p , THE NETHE RL A NDS w w w .omr o n - h e al th c a re.c om Production facilit y OMR ON HEAL THC ARE Co. , Ltd. Mie , JAP A N Subs idiar y [...]

  • Page 26

    26 Englis h Im po r t ant i nf or ma ti on r eg ar di ng E le ct ro M ag net ic C om pa ti bi li ty ( E MC ) Wi th t he in cre as ed nu mbe r of el ec tr oni c dev ic es su ch as P C. s and m obi le ( c ellular) telephones, medic al devices in use may be susc eptible to electromagnetic interference from other de vices. Electromagnetic interfer- enc[...]