A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron Healthcare NE-U17, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron Healthcare NE-U17 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron Healthcare NE-U17. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron Healthcare NE-U17 should contain:
- informations concerning technical data of Omron Healthcare NE-U17
- name of the manufacturer and a year of construction of the Omron Healthcare NE-U17 item
- rules of operation, control and maintenance of the Omron Healthcare NE-U17 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron Healthcare NE-U17 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron Healthcare NE-U17, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron Healthcare service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron Healthcare NE-U17.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron Healthcare NE-U17 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OMRON UL TRA SONIC NEBULISER Model NE-U1 7 Instruction Man ual ■ Thank y ou very much f or purchasing this OMRON Ultrasonic Neb uliser . ■ Be sure to read this instruction manual carefully bef ore using the unit so that y ou can use it saf ely and correctly . ■ Please k eep this instr uction man ual alwa ys at hand f or future ref erence. U l[...]

  • Page 2

    1 1 Ex emptions fr om Liabilities Please understand that OMRON is not liab le for the f ollowing: 1. Occurrence of trouble and/or damage caused by the maintenance and/or repair conducted by other than OMR ON or OMRON’ s authorized dealer . 2. T roub le and/or damage of OMRON’ s product caused by the product of other man uf acturer not deliv ere[...]

  • Page 3

    2 Intended Use Medical Pur pose This product is intended to be used f or inhaling medication f or respirator y disorders or f or humidification in combination with o xygen therap y . Intended User • Legally cer tified medical e xper ts, such as doctor , nurse and therapist, or healthcare personnel or patient under the guidance of qualified medica[...]

  • Page 4

    3 Examples of signs The icon indicates caution (including warning and danger). Matters inv olving actual caution are indicated by statements or pictures in or near . Notes on Saf ety ■ The warning signs and the sample icons shown here are listed f or you to use this product saf ely and correctly as well as to pre vent the risk of injur y to y ou [...]

  • Page 5

    4 Notes on Saf ety If the nebulisation parts have already become dirty before using the unit, clean them first bef ore use. • If the medication remains in the neb ulisation unit, your ph ysical conditions may change f or the worse. W ash off the remaining medication in the par ts thoroughly with water after cleaning these parts with disinf ectant[...]

  • Page 6

    5 Notes on Saf ety General Advice Do not use the unit f or the pur pose other than f or inhalation. Do not use any par ts other than the accessories or the optional par ts listed on page 22. Do not fill the medication cup with more than 150 ml medication or less than 5 ml. • The unit ma y not nebulise. Do not mov e the unit while medication remai[...]

  • Page 7

    6 Features of the Pr oduct About the principle of neb ulisation in the NE-U17 ➀ The NE-U17 tr ansmits the energy of ultrasonic vibration from the vibrator located at the bottom of the water tank into w ater . ➁ The ultr asonic vibration is transmitted to the medication in the medication cup through the water in the w ater tank. ➂ The ultr aso[...]

  • Page 8

    7 Composition of the Pr oduct U ltraso n ic Neb u liser NE-U17 AIR-FLOW V OLUME NE BU L ISA T IO N V OLUM E T IM ER (MIN ) W A TER L EVEL MED IC AT IO N CUP COVER FAN COV ER TIMER POWER CONT INUOUS CONT IN U OUS ST AR T/ ST OP Main unit Mouthpiece set Inhalation hose (M) with a cuff , 70 cm T w o medication cups P ower cord – As the unit is a Cla[...]

  • Page 9

    8 Names of the P ar ts water level Ultrasonic Nebul is er NE-U17 A IR-F LOW V OLUME NEBU LI SA T IO N V O LU M E TIMER(MIN ) W AT ER LEV EL M ED ICA TIO N CU P CO V ER FA N CO V ER TIMER POWER CONTI NUOUS CO N TINUOUS START/ STOP Neb ulisation unit Medication cup cov er Air duct cov er Handle Displa y P ower lamp Timer knob Medication cup cov er fi[...]

  • Page 10

    9 Ho w to Prepare the Unit bef ore Inhalation – Clean the par ts bef ore star ting the inhalation. [P ar ts that can be disinfected b y boiling] (F or the disinfecting method, ref er to Page 17.) [P ar ts that cannot be disinfected b y boiling] (F or the care and disinfection, ref er to Page 17.) Submerge these par ts in a container filled with s[...]

  • Page 11

    10 Ho w to Prepare the Unit bef ore Inhalation 2 Filling medication into the medication cup. 1) Remo ve the medication cup cover b y rotating it counter cloc kwise . 2) Fill medication into the medication cup. 3) Assemble the medication cup co ver b y turning it cloc kwise , then install it to the main unit. Maximum of 150 ml 1 2 3 Assembling and a[...]

  • Page 12

    11 Ho w to Inhale 1 Setting the inhalation time. 16 min. 18 min. 21 min. 23 min. 26 min. 28 min. CONTINUOUS TIMER(MIN) TIMER CONTINUOUS CONTINUOUS TIMER(MIN) TIMER CONTINUOUS CONTINUOUS 2 Push the ST ART/ST OP Button ( ). The fan will r otate and the unit star ts to neb ulise . When the timer is used: The displa y counts down b y 1 minute . T o cha[...]

  • Page 13

    12 Ho w to Inhale 3 Inhaling the aerosol. <Example of correct use> Y ou can use an optional inhalation mask instead of a mouthpiece. In the f ollowing cases, the b uzzer sounds and the unit stops operation. • When the time set b y the timer is completed • When the medication cup cov er is remov ed during inhalation • When the amount of [...]

  • Page 14

    13 Ho w to Inhale (Using Optional P ar ts) 1 Using the unit for a long time By using the optional “long time nebulisation set (4997217-7)” and the “supply medication set (4997206-1)”, the unit can nebulise contin uously for a long time . ➀ Remov e the medication cup cov er of the main unit. Attach an optional long time nebulisation set in[...]

  • Page 15

    14 Ho w to Inhale (Using Optional P ar ts) Having passed through a bacterial filter , the filtered air can be supplied to the inside of the long time nebulisation set. ➀ Remov e the medication cup cov er and assemble the long time nebulisation set with the main unit. T o assemb le, use the long time neb ulisation set in place of the medication cu[...]

  • Page 16

    15 Ho w to T ake Care of the Unit How to T ake Care of the P ar ts 1 T ur n off the po wer b y pushing the ON/ OFF Button ( ), and unplug th e pow er plug from the electric outlet. 2 Remov e the mouthpiece set, or inhalation mask. 3 Rotate the medication cup cov er-fixing le ver cloc kwise. 4 Remov e the nebulisation unit f or disassembling. 5 Disc[...]

  • Page 17

    16 Ho w to T ake Care of the Unit How to T ake Care of the Air Filter Replace the air filter when it becomes dir ty . ➀ Remo ve the neb ulisation unit from the main de vice. ➁ Remo ve the f an cover b y lifting it up. ➂ Remo ve the air filter case from inside the f an cov er . ➃ Remo ve the air filter from the air filter case to replace wit[...]

  • Page 18

    17 Ho w to Disinfect the Unit Ho w to Disinfect the Unit Disinf ection by boiling cannot be done to some par ts . They ma y become deformed. Disinfection b y disinfectant Diff erent disinf ectants hav e different anti-bacterial actions. F or ster ilization and disinf ection, follo w the instruction manual and the notes on each disinf ectant. The ti[...]

  • Page 19

    18 Ho w to Disinfect and Store the Unit Sterilization with eth ylene o xide gas (E.O .G.) Obser v e the Instruction Manual of the ster iliz er and consult with the manuf acturer of the E.O .G. ster ilizer f or the details . Some of the rubber and plastic par ts of the nebuliser ma y hav e residual eth ylene o xide gas. After sterilization, consult [...]

  • Page 20

    19 T r oub leshooting T r ouble The pow er lamp does not illuminate. The unit does not nebulise . The nebulisation rate is lo w . The nebulisation pow er is lowered. Nebulisation is unstable . Where to Inspect Is the pow er plug securely plugged into the electric outlet? Is ➀ of ERR OR displa y flashing due to insufficient amount of water in the [...]

  • Page 21

    20 Specifications T echnical data Product name : Omron Ultrasonic Neb uliser Model : NE-U17 (NE-U17-E) P ower source : 230 V A C , 50 Hz P ower consumption : Appro x. 80 V A Fuse : T2A L250V Ultrasonic frequency : Appro x. 1.7 MHz P ar ticle size : * MMAD 4.4 µm (MMAD=Mass Median Aerodynamic Diameter) Nebulisation r ate : ** Appro x. 0 to 3 ml adj[...]

  • Page 22

    21 Specifications Important information regarding Electr o Magnetic Compatibility (EMC) With the increased number of electronic de vices such as PC’ s and mobile (cellular) telephones, medical devices in use ma y be susceptible to electromagnetic interf erence from other de vices. Electromagnetic interference ma y result in incorrect operation of[...]

  • Page 23

    22 List of Optional P ar ts – Materials are indicated by abbre viations. ABS : Acrylonitr ile-butadiene-eth ylene resin EV A : Eth ylene vinyl acetic acid resin PMP : Polymeth yle pentane PP : P olypropylene resin PS : P olyeth ylene resin SEBS : Styrene elastomer Medication cup (4997211-8) Used to transmit the ultrasonic vibration. (If it has an[...]

  • Page 24

    Manufacturer OMR ON HEAL THCARE Co., Ltd. 24, Y amanouchi Y amanoshita-cho , Ukyo-ku, K yoto , 615-0084 JAP AN EU-representative OMRON HEAL THCARE EUROPE B.V . Kruisweg 577, 2132 NA Hoofddorp , THE NETHERLANDS www .omron-healthcare.com Production facility OMRON MA TSUSAKA Co., Ltd. 1855-370, K ubo-cho , Matsusaka-city , Mie-pref ecture 515-8503, Ja[...]