Go to page of
Similar user manuals
-
Blood Pressure Monitor
Omron Healthcare BP652
30 pages 4.88 mb -
Blood Pressure Monitor
Omron Healthcare HEM-609
48 pages 1.09 mb -
Blood Pressure Monitor
Omron Healthcare HXA-GCUFF-LLA
1 pages 0.62 mb -
Blood Pressure Monitor
Omron Healthcare HEM-790IT
132 pages 6.99 mb -
Blood Pressure Monitor
Omron Healthcare IM-HMS-HEM-SOFT-IT2-A-06-11/2011
30 pages 1.62 mb -
Blood Pressure Monitor
Omron Healthcare HEM-432C
20 pages 0.22 mb -
Blood Pressure Monitor
Omron Healthcare MX3 Plus
12 pages 0.35 mb -
Blood Pressure Monitor
Omron Healthcare HEM-907
26 pages 0.61 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Omron Healthcare RX3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron Healthcare RX3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Omron Healthcare RX3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Omron Healthcare RX3 should contain:
- informations concerning technical data of Omron Healthcare RX3
- name of the manufacturer and a year of construction of the Omron Healthcare RX3 item
- rules of operation, control and maintenance of the Omron Healthcare RX3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron Healthcare RX3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron Healthcare RX3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron Healthcare service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron Healthcare RX3.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron Healthcare RX3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 RX3 Plus English The OMRON RX3 Plus measures your blood pr essure and pulse simply and quickly from the wrist, without the use of an inflation bulb or stethoscope. The measur ement values are stor ed in the memory of the OMRON RX3 Plus. The OMRON RX3 Plus fits wrist circumfer ences from 13.5 to 19.5 cm. Introduction 24031904 RX3 Plus GB 1-18 3/25[...]
-
Page 2
Instruction manual page 1 RX3 Plus Digital Automatic Blood Pressure Monitor 24031904 RX3 Plus Cover 3/22/04 10:17 AM Pagina 1[...]
-
Page 3
2 RX3 Plus English T able of contents 1 How to obtain meaningful blood pressur e readings 3 2 Overview 4 3 Preparation 5 3.1 Insert batteries 5 3.2 Fit wrist cuff 6 4 Operation 7 4.1 Control functions 7 4.2 Set date and time 8 4.3 Measurement 9 4.4 Read display 10 5 Memory 11 5.1 Recall average value 11 5.2 Recall previous values 11 5.3 Erase memor[...]
-
Page 4
3 RX3 Plus English General • The OMRON RX3 Plus is not suitable for measuring the frequency of cardiac pacemakers. • Consult your doctor during pregnancy , arrhythmia and arteriosclerosis. • Avoid eating, drinking (alcohol), smoking, sport and taking a bath befor e measurement. • Be calm and relaxed befor e and during measurement. • Y ou [...]
-
Page 5
4 RX3 Plus English 2 Overview A Display B W rist Cuf f C Set button D Adjust button E Memory button F On/of f button G Battery Compartment A F E D G C B 24031904 RX3 Plus GB 1-18 3/25/04 12:32 PM Pagina 4[...]
-
Page 6
5 RX3 Plus English 3 Preparation 1 Open the battery compartment. 2 Insert two batteries in the battery compartment. Caution ! Use two identical 1.5V alkaline batteries type AAA! 3 Close the battery compartment. 3.1 Insert batteries 24031904 RX3 Plus GB 1-18 3/25/04 12:32 PM Pagina 5[...]
-
Page 7
6 RX3 Plus English 3.2 Fit wrist cuff Caution ! Do not press on/of f button when the wrist cuff is not wrapped around the wrist! S Y S mmH g D I Am m H g P UL S E / m i n M A D JU S T S E T DATE/ TI M E SET SYSmmHg DIAmmHg PULSE/ m i n M A DJUS T S E T DATE/ TI ME SET SYSm m Hg DI AmmH g P ULS E /m in M A D JU S T S E T D A TE /TIME S E T 1 Bare yo[...]
-
Page 8
7 RX3 Plus English SYSmmHg DIAmm Hg P ULSE/min M ADJUST S ET DA TE/TIME SET C D E F H K J P L Q M N T R S 4 Operation C Set button D Adjust button E Memory button F On/of f button H Date. J Systolic blood pr essur e in mmHg. K Diastolic blood pressur e in mmHg. L Memor y display: 21 values in memory . M Average value of the latest 3 measurements di[...]
-
Page 9
8 RX3 Plus English 3 Press set button to pr oceed to month setting. Press adjust button to set the current month. 4 Press set button to pr oceed to day setting. Press adjust button to set the current day . 4.2 Set date and time Note : each time you press adjust button year (2001-2030), month (1-12), day (1-31), hour (0-23) and minutes (0-59) advanc[...]
-
Page 10
9 RX3 Plus English 5 Press set button to pr oceed to hour setting. Press adjust button to set the current hour . 6 Press set button to pr oceed to minute setting and press adjust button to set the current minutes. SYSmmHg DIAmm Hg P ULSE/min M ADJUST S ET DA TE/TIME SET SYSmmHg DIAmm Hg P ULSE/min M ADJUST S ET DA TE/TIME SET SYSmmHg D IA mmHg PULS[...]
-
Page 11
10 RX3 Plus English SYSmmHg DIAmm Hg P ULSE/min M ADJUST S ET DA TE/TIME SET 2 Press on/of f button to start measurement. The OMRON RX3 Plus measures during inflation! Caution ! Sit still, do not move, do not speak and do not touch the OMRON RX3 Plus! 4.4 Read display 1 Read the values of blood pr essur e and pulse from the display . No te : displa[...]
-
Page 12
11 RX3 Plus English 5 Memory L M SYSmmHg DIAmm Hg P ULSE/min M ADJUST S ET DA TE/TIME SET S YSmmHg DIAmm Hg PULSE/min M ADJUST S ET DA TE/TIME SET 5.1 Recall average value H/Q Date/time of measur ement. 1 Press memory button for latest and pr evious values. Pr ess on/of f button to tur n off power . Note : display shows alternately date, blood pres[...]
-
Page 13
12 RX3 Plus English 1 Press memory button to turn on power . 2 Press memory button and simultaneously on/off button to erase memory . Caution ! All stored values will be erased! P ress on/of f button to turn off power . SYSmmHg D IA mmHg P ULSE/min M ADJUST S ET DA TE/TIME SET SYSmmHg DIAmm Hg P ULSE/min M ADJUST S ET DATE/TIME SET 5.3 Erase memory[...]
-
Page 14
13 RX3 Plus English 6 Storage Display empty Fault Cause Rectification Correct r eading not possible Movement, sound vibration, weak pulse W ait for at least thr ee minutes to repeat measurement Low voltage Batteries weak/exhausted Fit two new identical 1.5V alkaline batteries type AAA Inexplicable values Wr ong working method Follow instructions, r[...]
-
Page 15
14 RX3 Plus English 8 Maintenance and spare parts Cleaning instruction • Use a soft, slightly moistened cloth to clean the OMRON RX3 Plus and the wrist cuff. Caution ! Do not use petrol, thinners or similar solvents! Caution ! Do not wash the wrist cuff! • Do not carry out repairs of any kind yourself. If a defect occurs consult your OMRON reta[...]
-
Page 16
15 RX3 Plus English Product name OMRON Digital Blood Pressure Monitor Model RX3 Plus Display Digital LCD Measurement range Pressure: 0 - 299 mmHg / Pulse: 40 - 180 /minute Accurac y Pressure: ± 3 mmHg / Pulse: ± 5% of display r eading Inflation Automatic by elect ric pump Deflation Automatic rapid deflation system Pressure detection Electrostatic[...]
-
Page 17
16 RX3 Plus English Blood circulation The blood circulation is r esponsible for supplying the body with oxygen. Blood pressur e is the pressur e exerted on the arteries. The systolic blood pressur e value (higher pressur e or top value)repr esents the blood pressur e produced by contraction of the heart muscle. The diastolic blood pressur e value ([...]
-
Page 18
17 RX3 Plus English Hypertension accelerates arterial sclerosis which can lead to very serious conditions such as stroke and myocar dial infarction. For these r easons it is very important to know whether the blood pressur e is within a healthy range. Blood pressur e fluctuates from minute to minute, thr oughout the day . Therefore it is essential [...]
-
Page 19
T reatment of high blood pr essure If your blood pr essur e reaches upper values of 140 - 160 mmHg and lower values of 90 - 95 mmHg in repeated measur ements over several days, you should consult your doctor for detailed medical examination. Y ou can assist the tr eatment pr escribed by your doctor in the following ways: • Loose weight and lower [...]