Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Omron NE-C30-E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron NE-C30-E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Omron NE-C30-E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Omron NE-C30-E should contain:
- informations concerning technical data of Omron NE-C30-E
- name of the manufacturer and a year of construction of the Omron NE-C30-E item
- rules of operation, control and maintenance of the Omron NE-C30-E item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron NE-C30-E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron NE-C30-E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron NE-C30-E.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron NE-C30-E item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Compressor Nebuliser Model NE-C30-E • Instruction Manual • Mode d’em ploi • Gebrauchsanweisu ng • Manuale di ist ruzioni • Manual de instruccion es • Gebruiksaanwijzin g • РУК ОВОДСТВ О ПО ЭКСПЛУ А Т АЦИИ TM 3 5 IM-NE- C30-E -06-11/2 011 1657682- 9F EN FR DE IT ES NL AR RU NE-C30_main.book Page 1 Tuesday, De[...]
-
Page 2
2 Before using the unit Contents Befo re using th e unit Introduction ............ ................... ............. ............. ................... ............. .......... 3 Intended use ................. ............. ............. ................... ............. ................... .... 3 Importan t safety instructions... ............. ....[...]
-
Page 3
3 EN Introduction Thank you for p urchasing the OMRO N Comp Air Elite. This pr oduct was develope d in conj unction with resp iratory th erapis ts for the succe ssful treatmen t of asthma, chr onic bronchi tis, aller gies and othe r respirato ry disord ers. T he compr essor for ces air to the neb uliser . When th e air ent ers the nebulis er , it c[...]
-
Page 4
4 Import ant safety inst ructions Read all the inform ation in the instruct ion manual and any other literat ure in clude d in the box before using the device. When us ing an electrica l product, espec ially when childr en are pres ent, ba sic safety p recauti ons shou ld alw ays be fo llowed incl uding the f ollowing: W a rning: Indicate s a poten[...]
-
Page 5
5 Important safety in struct ions EN • Do not use th e main uni t, AC adapt er , o ptional r echarg eable batte ry , or opti onal battery charger while they are wet, o r connec t them to a pow er outlet or other devic es with wet hands . • The compresso r , AC adapt er , and optiona l recharge able batter y and charger are not water proof. Do n[...]
-
Page 6
6 Importan t safety i nstructions • Do not leav e the unit u nattende d with infa nts or person s who c annot ex press thei r cons ent. • Do n ot su bject t he devi ce or the parts to any s trong s hocks s uch as droppi ng the device on the flo or . • Do not disto rt the va poriser h ead, or j ab the noz zle of the medicati on tank with a pin[...]
-
Page 7
7 Important safety in struct ions EN General Safe ty Precautions: • Insp ect the dev ice and parts before usin g them eac h time, an d check that the re are no problems. In particula r , be sure to check th e followi ng: - That th e vapo riser head, n ozzle o r air tube a re not dam aged. - That th e nozzle i s not block ed. - That th e com press[...]
-
Page 8
8 1. Know your unit A. Compressor (M ain Unit) A1. Power Ind icator A2. Power Switch A3. Charge Indicator A4. Air Connector A5. Filter Cover (* Air filter inside.) A6. Nebuliser Kit Holder A7. AC Adapter J ack A8. Battery C onnector B. Air T ube (PVC, 20 7cm) B1. Air Plug B2. Air Plug C. Nebulising Parts D. Inhalatio n Attac hment s D1. Mout hpiece[...]
-
Page 9
9 1. Know your unit EN Accessories Material of att achment • Also applicable Section 10. Optional part s and accessories. F . S pare Air Filters x 5 G . AC Adapter G1. Power Connector G2. Power Co rd H. Carrying Bag I. Instructi on Manual J. W arranty Card Nebuliser Kit, Mouthpiece, Nosepiece, Adapter for Child Mask (SEBS): Polypropylene Adult Ma[...]
-
Page 10
10 2. Guide to using the Comp Air E lite Prep aring the Nebuliser for Use (Section 3) Note: Clean an d disinf ect the nebulis er kit a nd applic able inh alatio n att achm ent s bef ore us ing t he de vice f or th e fir st ti me, or if i t has not been us ed for mo re than on e week. T aking Medication (Sect ion 4) Notes: • Do not ti lt the nebu [...]
-
Page 11
11 EN Operat ing in structi ons 3. Prep aring the nebuliser for use W a rning: Clean and disinfect the nebuliser kit, mout hpiece and optional nosepiece or masks be fore using them for the first time after purchase, if the devic e has not been used for a long pe riod of time, or if more than one person uses th e same dev ice. For direc tions on c l[...]
-
Page 12
12 3. Preparin g the n ebuliser for use 3.2 Adding medication and ass embling the p a rt s 1. Remo ve the mou thpiece a nd cap from the nebu lise r kit. 2. Remo ve the inh alation to p from the medic ation tan k. 1) Rotate the inh alatio n top anti-c lockwis e. 2) Lift the inha lation top out of th e medi cation tan k. 3. Remo ve the vapo rise r he[...]
-
Page 13
13 3. Preparing the nebul iser for us e EN 5. Reattach the va poriser h ead to t he medica tion tan k. 6. Put the inhala tion top ba ck ins ide the medic ation tank. 1) Align the p rotrus ion on the inhalatio n top with the i ndent on th e medi cation tank, as shown. 2) Rotate the inhal ation to p clockwis e and alig n with the m edicatio n tank un[...]
-
Page 14
14 3. Preparin g the n ebuliser for use Attaching the child ma sk (PVC) Attach the mask to the inhalat ion top. 1) Attach the c ap to the i nhalat ion air inl et. 2) Attach the c hild mas k to the i nhalatio n top. Attaching the nosepiece Attach the cap whe n using t he nosepi ece. 1) Attach the c ap to the i nhalat ion air inl et. 2) Attach the n [...]
-
Page 15
15 3. Preparing the nebul iser for us e EN 8. Attach the air tube. 1) Attach the air tub e to the ai r connector o n the comp ressor . 2) Attach the o ther end o f the air tube to t he air tube c onnector on the medica tion tank. Not es: • Make sur e that the air t ube is s ecurely attached to th e comp ressor ( main unit) and nebulis er kit, and[...]
-
Page 16
16 4. T aking medication 1. Hold the nebul iser kit a s indic ated on the right. Caution: Do not tilt the nebulise r kit so that it is at an angle of greater than 45°. M edi cati on ma y flo w in to the mouth. 2. Press the powe r switch . The c ompressor starts and neb ulisation sta rts. Not es: • The green lig ht shows th at the p ower is on. ?[...]
-
Page 17
17 4. Tak ing me dica tion EN 3. Inhale m edic ation accor ding to y our doc tor ’s and/or he alth c are advi ser ’s instruct ions. Using the mouthpiece Prepare your mo uthpiece accord ing to Section 3 .2.7. Inser t the mouthp iece into your mo uth and inhale the med ication breathing no rmally . Exhale a s normal through the mou thpiece. Using[...]
-
Page 18
18 4. Takin g medica tion 4. When trea tment is com plete, turn th e power off. Check tha t there is no conden satio n or mois ture in the air tu be and unplug the device from the power out let. W arning: Condensation may occur in the ai r tube. Do not store the air tub e while it cont ains condensation or moisture. This could result in infect ion [...]
-
Page 19
19 EN Care and mainte nance 5. Cleaning and daily disinfecting 5.1 Cleani ng Follow ing the cleanin g instru ction s after each use will preven t any re mainin g medicat ion in t he tank from dr ying, re sulting i n the dev ice not ne bulisin g effectively and als o for preve nting infe ctions. W a rning: Thoroughly rinse the nebuliser and the mask[...]
-
Page 20
20 5. Clea ning and daily di sinfec ting 6. After cleani ng and disinfecti ng the parts, rins e them thor oughly with c lean water a nd allow th e parts to air dr y in a cl ean en vironment. 7. If th e compre ssor is dirty , w ipe it cl ean with a soft cloth moistened wi th water or m ild deter gent. Caution: The compressor is not wate rproo f. 8. [...]
-
Page 21
21 5. Cle aning and daily di sinfecti ng EN Handling t he V aporiser Head The vapor iser head i s an imp ortant part that is u sed to va porise medication. Be sure to obser ve the fol lowing pr ecautio ns when handling it. Caut ion: • Alway s wash the vapori ser head a f ter eac h use. Failu re to d o so could c ause b lockages and a deterioratio[...]
-
Page 22
22 6. Maintenance and storage T o keep your de vice in the bes t cond ition and prote ct the dev ice fro m damag e foll ow th ese d irec tions : Caution: • Do not leave the unit unattended with infants or persons who cannot expres s their con sent. • Do not subject the device or th e p arts to a ny strong shocks such as dropping the device on t[...]
-
Page 23
23 EN 7. Changing the air fi lter On ave rage, the air fil ter sho uld be ch anged every 60 days or so, or when the filter has cha nged col our from white. 1. Pull th e ai r fil ter cov er of f the comp resso r . 2. Chan ge the air fi lter . Remo ve the old air filter with a shar p obje ct, such as a toothp ick, and insert the new air filte r . 3. [...]
-
Page 24
24 8. T roubleshooting Check th e followin g if your unit sh ould fa il during o perat ion. Y ou can al so refer to the pages of this m anual f or compl ete in structi ons. Symptom Cause Remedy Nothin g happens when th e power s witch is p ressed. (The powe r indi cat or do es not ligh t.) Is the AC ada pter connec ted correctl y to the an electric[...]
-
Page 25
25 8. Troub leshooti ng EN Notes: • If the sugge sted rem edy does not so lve the pr oblem, d o not try to repair th e devic e - no parts of t he unit are user s ervic eable. Return the u nit to a n authorized O MRON retail outle t or distribu tor . • The device should b e servic ed once a year by an appro ved OMRO N servic e centre . The d evi[...]
-
Page 26
26 9. T echnical dat a Notes: • Subject to technical modification without prior notice. • This OMRON product is produc ed under the s trict quality sys tem of OMRON Healt hcare Co. Ltd., Japan. • The device may not work if t he temperature and voltage conditions are different to those defined in the specifications. Name: Comp Air Elite Model:[...]
-
Page 27
27 9. Tech nical data EN T echnical data fo r the OMRON Comp Ai r compr essor with t he OMR ON V .V .T . (Virtua l V alve T echnology) Nebuliser kit: Notes: • Per formanc e may va ry with d rugs su ch as suspen sions or h igh v iscosity . Se e drug s upplier ’s data sheet for further details. • The data above is referenc ed by Om ron Heal thc[...]
-
Page 28
28 9. Te chnica l da ta Notes: • Do not use th e devic e where it may be ex pose d to flamma ble ga s. • This device fulfils t he provi sions o f the EC directiv e 93/42/ EEC (Med ical Dev ice Directiv e) and th e Europe an S tandard EN13 544-1:200 7, Respir atory th erapy equipme nt - Par t1: Nebuli zing sy stems an d their com ponents. = T yp[...]
-
Page 29
29 9. Tech nical data EN Corr ect D isposal of T his Produ ct (Wa ste Elec trical & El ectronic Equi pment ) This ma rking sho wn on th e product or its literatur e, in dicates that it sho uld not be disposed of, with other hou sehold wa stes at the end o f its worki ng life. T o prevent possible h arm to the environ ment or h uman he alth from[...]
-
Page 30
30 10. Optional p art s and acce ssories OMRON V .V .T . Ne bul iser Kit Se t Orde r No . 99562 68-9 Air T u be (P VC, 207cm) Orde r No. 9956 270-0 Mout hpiece Order N o. 99562 73-5 Air T ube (Silic on, 100cm ) Orde r No. 9956 269-7 Nose pie ce Order N o. 99562 74-3 Ch ild M as k (SE B S) Se t Orde r No . 99562 81-6 Adult M ask (SEB S) Orde r No. 9[...]
-
Page 31
31 10. Op tional par ts and accessorie s EN Filt er Co ver Order No.9 956638-2 Instruc tion Manu al Orde r No.9956 633-1 Car rying B ag Order N o.99566 31-5 Ba ttery Set Includes the recharge able battery , battery ch arger . Order No.9 986453-7 Rech argeab le Battery Orde r No.9986 457-0 Batter y Ch arger Order N o.99864 61-8 AC Adap ter Order No.[...]
-
Page 32
32 1 1. Using optional acce ssories 1 1.1 Using the optional recharge able battery Use the r echargea ble batter y as shown i n the cha rt below . For details, ref er to the followin g pages. Using the battery for the first time. When the b atter y has not been used for a while. Fully ch arge the b attery . Att ach the batte ry to the main u nit an[...]
-
Page 33
33 11. Us ing option al acces sories EN 1. Charge the batt ery . 1) Insert the powe r connecto r of th e AC adapte r into the AC adapter jack on the c harger . 2) Plug the AC adapter i nto a power o utlet. Import ant notes on using the optional rechargeabl e battery • Char ge the batt ery befo re usin g it for th e first t ime. The batt ery is no[...]
-
Page 34
34 11. Us ing option al acce ssorie s 3) Attach the o ptional batter y to the charg er . Align the conne ctors on th e battery and charger , and press the battery un til it clicks into plac e. Charg ing st arts a nd the green cha rging indi cator blinks. 2. After the b attery is f ully charged , remove the batter y from th e charger . The gree n ch[...]
-
Page 35
35 11. Us ing option al acces sories EN When battery power is low The ch arge ind icator on th e main unit will light when battery power is low. Please note the followin g poin ts about usin g the de vice after the charge indicato r lights: • S top using the devi ce when the charge indicato r comes o n. • Batte ry power i s low and the device w[...]
-
Page 36
36 11. Us ing option al acce ssorie s Made in Ch ina Manufacturer OMRON HEAL THCARE Co., Ltd. 53, Kunot subo, T era do-cho, Muk o, Kyoto, 617-0002 JAP AN EU-r epr esen tative OM RON HEAL THCARE EUROPE B.V . Scorpius 33, 2132 L R Hoofddo rp THE NETHERLANDS www .omr on-h ealt hcare .co m Production facility OMRON (DALIAN) CO., L TD. Dalian, CHINA Sub[...]