A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron R3-1 Plus, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron R3-1 Plus one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron R3-1 Plus. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron R3-1 Plus should contain:
- informations concerning technical data of Omron R3-1 Plus
- name of the manufacturer and a year of construction of the Omron R3-1 Plus item
- rules of operation, control and maintenance of the Omron R3-1 Plus item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron R3-1 Plus alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron R3-1 Plus, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron R3-1 Plus.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron R3-1 Plus item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EN FR DE IT ES NL • Instruction Manual • Mode d’emploi • Gebrauchsanweisu ng • Manuale di istruzion i • Manual de instrucci ones • Gebruiksaanwijzin g • РУ КОВОД С ТВО ПО ЭК СПЛУ А Т АЦИИ RU AR Wr ist Blood Pressure Monitor Model R3-I Plus IM-HEM- 6022-E -02-08/08 5320469- 9B HEM6022-E.book Page 1 Thursday, [...]

  • Page 2

    2 Contents Befo re using t he uni t Introduction ................. ................... ............ 3 Important Safety Information ............... ..... 4 1. Ove rview ................. ............. .................. 6 2. Preparation ................................ ............ 8 2.1 Inst alling/Re placing the Batterie s .. ..... 8 2.2 Setti ng [...]

  • Page 3

    3 EN EN Introduction Thank you for purchasing the OMRON R3-I Plus Wrist Blood Pressure M onitor . This remarka ble, compact and easy t o use instrument is ideal for people who frequently m onitor their own blood pressur e. The small, pre-formed wrist cuff is very convenient and easy to apply . With a push of a button t he OMRON Wrist Blood Pressure[...]

  • Page 4

    4 Import a nt Safety Information Consult your docto r during pregnancy , arr hythmia and arteriosclerosis. People with poor peripheral circulation may find that results for measurements taken at the wrist vary from those taken on the upper arm. Please read this sect ion carefully before using the unit. Wa r n i n g : Indicates a potentially hazardo[...]

  • Page 5

    5 Importan t Safety Information EN • Do not use a mobile phone, or other devices t hat emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit. • Do not operate unit in a moving vehicle (car , airplane). (Battery Usage) • If battery fluid should get on your skin or cl othing, immediately rinse with plent[...]

  • Page 6

    6 1. Overview Mai n Unit A. Display B. Battery compartment cover C. W ri st cu f f D. MEM (Mem ory) button E. O/I ST ART butt on F . SET button A B C D E F HEM6022-E.book Page 6 Thursday, August 21, 2008 7:54 PM[...]

  • Page 7

    7 1.Overview EN Display Package Content s G . Systolic blood pressure H. Diastolic blood pressure I. Average value symbol (Displayed when viewing value for the last three measurements.) J. Memory v alue symbol (Displayed when viewing values stored in m emory) K. Irregular heartbeat symbol L. Battery low symbol M. Heartbeat symbol 1. Flashes during [...]

  • Page 8

    8 2. Prep aration 2.1 Inst alling/Repla cing the Batteries 1. Remove th e battery compartment cover by pulling it off in the direction of the arrow . 1) Grasp both ends of the battery cover. 2) Pull the cover off the main unit. 2. Insert two identical 1.5V “AAA” alkaline (LR03) batteries in the battery compartment. Make sure their polarity (+/-[...]

  • Page 9

    9 2.Prep aration EN 3. Put the battery cover back in place. Note: Be su re to set the date and time after installing or replacing the batteries. Refer to “2.2 Setting the Date and T ime”. The measurement values continue to be stored in memory e ven after the batteries are r eplaced. Battery Life & Replacement If the battery low symbol ( ) a[...]

  • Page 10

    10 2.Prep aration 2.2 Setting the Date and T ime Y our blood pressure m onitor aut omatically stores up to 60 measurement values in its memory and calculates an average value based on the three most recent measurements taken within 10 minutes of t he last reading. (If there are only two readings in memory f or that period, the average will be based[...]

  • Page 11

    11 2.Prep aration EN 4. Repeat steps 2 and 3 to set the month and day . 5. Repeat steps 2 and 3 to set the hour and minutes for the time. After all settings are completed the display may still be flashing. T o confirm settings and sh ut of f the unit press O/I ST ART button. Note: The unit will automatically turn itself of f after you press the SET[...]

  • Page 12

    12 3. Using the Uni t 3.1 Applying the Wris t Cuff Y ou can take a measurement on eit her your left or right wrist. Notes: • Y ou ca n take a measurement on either your left or right wr ist. The blood pressure can differ between your right and left wrist and therefore also the measured blood pressure values can be different. Omron recommends to a[...]

  • Page 13

    13 3.Using the Unit EN 2. Hold the bottom part of the wrist cuff and wrap i t around the wrist while pulling so that it fits comfortably . Note: Unless the wrist cuff is wrapped securely around the wrist, it m ay not be possible to take corr ect measurements. Smooth the cuff with your fingers to ensure that it fits snugly around the wrist. Notes: ?[...]

  • Page 14

    14 3.Using the Unit T aking a reading on the right wrist Measurements can also be made on the right wrist. Fit the unit on the right wrist as shown. HEM6022-E.book Page 14 Thursday, August 21, 2008 7:54 PM[...]

  • Page 15

    15 3.Using the Unit EN 3.2 Correct P osture Correct posture during measurem ent helps you get accurate results. Y ou should also try to measure y our blood pressure at the same time each day . Notes: • Do not take mea surements aft er bathing, drinking alcohol, smoking, exercising or eating. • Do not move or talk during measurement. Position yo[...]

  • Page 16

    16 3.Using the Unit 3.3 T aking a Re ading 1. Press the O /I ST ART button t o start measurement. The wrist cuf f will s tart to inflate automatically after the power is turned on. 2. After the unit has det ected your blood pressure and pulse rate, the cuff automatically deflates an d your blood press ure and pulse rate are displayed. Notes: • Si[...]

  • Page 17

    17 3.Using the Unit EN 3. Check the measurement result. The unit automatically stores blood press ure and pulse rate into it s memory . Refer to “3.4 Using the Memor y Function”. The time and date of the measurement are displayed alternately . 4. Undo the fast ener and remove the unit. 5. Press the O /I ST ART button to t urn off the unit. If y[...]

  • Page 18

    18 3.Using the Unit Symbol Informati on: • If your s ystolic or diastolic pressure is outside the standard range, the Heartbeat symbol ( ) will blink when the measurement result is displayed. Recent research suggests that the fol lowing values can be us ed as a guide to high blood pressure for measurements taken at home. This criteria is f or hom[...]

  • Page 19

    19 3.Using the Unit EN What is Irregular Heart beat? An irregular heart beat is a heartbeat rhythm that varies by m ore than 25% from the average heartbeat rhythm detected w hile the unit is meas uring the systolic and dias tolic blood pressure. If such an irregular rhythm is detected more than twice during measurem ent, the Irr egular heartbeat sy[...]

  • Page 20

    20 3.Using the Unit 3.4 Using the Memory Function This unit has a memory capable of storing 60 sets of readings. Every time you complete the measurement, the unit automatically stores blood pressure and pulse rate. If there are three readings withi n 10 minutes of the last reading, the average of the three readings is displayed. (If there are only [...]

  • Page 21

    21 3.Using the Unit EN T o Vi ew Previous Readings S tored i n Memory 1. Press the M EM button, while the aver age reading is displayed, to view readings stored in memory from the most rec ent to the oldest. Press the M EM button repeatedly to cycle through the readings. Note: The date and time of stored readings will be alternately displayed. 2. P[...]

  • Page 22

    22 3.Using the Unit 3. Press the O /I ST ART button t o turn the unit of f. Note: If you forget to turn the unit off, it will automatically shut itself off aft er two minutes . T o Delete Al l V alues in Mem ory Y ou c annot delete the stored readings partially , all the reading in the unit will be deleted. T o delete stored readings, first press t[...]

  • Page 23

    23 EN EN 4. Quick Reference Gui de Use this as a quick reference gui de only . If you are using this device for the first time, please read carefully Chapter 3 of this Instruction Manual. Avoid eating, drinking, smoking, or exercising for at least 30 minutes before taking a measurement. Y ou should also try to measure your blood pressure at the sam[...]

  • Page 24

    24 5. Han dli ng Erro rs a nd Prob lem s 5.1 Error Messages Error Symbol Cause Correction Cuff over inflated. Repea t measure ment. Remain still and do not move durin g measure ment. (R efer to secti on 3.3.) Movemen t during measurem ent. The wrist cuff is not fasten ed securely . Carefu lly read a nd repeat the steps listed under sect ion 3.1. An[...]

  • Page 25

    25 5.Handling Errors and Problems EN 5.2 T roubleshooting Symptom C ause Correction The read ing is ext remely low (or high). Are you h olding the wrist cuf f at heart level? Measure while in the correct posture. ( Refer to section 3.2.) Is the cuff wrapped sn ugly around th e wrist? Wrap the cuff correctly . (Refer to section 3.1.) Are your arms a[...]

  • Page 26

    26 5.Hand ling Errors and Pr oblems The bloo d pre ssur e is dif ferent ea ch t ime. The read in g is ex tr emely low (or h igh) . Blood pressur e read in gs constantly vary with time of measur ement an d nervous co ndition. T ake deep bre aths to relax before ta king a measur ement. The unit loses power during me asuremen t. The batte ries are emp[...]

  • Page 27

    27 EN EN 6. Maintenan ce and Storage T o protect you r unit from dam age, please avoid the following: • Subjecting your unit to extrem e temperatures, humidity , or direct sunlight. • W ashing the cuff or exposing t he cuff or unit to water . • Disassembling the unit. • Subjecting the unit to strong s hocks or vibrations. Dropping the Unit.[...]

  • Page 28

    28 6.Main tenance a nd Stora ge Calibration an d Service • The accuracy of th is blood pressure m onitor has been carefully tested and is designed for a long service lif e. • It is generally re commended to have the unit inspected every two years to ensure correct functioning and accu racy . Please consult your authorised OM RON dealer or the O[...]

  • Page 29

    29 EN EN 7. T echnical Data Note: Subject to technical modification without prior notice. Produc t Descr iption Wrist Blood Pressure Mo nitor Model OMRON R3-I Pl us (HEM -6022-E ) Display LCD Digital Display Meas urement Oscillom etric method Meas urement Ra nge Pressure : 0 to 299 mmHg Pulse: 40 to 180 beats/min Memory 60 Measurem ents with da te [...]

  • Page 30

    30 7.Techni cal Dat a • This OMRON product is produced under the str ict quality system of OMRON Healthc are Co. Ltd., Japan. The Core comp onent for OMRON blood pressure monit ors, which is the Pressure Sensor , is produced i n Japan for assembly . • Disposal of this product and used batte ries should be carried out in accordance wit h the nat[...]

  • Page 31

    31 7.Tec hnical Data EN This marking shown on the product or its literature, indicates that it should not be disposed of, with other household wastes at the end of its working life. T o pre vent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsib[...]

  • Page 32

    32 8. Some Useful Infor mation about Blood Pressur e What is Bl ood Pressur e? Blood pressure is a measure of the force of bl ood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during t he course of the heart ’ s cycle. The highest pressure in the cycle is called the Systolic Blood Pressure ; the lowes t[...]

  • Page 33

    33 8.So me Us efu l Inf orm ati on ab out Bloo d Pr essu re EN Classific ation of B lood Pressu re by the World Heath Organization The World Health Organization (WHO) and the International Society of Hy pertension (ISH) developed t he Blood Pressure Classification shown in t his figure. This classification is based on the blood pressure val ues mea[...]

  • Page 34

    34 8.Some Useful In formation about Blo od Pressure Made in China Manufa ctur er OMRON HEAL THCA RE CO., L TD. 24, Y amanouch i Y ama noshita-cho, Ukyo-ku , Kyoto, 615 -0084, Japan EU- repr esentative OMRON HEAL THCA RE EUROPE B.V . Kruisweg 577, 2132 N A Hoofdd orp, The Neth erlands www .omro n-healthcar e.com Prod uction facility OMRON DALIAN CO.[...]