Go to page of
Similar user manuals
-
Blood Pressure Monitor
Oregon Scientific BPW128
15 pages 0.51 mb -
Blood Pressure Monitor
Oregon Scientific BPW120
121 pages 6.46 mb -
Blood Pressure Monitor
Oregon Scientific BPW221
13 pages 0.49 mb -
Blood Pressure Monitor
Oregon Scientific BPW129
13 pages 0.92 mb -
Blood Pressure Monitor
Oregon Scientific BPW211
15 pages 0.33 mb -
Blood Pressure Monitor
Oregon Scientific BPW810
20 pages 0.44 mb -
Blood Pressure Monitor
Oregon Scientific BPW810N
5 pages 1.77 mb -
Blood Pressure Monitor
Oregon Scientific BPW813
20 pages 0.94 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Oregon Scientific BPW128, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Oregon Scientific BPW128 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Oregon Scientific BPW128. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Oregon Scientific BPW128 should contain:
- informations concerning technical data of Oregon Scientific BPW128
- name of the manufacturer and a year of construction of the Oregon Scientific BPW128 item
- rules of operation, control and maintenance of the Oregon Scientific BPW128 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Oregon Scientific BPW128 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Oregon Scientific BPW128, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Oregon Scientific service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Oregon Scientific BPW128.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Oregon Scientific BPW128 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
GB 1 mmHg 60 80 100 120 140 160 180 200 220 / min 2 1 21.2 22.2 85 90 158 92 110 155 93 112 10:05 10:12 x x x x x x LOG BOOK : Age: Weight: kg/lbs[...]
-
Page 2
2 GB BOLD BOLD LEYENDA : - INCREMENTO RÁPIDO - DESTELLANDO - PULSAR BOTÓN - PULSAR MANTENER OPRIMIDO EL BOTÓN ES BOLD BOLD LEGEND : - FAST INCREMENT - FLASHING - PRESS BUTTON - PRESS AND HOLD BUTTON GB BOLD BOLD LEGENDE : - AUGMENTATON RAPIDE - CLIGNOTEMENT - APPUYER SUR LE BOUTON - APPUYER SANS LACHER SUR LE BOUTON F[...]
-
Page 3
GB 3 INFORMATION CONCERNING THE CE SYMBOL This device complies with the European regulations based on the Medical Products Code, and bears the CE mark “CE0123”. The device has been quality inspected according to EG guideline 93/42/EWG and tested in compliance to the EN1060-1 Non-invasive sphygmomanometers-Part 1, General requirements and EN1060[...]
-
Page 4
4 GB DESCRIPTION AND FUNCTION OF PARTS A. Liquid Crystal Display (LCD) and protective cover - Large easy-reading display - 5 functional symbols - Systolic [SYS/mmHg], Diastolic [DIA/mmHg], Mean [MAP/mmHg], Pulse [pul/min.]and date & time display. B. Battery compartment Houses two (2) LR03 /AAA/ UM4 size 1.5V batteries C. Button - For time adjus[...]
-
Page 5
GB 5 DISPLAY-SYMBOL DESCRIPTION Memory Mark Weak Battery Inflating Mark Air releasing Pulse Mark INSTALLING BATTERIES 1. Slide battery cover off. 2. Install batteries first. Ensure correct polarity. Battery Type: 2 Alkaline LR03 (AAA)size 3. Replace the cover. Replace the batteries if: 1. the weak battery mark appears in the display 2. nothing appe[...]
-
Page 6
6 GB PROPER EQUIPMENT SETUP 1. Remove all watches, jewelry, etc. prior to attaching the wrist monitor. Clothing sleeves should be rolled up and the cuff sh ould be wrapped on bare skin for correct measurements. 2. Apply cuff to left wrist with palm facing up. 3. Make sure the edge of the cuff is about 1 cm from the plam. 4. In order to ensure accur[...]
-
Page 7
GB 7 WHAT IS MEAN ARTERIAL PRESSURE (MAP) The Mean Arterial Pressure is the average pressure forcing blood through the arteries. It is not the average of the systolic and diastolic blood pressure. It corresponds to a state of balance between the compressive and expansive forces acting on the arterial wall when there is no distension of the arterial[...]
-
Page 8
8 GB MEASUREMENT With the individual in a sitting position and with the cuff attached as previously mentioned, a blood pressure reading can be obtained. Note: - For accurate pressure measurement, take blood-pressure readings in a seated position. Avoid leaning back while the measurement is being taken. - Ensure that the lower arm is raised so that [...]
-
Page 9
GB 9 HOW TO TAKE MEASUREMENT Refer to Fig1 Fig1 2sec Fig1[...]
-
Page 10
10 GB Note: 1. Remove all watches, jewelry, etc. prior to attaching the wrist monitor. Clothing sleeves should be rolled up and the cuff should be wrapped on bare skin for correct measurements. 2. Apply cuff to left wrist with palm facing up. 3. Make sure the edge of the cuff is about 1 cm from the plam. 4. In order to ensure accurate measurements,[...]
-
Page 11
GB 11 HOW TO SET THE TIME Refer to Fig3 Fig 3 mode[...]
-
Page 12
12 GB AUTOMATIC POWER OFF The device will automatically switch off after about 1 minute. However, to conserve battery power, press the button whe n finished to turn the unit off. ERROR MESSAGES Display Err 1 Err 2, 8, 12, 13, 14, 15 Err 3 Err 4 Err 5, 6, 7 Err 9, 10,11 Description Deflation period too long Incorrect measurement Cuff is not fastened[...]
-
Page 13
GB 13 SPECIFICATIONS Measuring method : Oscillometric / non-invasive Application : Adults Measurement location : Wrist section of lower arm Circumference (approx. ) 5.3"-7.7"(13.5-19.5cm) Pressure Measuring range : 30 - 280mmHg Pulse Measuring Range : 30 - 200 pulse/min Accuracy : (Pressure) +/- 3mmHg (Pulse) +/- 5% Operating environment [...]
-
Page 14
14 GB Should you require assistance regarding this product and its operation, please contact our Customer Care Department at 1-800-853-8883 or via email at helpme@oscientific.com. WARRANTY This product is warranted to be free of manufacturing defects for a period of 12 months from date of retail purchase. Defective product should be directed to the[...]
-
Page 15
GB 15 measurement again, ensure that the cuff is properly attached, the arm is in the proper position and that movement has been minimized during the measurement process. If the device does not function: - Check that the unit is on. After about 3 minutes of inactivity, the unit will automatically turn off. - Ensure that batteries are properly inser[...]