A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Oregon Scientific RMR182, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Oregon Scientific RMR182 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Oregon Scientific RMR182. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Oregon Scientific RMR182 should contain:
- informations concerning technical data of Oregon Scientific RMR182
- name of the manufacturer and a year of construction of the Oregon Scientific RMR182 item
- rules of operation, control and maintenance of the Oregon Scientific RMR182 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Oregon Scientific RMR182 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Oregon Scientific RMR182, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Oregon Scientific service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Oregon Scientific RMR182.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Oregon Scientific RMR182 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 EN Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock MODEL: RMR182 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RMR182 Multi- Channel In-Out Thermometer with 433MHz cable free sensor and radio-controlled calendar clock. The basic package comes with a main unit, which is the tempera- ture and calendar [...]
-
Page 2
EN 2 A FOUR-LINE LCD DISPLA Y Facilitates easy reading of remote and indoor temperatures and calendar clock B[ ] RADIO-RECEPTION SIGNAL Indicates the condition of radio reception C TEMPERA TURE TREND INDICA TOR Indicates the trend of temperature changes D[ ] BA TTERY -LOW INDICA TOR (REMOTE SENSOR) Activates when the remote-sensor battery is low E[[...]
-
Page 3
3 EN MAIN FEA TURES: REMOTE UNIT A LCD DISPLA Y Displays the current temperature monitored by the remote unit B LED INDICA TOR Flashes when the remote unit transmits a reading C ° C/ ° F SLIDE SWITCH Selects between Centigrade ( ° C) and Fahrenheit ( ° F) D CHANNEL SLIDE SWITCH Designates the remote unit Channel 1, Channel 2 or Channel 3 E RESE[...]
-
Page 4
EN 4 5. Replace the battery compartment door and secure its screws. Note that once a channel is assigned to a remote unit, you can only change it by removing the batteries or resetting the unit. BA TTER Y INST ALLA TION: MAIN UNIT 1. Gently lift the tab on the battery compartment door . 2. Install 2 alkaline batteries (UM-3 or “AA” size 1.5V) s[...]
-
Page 5
5 EN Remote unit W all-mount T able Stand THE RESET BUTT ON This button is only used when the unit is operating in an unfavorable way or malfunctioning. Use a blunt stylus to hold down the button. All settings will return to their default values. GETTING ST AR TED Once batteries are in place for the remote units, they will start transmitting temper[...]
-
Page 6
EN 6 If no signals are received, blanks " ---- " will be displayed and the kinetic wave icon will show " ". Press [CHANNEL] and [MEMOR Y] simultaneously to enforce another search for about 30 seconds. This is useful in synchronizing the transmission and reception of the remote and main units. Repeat this step whenever you find d[...]
-
Page 7
7 EN NOTE ON ° C AND ° F The unit of temperature display is selected with the ° C/ ° F slide switch. Select ° C for Centigrade or ° F for Fahrenheit. Note that the remote temperature display on the main unit is dominated by the selection on the ° C/ ° F slide switch of the main unit. Whatever the display units of the remote sensors are, the[...]
-
Page 8
EN 8 CALENDAR CLOCK DISPLA Y MODES The RMR182 supports four display modes in the sequence of: MODE 1. Local Time Hour , Minute, Second ---------------------------- Day , Month MODE 2. Local Time Hour , Minute, W eekday ------------------------------- Day , Month MODE 3. Local Time / Second Time-Zone T ime (local time) Hour , Minute, W eekday ------[...]
-
Page 9
9 EN If you wish to disable the auto-reception feature, press the button for three seconds. The radio reception signal will disappear . The unit will not respond to radio signals. To enable the feature again, press the button for three seconds. The radio reception signal will start blinking to initiate reception automatically . HOW T O SET THE CLOC[...]
-
Page 10
EN 10 When the alarm goes off the sound which will gradually increase in volume and repeating speed will be turned on for about 2 minutes unless the [( ( • ) )] or [AL ON/OFF] button is pressed to mute the alarm. PRECAUTIONS This product is engineered to give you years of satisfactory service if you handle it carefully . Here are a few precaution[...]
-
Page 11
11 EN SPECIFICA TIONS T emperature Measurement Main unit Indoor T emperature measurement Displayed IN temperature range : -9.9 ° C to +70.0 ° C 14.2 ° F to 158.0 ° F Proposed operating range : -5.0 ° C to +50.0 ° C 23.0 ° F to 122.0 ° F T emperature resolution : 0.1 ° C 0.2 ° F Remote T emperature measurement Displayed OUT temperature ran[...]
-
Page 12
EN 12 CAUTION - The content of this manual is subject to change without further notice. - Due to printing limitation, the displays shown in this manual may differ from the actual display . - The manufacturer and its suppliers held no responsibility to you or any other claim arising by using this product. - The contents of this manual may not be rep[...]
-
Page 13
13 EN EC-DECLARA TION OF CONFORMITY This product contains the approved transmitter module that com- plies with the essential requirements of Article 3 of the R&TTE 1999 / 5 / EC Directive, if used as intended and the following standards have been applied: Safety of information technology equipment (Article 3.1.a of the R&TTE Directive) Appl[...]
-
Page 14
EN 14 086-002217-141 © 2004 Oregon Scientific. All rights reserved. RMR182_EN 8/16/04, 2:58 PM 14[...]
-
Page 15
15 EN Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Cloc k Model : RMR182 User Manual RMR182_EN 8/16/04, 2:58 PM 15[...]